배전용 변압기 절연유의 특성 비교 평가 (The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer)

  • 이병성;박영근;김동명;김필환;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용 (The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers)

  • 이병성;송일근;이재봉;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

퍼지 모델을 이용한 주상 변압기 수용가 특성 구분 (Classification Customer characteristic of Pole-Transformer using Fuzzy Model)

  • 김기현;임진순;윤상윤;오정환;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.276-278
    • /
    • 1999
  • In this paper, we analyze customers' working electric energy (kWh) which is served pole-transformer in order to reduce peak load current error which is generated in application load correlation equation. The characteristic of electric load which customers are using is classified by customer's working electric energy (kWh) and ratio of cooling equipment possession. For the input data of fuzzy model, we used to kWh on April which represents basic load and kWh which is increased from April to August. The April kWh is used to classify into large, medium, small customer. Also, the increased kWh is used to know information of cooling equipment possession. For the output value of fuzzy model, we can determined peak load current limit in application load correlation equation.

  • PDF

주상변압기의 열화에 따른 절연유내 금속성분 증가와 절연특성과의 관계 (The relation between increment of metallic content arid dielectric characteristics in insulation oil according to degradation of Pole transformer)

  • 이동준;김영찬;정용기;남궁미옥;윤영자;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1746-1748
    • /
    • 1998
  • In this paper, the relation between the increment of metallic content such as copper(Cu) and iron(Fe) according to degradation of pole-transformer oil and change of electrical characteristics according to increment of metallic content was studied. As the result, electrical characteristics was decrease according to increment of metallic content, especially copper content, and the trend of T.C.G(Total Carbonic Gas) agreed with the trend of copper content.

  • PDF

전기집진기술의 현황과 장래전망(I)

  • 고명삼;이달우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.24-33
    • /
    • 1997
  • 본 논문에서는 주상변압기 절연유의 가속열화반응을 수행하였다. 유중가스를 air bubbling법으로 추출하여 가스크로마토그라프로 성분을 분석하였으며 가스농도는 각 가스의 추출율을 감안하여 보정하였다. 절연재료의 열화는 열분해반응과 산화반응에 의하여 진행되었으며 두종류의 반응은 모두 0차반응의 특성을 보였고 탄화수소류, $CO+CO_2$ 및 수소가스의 생성속도식을 얻었다. 유중가스 분석과 UV-Visible 분광광도법에 의하여 변압기내의 철심과 동코일이 열화과정에서 촉매역활을 함에 확인하였다.

  • PDF

주상 변압기의 절연유 유전정접 활선 측정 기법 (The On-Line Measuring of Dissipation Factor on pole Transformer)

  • 이수길;김재철;윤용한;이보호;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.853-855
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on the operating transformer by using digital signal processing. After applying voltage to the electrodes which is installed In a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques. we can check the dissipation factor of insulating oil. To Improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구 (Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP)

  • 이보호;김재철;윤용한;임성정;김언석;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

열 열화에 따른 변압기 절연물의 절연특성 분석 (Analysis of Insulation Characteristics for Transformer Insulating Materials According to Thermal Degradation)

  • 이민구;심재명;임경범;이대동
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1688-1693
    • /
    • 2016
  • In this study shall investigate the influence upon the electrical property of transformer oil due to the heat among accelerated heat degradation experiment for a constant hour in the typical insulation oils of mineral base oil, silicon base oil and vegetable oil. In addition, the electric insulation performance of insulation materials in transformer shall be evaluated through the electric property analysis according to the heat degradation of epoxy insulation material, which has been used for electric facilities such as a molded transformer.

콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구 (A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit)

  • 이광직
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

주상변압기용 절연지의 가속화 후 전기적 특성 (Electrical Characteristics of Insulating Paper for Pole Transformers after Accelerated Ageing)

  • 송일근;정종욱;이병성;한용희;김찬영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1591-1593
    • /
    • 2001
  • In this paper, the electrical characteristics of Insulating paper, for pole transformers, subjected to accelerated ageing were observed and the results were compared with those of virgin insulating paper. For the experiment, insulating materials for pole transformers were enclosed together in an oil bath and thermally aged under the real pole transformer operating conditions. After the accelerated ageing of the insulating materials, the dielectrics were measured and compared with the results of the virgin ones.

  • PDF