• 제목/요약/키워드: Polident

검색결과 10건 처리시간 0.021초

염화세틸피리디늄 계열 구강세정제의 가철성 교정장치에 대한 세정효과 (Clean effect of a cetylpyridinium chloride-based mouthwash on removable orthodontic appliances)

  • 하다슬;이경희
    • 한국치위생학회지
    • /
    • 제23권4호
    • /
    • pp.227-234
    • /
    • 2023
  • Objectives: Cetylpyridinium chloride CPC-based mouthwashes are well known to have no harmful ingredients in the mouth and can be used for a long time. The purpose of this study was to evaluate the effect of using CPC-based mouthwashes to suppress the biofilm formation and antibiotics for handling orthodontic appliances. Methods: To measure the antibacterial effect, Streptococcus mutans (S. mutans) cultured orthodontic appliances were precipitated in Gargreen and Polident for 5 minutes, incubated at 37℃ for 24 hours(h). In order to measure the biofilm removal effect, the degree of biofilm formation on the orthodontic appliances was stained with a methylene blue and the difference before and after was compared using image J software program (NIH Image J; NIH, Bethesda, MD). Results: The viability of S. mutans according to the concentration showed that Gargreen and Polident inhibited colony formation compared to the control, respectively (p<0.01). The degree of biofilm formation was significantly higher in the control, however both Gargreen and Polident significantly reduced it compared to the before and after condition on removable orthodontic appliances (p<0.01). Conclusions: This study suggests that the use of Gargreen, a cetylpyridinium chloride based oral cleaning cleanser, could be replaced by Polident for antibacterial effect and biofilm formation on removable orthodontic appliances.

Evaluation of antibacterial activity against Candida albicans according to the dosage of various denture cleansers

  • Bae, Cha-Hwan;Lim, Yun-Kyong;Kook, Joong-Ki;Son, Mee-Kyoung;Heo, Yu-Ri
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.100-106
    • /
    • 2021
  • PURPOSE. The purpose of this study is to compare the antibacterial activity of currently purchasable denture cleansers against Candida albicans. Materials and methods: This study used tablet-type denture cleansers, PolidentⓇ, CoolingdentⓇ and FittydentⓇ, along with liquid denture cleansers, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ. The antibacterial activities of denture cleansers were evaluated based on the number of C. albicans and concentrations of the denture cleansers. Results. In the 0.5 × 106 cfu/㎖ culture medium, the C. albicans' death rate of PolidentⓇ was significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ, and Apple vinegarⓇ(P<.05). In the 0.5 × 107 cfu/, the C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly lower than those of FittydentⓇ, HexamedineⓇ, ListerineⓇ and Apple vinegarⓇ(P<.05). The C. albicans' death rates of PolidentⓇ and CoolingdentⓇ were significantly decreased at 0.02 g and 0.01 g. The C. albicans' death rate of FittydentⓇ was significantly decreased at 0.005 g (P<.05). The C. albicans' death rate of HexamedineⓇ was significantly decreased at 1/16 dilution. The C. albicans' death rate of ListerineⓇ was decreased at 1/8 dilution, and the antibacterial activity of Apple vinegarⓇ was decreased at 1/4 dilution (P<.05). Conclusion. As the number of C. albicans increased, the antibacterial activities of the denture cleansers decrease. In the tablet-type denture cleanser, all denture cleansers showed 100% C. albicans' death rate when used at a dose of 1 tablet. One denture cleanser showed the same antibacterial effect with only 1/3 of a tablet. In the liquid type denture cleanser, the level of dilution required was different for each denture cleanser.

