• 제목/요약/키워드: Polarization Condition

검색결과 291건 처리시간 0.032초

전력 케이블용 저밀도 폴리에틸렌의 냉각 조건에 따른 기계적 및 유전손실에 관한 연구 (A study on the Dynamic Mechanical and Dielectric Loss according to Quenched Condition in Low Density Polyethylene fer Power Cable)

  • 김재환;권병휘;박재준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.27-37
    • /
    • 1992
  • We studied the dielectric and dynamic mechanical losses according to the quenching condition in low density polyethylene being used to power cables. According to severe quenching condition, characteristics of the temperature in internal friction los peak have decreased the magnitude of loss peak as amorphous region lengthen. From now on, the frequency dependent characteristics of dielectric loss have investigated at room temperature, and the dielectric loss peak due to interface polarization, between crystal and amorphous region, occurs about 30[Hz], and that, the peak due to orientation polarization in correspondence to the loss peak in internal friction has observed at about 3 [MHz]. As quenching velocity increased, the effect on quenching condition about the dielectric loss has decreased the magnitude of the loss peak. Thus, estimation has been carried out on the activation energies nd the degree of crystallinity by means of X-ray diffraction are obtained as follows: room quenching : 26.4 [kal/mole] and 54.73 [%], ice quenching : 25.6 [kcal/mole] and 48.47 [%], liquid nitrogen quenching specimens : 22.56 [kcal/mole] and 40.95 [%].

  • PDF

EBG 표면 위의 단일 방향 복사 등각 안테나의 성능 해석 (Performance Analysis of the Uni-Directional Radiation Equiangular Antenna over EBG Surface)

  • 윤성현;김재관
    • 한국통신학회논문지
    • /
    • 제40권8호
    • /
    • pp.1622-1630
    • /
    • 2015
  • 본 연구에서는 원형편파를 양방향으로 복사하는 등각 스파이럴 안테나에 EBG(electromagnetic bandgap) 반사판을 사용하여 단일 방향으로 복사가 발생하게 하였다. EBG 반사판에서 스파이럴 암 까지의 높이가 가장 낮은 동작 주파수의 0.07 파장 높이로 한 경우, 원형편파의 축비가 손상되는 것이 발생하였다. 본 논문에서는, +z 방향에서의 동일 편파인 우선 원형 편파를 발생시키는 $E_{\theta},E_{\phi}$의 크기와 시간 위상차를 해석하여, 전 주파수 영역에서 축비를 개선하는 조건을 제시하였다. 그 결과, 3 ~ 10[dB] 주파수 범위에서 축비는 3[dB] 이하이고, 이득은 자유공간에서의 양방향 복사와 비교해서 약 3[dB] 정도 개선되었고, $S_{11}$은 전 주파수 영역에서 -10[dB]이하를 얻었다.

Al-4.5%Mg-0.6%Mn 알루미늄 합금의 정전위 시간 변수에 따른 손상거동 평가 (Evaluation on Damage Behavior of Al-4.5%Mg-0.6%Mn Al Alloy with Potentiostatic Experiment Time)

  • 김성종;우용빈;한민수;장석기
    • 해양환경안전학회지
    • /
    • 제18권6호
    • /
    • pp.569-576
    • /
    • 2012
  • 일반적으로 중성용액 하에서 알루미늄 합금은 부동태피막($Al_2O_3$$Al_2O_3{\cdot}3H_2O$)을 형성한다. 그러나, 해수 환경에서 염소이온이 표면에 생성된 부동태 피막을 파괴하여 부식이 발생하게 된다. 본 연구에서는 해수환경 하에서 부식 문제점을 해결하기 위해 Al-4.5%Mg-0.6%Mn 알루미늄 합금에 대하여 정전위 방식 기술을 적용하였다. 분극실험결과, 개로전위보다 귀한 전위에서는 활성 용해 반응이 나타났으며 개로전위 보다 비한 전위에서는 용존산소 환원에 의한 농도 분극과 활성화 분극이 관찰되었다. 정전위 실험결과, 농도 분극에서 활성화 분극으로 전환되는 전위부터 적용 시간이 증가할수록 전착물이 많이 생성되었으며, 부분적으로 전착물과 모재의 계면사이에서 틈부식이 관찰되었다. 전체적으로 정전위 양극분극실험시, 활성용해반응이 발생하여 정전위 방식 기술을 적용하기 어려운 반면, 정전위 음극분극 실험시 방식 전위인 농도분극 범위내에서 적용 시간을 고려하여 최적 방식 조건을 -1.1 V~-0.75 V로 규명하였다.

염화물 환경에 있는 에폭시도막철근의 부식 평가 연구 (Corrosion Evaluation of Epoxy-coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests)

  • 박영수;최경민;정시영;김병국;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.254-257
    • /
    • 2006
  • Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using linear polarization technique show that the current density of specimen with conventional steel becomes $0.715\;{\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below $0.1\;{\mu}A/cm^2$ and the bars appears to be in passive condition. The corrosion protection performance provided by calcium nitrite is better than that of specimens with the other two inhibitors.