의치 세정제가 의치상용 레진과 이장용 레진의 결합강도에 미치는 영향 (The effect of denture cleansers on the bond strength of reline resin to denture base resin)

  • 최에스더;한민수;권은자
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.225-230
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the effect of denture cleansers on the flexural bond strength of heat curing denture base resin and reliners. Methods: The denture base resin was bonded to the reliners(vertex self curing, kooliner, rebase II) to make the specimen. The specimens were immersed in denture cleansers(Polident, Cleadent) and evaluated after 1week, 3week, 5weeks. After denture reliners were injected, flexural bond strength was measured. Results: The bond strength of denture base resin and vertex self curing resin as reliner was significantly decreased at 5 weeks in cleadent and polident(p<0.05). The bond strength of kooliner and rebase II was significantly decreased at 5 weeks in denture cleaners(p<0.05). Kooliner was significantly decreased at 3 and 5 weeks in polident and rebase II was significantly decreased at 3 and 5 weeks in all denture cleansers(p<0.05). Conclusion : The flexural strength between the denture base resin and the reliners decreased significantly as the treatment time increased.

수종 의치세정제의 세척 효과에 관한 주사전자현미경적 비교 연구 (The efficacy of denture cleansing agents: A scanning electron microscopic study)

  • 윤보혁;윤미정;허중보;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.57-64
    • /
    • 2011
  • 연구 목적: 증류수, 차아염소산나트륨 성분의 가정용 살균소독 표백제 그리고 국내에서 판매중인 세 가지 의치세정제의 세척 효과를 주사전자현미경적 관찰을 통해 상호 비교하였다. 연구 재료 및 방법: 부산대학교병원 치과보철과에서 총의치 또는 국소의치를 제작했거나 제작 중인 연구대상자 5명의 상, 하악 임시 의치 협면에 금속 원판 시편을 식립 하였다. 연구대상자로 하여금 48시간 동안 임시 의치를 장착하게 한 후 회수하여 다음과 같은 다섯 가지 (증류수, 차아염소산나트륨 희석용액, $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$) 중 하나의 세척 방법으로 실온에서 8시간 동안 세척하였다. 실험에는 직접 참가하지 않았으나 치과적 지식이 있는 10명의 panel을 구성하였고, panel은 한 부위에서 얻어졌으나 다섯 가지 서로 다른 방법으로 처리된 시편들의 세척도를 주사전자현미경 사진을 이용하여 평가하였으며, 깨끗한 순으로 1, 2, 3, 4, 5의 순위를 기록하게 하였다. 결과: 세척 효과는 차아염소산나트륨 희석용액, $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$, 증류수 순으로 우수하였으나 차아염소산나트륨 희석용액과 $Polident^{(R)}$, $Polident^{(R)}$$Cleadent^{(R)}e$ 그리고 $Bonyplus^{(R)}$와 증류수 사이에는 유의한 차이가 없었다 (P > .05). 차아염소산나트륨 희석용액으로 세척한 시편의 표면에서는 거의 모든 치태가 제거되었으나, 의치세정제의 경우에는 대부분 세척 후에도 잔류 치태를 관찰할 수 있었으며 축적된 치태가 두꺼울수록 남아있는 치태가 더 많았다. 차아염소산나트륨 희석용액 (0.08% 이상)은 비귀금속 시편의 표면 부식을 유발하였다. 결론: 적절한 화학적 세정제의 선택 사용은 신체장애가 있거나 고령인 의치 환자의 구강 위생 관리에 도움을 줄 수 있음을 알 수 있다. 그러나 알칼리성 과산화물 계열의 의치세정제의 경우 의치 세척 효과가 제한적이기 때문에 가능한 칫솔질과 병행하여 사용하는 것이 보다 바람직한 방법으로 생각된다.

의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구 (THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

구순암 환자에서의 의치접착제를 이용한 상악 총의치와 심한 치주 상태에서의 하악 이중관의치를 이용한 수복 증례 (Prosthetic treatment for patient with upper lip cancer and severe periodontitis: Maxillary complete denture with denture adhesive and mandibular double crown-retained removable partial denture)