  • PDF

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

Solid-state NMR Study on Membrane Protein Structure in Biological Condition

  • Kang, Su-Jin;Lee, Bong-Jin
    • 한국자기공명학회논문지
    • /
    • 제16권2호
    • /
    • pp.103-110
    • /
    • 2012
  • Membrane proteins play a essential role in the biological systems and it is not easy to handle a membrane protein for its structural study. Solid-state NMR (ssNMR) can be a good tool to investigate the structures and dynamics of membrane proteins. In ssNMR, Magic Angle Spinning (MAS) and Cross Polarization (CP) can be utilized to reduce the line-broadening, leading to high resolution and sensitivity in the spectrum. ssNMR, if combined with other spectroscopic methods, can provide us a enough knowledge on structures and dynamics of membrane proteins in biological condition.

Effect of pH and Concentration on Electrochemical Corrosion Behavior of Aluminum Al-7075 T6 Alloy in NaCl Aqueous Environment

  • Raza, Syed Abbas;Karim, Muhammad Ramzan Abdul;Shehbaz, Tauheed;Taimoor, Aqeel Ahmad;Ali, Rashid;Khan, Muhammad Imran
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.213-226
    • /
    • 2022
  • In the present study, the corrosion behavior of aluminum Al-7075 tempered (T-6 condition) alloy was evaluated by immersion testing and electrochemical testing in 1.75% and 3.5% NaCl environment at acidic, neutral and basic pH. The data obtained by both immersion tests and electrochemical corrosion tests (potentiodynamic polarization and electrochemical impedance spectroscopy tests) present that the corrosion rate of the alloy specimens is minimum for the pH=7 condition of the solution due to the formation of dense and well adherent thin protective oxide layer. Whereas the solutions with acidic and alkaline pH cause shift in the corrosion behavior of aluminum alloy to more active domains aggravated by the constant flux of acidic and alkaline ions (Cl- and OH-) in the media which anodically dissolve the Al matrix in comparison to precipitated intermetallic phases (cathodic in nature) formed due to T6 treatment. Consequently, the pitting behavior of the alloy, as observed by cyclic polarization tests, shifts to more active regions when pH of the solutions changes from neutral to alkaline environment due to localized dissolution of the matrix in alkaline environment that ingress by diffusion through the pores in the oxide film. Microscopic analysis also strengthens the results obtained by immersion corrosion testing and electrochemical corrosion testing as the study examines the corrosion behavior of this alloy under a systematic evaluation in marine environment.

Process and Characteristics of High Power Catalyst Electrode for PEM Fuel Cell

  • Chang H.;Lim C.;Kim J.
    • 전기화학회지
    • /
    • 제2권3호
    • /
    • pp.171-175
    • /
    • 1999
  • Novel process for high power catalyst electrode for PEM fuel cell has been developed. MEA having this catalyst electrode showed $0.5W/cm^2\;with\;0.2mg/cm^2$ of Pt loading at aunospheric humid hydrogen and oxygen condition. In this process, platinized carbon and plain carbon powders were coated with ionomer (Nafion) and hydrophobic polymer (PTFE), respectively and it could maximize two roles of catalyst electrode, l.e., reaction and gas supplying component. Those polarization characteristics proved the improved performance by reducing potential drop especially in the concentration polarization region.

칼코게나이드 박막을 이용한 편광 홀로그래픽의 회절효율 측정 (The Measurement on Diffraction Efficiency in Polarization Holography using Amorphous Chalcogenide Thin Films)

  • 장선주;여철호;이현용;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.87-90
    • /
    • 1999
  • The dependence of diffraction efficiency as a funct~on of film thickness and incident angle has been investigated in amorphous chalcogenide thin films, which act as a polarization holographic materials. Especially a-(Se, S) based films exhibit a number of photoinduced phenomena not observed in other types of amorphous thin films. Holographic gratings in amorphous As-Ge-Se-S thin films have been formed using the mutual perpendicular polarized(linearly) He-Ne laser light. We could obtain the optimum condition to get high diffraction efficiency.

  • PDF

다양한 코팅 방법에 따른 전조한 강 볼트의 내부식성 (1) (Corrosion Resistance of the Roll Formed Steel Bolts with the Various Types of Coating Methods (1))

  • 사바르;보보무로드;손요헌;김인수
    • 소성∙가공
    • /
    • 제28권2호
    • /
    • pp.71-76
    • /
    • 2019
  • Corrosion resistance is one of the essential properties required in steel bolts. The various types of coatings are used to improve the corrosion resistance of steel bolts. But, roll formed, subsequently Zn alloy electrodeposited and top coated steel bolt easily takes place the white storage stain or white rust under high humidity condition. To investigate the corrosion resistance of roll formed and subsequently the various types of coated steel bolts, their polarization curves were measured by potentio-dynamic tester in this study. Based on the measured polarization curves, the more times of chromate and top coating on roll formed steel bolt, the higher corrosion resistance was shown. The roll formed steel bolt, which was Zn-Ni electro-deposited, two times chromated, one time inorganic top coated, one time organic top coated and annealed, showed the best corrosion resistance.