  • 최현석;이청희;조진현
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.74-80
    • /
    • 2015
  • 구강암의 발생 시, 구순의 결손과 방사선치료에 의한 치주조직과 치경부우식증 등의 문제가 발생할 수 있다. ADI (Association of dental implantology)에 의하면 상 하악골에 대한 방사선치료가 최근에 시행되었을 경우 임플란트를 식립하는 것은 상대적 비적응증이 된다. 대부분의 경우 임플란트를 이용한 보철물의 제작이 어렵고 의치를 사용한 수복이 이루어지게 된다. 특히, 구강암 수술로 인한 구순결손은 의치의 유지에 심각한 영향을 주게 된다. 본 증례는 상순암을 가진 환자로 일차적으로 절제술을 시행하고, 이차적으로 방사선 치료가 정기적으로 이루어진 결과, 환자의 상악 치아들은 순차적으로 자연 발치되었고, 하악은 매우 불량한 치주상태를 나타내었다. 상악은 총의치에 의치접착제를 적용하여 구순결손에 의한 의치의 유지력 저하를 극복하였고, 하악에서는friction pin을 이용한 하악이중관의치가 2년 동안 성공적으로 사용되었다.

의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향 (THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN)

  • 김계순;정회열;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.

Effect of denture cleansers on Candida albicans biofilm formation over resilient liners

  • Huh, Jung-Bo;Lim, Younghun;Youn, Hye-In;Chang, Brian Myung;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.109-114
    • /
    • 2014
  • PURPOSE. The purpose of this study was to analyze the effect of denture cleansers on Candida albicans biofilm formation over resilient liners and to evaluate compatibility between resilient liners and denture cleansers. MATERIALS AND METHODS. Acrylic resin (Lucitone 199$^{(R)}$) and 3 resilient liners (COE-SOFT$^{TM}$, GC RELINE$^{TM}$ and SOFRELINER TOUGH TOUGH$^{(R)}$) were incubated in denture cleansers (Polident$^{(R)}$ and Cleadent$^{(R)}$) for 8 hours a day and in unstimulated saliva for 16 hours a day (n=25/gp) for 60 days. Two-way and three-way repeated measures ANOVA were performed to compare the surface roughness (Ra), pH and C. albicans binding level by radioisotope (${\alpha}$=0.05). The statistical significance of the relation between Ra and adhesion was evaluated by correlation analysis. RESULTS. The degree of Ra was significantly decreased in the following order: COE-SOFT$^{TM}$, acrylic resin, GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. The immersion in denture cleansers significantly increased Ra of resilient liners, except for SOFRELINER TOUGH$^{(R)}$ in Cleadent$^{(R)}$. No significant differences in pH curves were observed among groups immersed in distilled water and denture cleansers. The binding levels of C. albicans were significantly decreased in the following order: COE-SOFT$^{TM}$, GC RELINE$^{TM}$, SOFRELINER TOUGH$^{(R)}$, and acrylic resin. The immersion in Cleadent$^{(R)}$ seemed to decrease C. albicans binding level on GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$. CONCLUSION. Based on the C. albicans binding levels results, it is not recommended to immerse COE-SOFT$^{TM}$ in denture cleansers, and GC RELINE$^{TM}$ and SOFRELINER TOUGH$^{(R)}$ should be immersed in Cleadent$^{(R)}$.

의치 접착제가 총의치의 유지력에 미치는 영향에 관한 연구 (The effect of denture adhesives on the retention of complete denture)

  • 윤유미;최유성;이준석
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.87-93
    • /
    • 2010
  • 연구목적: 의치 접착제는 구강 내 의치 장착 시 유지에 도움을 주는 위해 사용되는 재료로써 의치상과 점막 사이에 계면력을 증가시켜 유지를 향상시킨다. 이에 본 실험은 의치 접착제의 유지력을 생체 외 실험으로 비교, 평가하는 것으로 실리콘 무치악 모형과 레진 의치상 간의 인장력을 측정하여 의치 접착제의 유지력을 비교, 평가하고 탈락력이 가해진 방향에 따른 유의성을 알아보고자 하였다. 연구 재료 및 방법: 두가지 의치 접착제로 POLIDENT$^{(R)}$와 COREGA$^{(R)}$를 사용하여 레진 의치상에 적용시키고, 실리콘 모형에 적합시킨 후 인스트론으로 인장력을 측정하였다. 인공타액으로 접착제의 농도를 점점 희석시켜 반복 측정하였고, 수직력, 측방력, 전후방력을 각각 측정하여 비교하였다. 결과:1. 인공타액만을 사용한 대조군과 비교시 의치 접착제를 사용한 군에서 유의성 있는 유지력 증가를 보였다 (P<.05). 2. 희석횟수에 따른 비교 시 두 접착제 군에서 모두 1회 희석 시에는 희석시키지 않은 군과 유의한 차이를 보이지 않았으나 2회, 3회, 4회 희석시킨 군과는 유의한 차이를 보였다 (P<.05). 3. 탈락 방향에 따른 비교 시 수직 방향의 탈락력이 가장 컸으며 전후방력, 측방력의 순으로 유의성 있는 차이를 보였다 (P<.05). 4. 두 접착제 간의 접착력은 유의성 있는 차이를 보이지 않았다. 결론: 이상의 결과에서 접착제의 사용은 유지력 증가에 유용한 것으로 나타났고, 특히 수직적으로 가해지는 힘에 저항력이 큰 것으로 나타났다.

수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구 (Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth)

  • 최유성;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.129-146
    • /
    • 2008
  • 본 연구에서는 다양한 치과 수복재료에 대합되는 의치용 레진치의 마모저항성을 알아보기 위해 통상의 아크릴 릭 레진치인 $Trubyte^{(R)}$ $Biotone^{(R)}$ (Dentsply, U.S.A.)과 고강도 레진치인 Endura $Posterio^{(R)}$ (Shofu, Japan), Physio $Duracross^{(R)}$ (Nissin, Japan)를 수복재료인 금합금, 도재, 충전용 레진에 대합시켜 마모저항성을 비교 분석하였다. 또한 앞의 세 종류의 레진 인공치와 5종류의 의치세정제인 유한락스, 폴리덴트, 싸이덱스, 헥사메딘, 증류수를 사용하여 의치세정제 및 소독제가 경도에 미치는 영향을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 대합되는 수복재료로 충전용 레진, 도재를 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이감소가 컸으며 세 재료간의 유의한 차이를 보였다 (p<0.05). 2. 대합되는 수복재료로 금합금을 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이 감소가 컸으며, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$ 이 다른 두 종류의 인공치보다 유의성 있게 높은 교두정 높이 감소를 보였다 (p<0.05). 3. 대합되는 수복재료로 충전용 레진, 금합금, 도재를 사용한 경우 모두 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 무게 감소가 컸으며, 세 재료간의 유의한 차이를 보였다 (p<0.05). 4. 의치세정제에 따른 경도 감소는 실험 전과 후의 측정치를 비교했을 때 모든 레진 인공치에서 유의성 있는 차이 를 나타내었다 (p<0.05). 5. 유한락스, 싸이덱스, 헥사메딘에 담구었던 레진 인공치에 의한 경도감소는 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 높은 감소를 보였고, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$이 다른 두 종류의 인공치보다 유의성 있게 높은 경도 감소를 보였다 (p<0.05). 이상의 실험 결과 마모저항성 실험에서는 최근에 개발된 Physio $Duracross^{(R)}$가 다른 두 종류의 레진 인공치에 비해 세 종류의 대합되는 수복재료 모두에서 높은 마모저항성을 보였고 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 높은 마모저항성을 보였다. 경도 실험에서는 Physio $Duracross^{(R)}$와 Endura $Posterio^{(R)}$$Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 낮은 경도감소를 보였고 (p<0.05), 폴리덴트, 증류수에서는 유의한 차이를 보이지 않았다. 따라서, Physio $Duracross^{(R)}$가 세 종류의 레진 인공치에 비해 우수한 마모저항성을 보인다고 볼 수 있고, Endura $Posterio^{(R)}$와 함께 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해서 우수한 경도를 보인다고 볼 수 있지만, 단편적인 실험 결과이므로, 아직은 신중하게 고려되어야 하고, 더 많은 연구가 필요하다고 사료된다.