• 제목/요약/키워드: Point machine

검색결과 1,138건 처리시간 0.026초

Fracture Resistance and Stress Distribution of All Ceramic Crowns with Two Types of Finish Line on Maxillary First Premolar (상악 제1소구치에서 전부도재관의 finish line 형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Lee, Sang-Kwon;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제19권3호
    • /
    • pp.219-237
    • /
    • 2003
  • he purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown, and 0.5mm width chamfer finish lines on the maxillary first premolar. 30 sound maxillary first premolars were selected and then storaged in 5% NaOCl and saline. 15 teeth were performed preparation for each group(1.0mm rounded shoulder, 0.5mm chamfer). After 30 stone dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the natural teeth. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co., Germany)was used to measure the fracture strength, with stress loading on the occlusal surface between buccal and lingual cusp. And also, three-dimensional finite element model was used to measure the stress distribution with two types of the finish lines(1.0mm rounded shoulder, 0.5mm chamfer) and two loading conditions(both buccal and lingual cusp inclination, lingual cusp inclination only). The result of the this study were as follows. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(842N) showed higher value than that of the chamfer(590N) (p<0.05). In the three dimensional finite element analysis of all ceramic crown, metal die and natural teeth model did not show any differences in stress distribution between finish lines. Generally, when force was loaded on the occlusal inclination of buccal and lingual cusp, the stress was concentrated on the loading point and the central groove of occlusal surface. When force was loaded only on the occlusal inclination of lingual cusp, the stress was concentrated on the lingual finish line and loading point.

Haptic recognition of the palm using ultrasound radiation force and its application (초음파 방사힘을 이용한 손바닥의 촉각 인식과 응용)

  • Kim, Sun Ae;Kim, Tae Yang;Lee, Yeol Eum;Lee, Soo Yeon;Jeong, Mok Kun;Kwon, Sung Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제38권4호
    • /
    • pp.467-475
    • /
    • 2019
  • A high-intensity ultrasound wave generates acoustic streaming and acoustic radiation forces when propagating through a medium. An acoustic radiation force generated in a three-dimensional space can produce a solid tactile sensation, delivering spatial information directly to the human skin. We placed 154 ultrasound transmit elements with a frequency of 40 kHz on a concave circular dish, and generated an acoustic radiation force at the focal point by transmitting the ultrasound wave. To feel the tactile sensation better, the transmit elements were excited by sine waves whose amplitude was modulated by a 60 Hz square wave. As an application of ultrasonic tactile sensing, a region where tactile sense is formed in the air is used as an indicator for the position of the hand. We confirmed the utility of ultrasonic tactile feedback by implementing a system that provides the number of fingers to a machine by receiving the shape of the hand at the focal point where the tactile sense is detected.

Optimization Algorithm of Gantry Route Problem for Odd-type Surface Mount Device (이형 부품 표면실장기에 대한 겐트리 경로 문제의 최적 알고리즘)

  • Jeong, Jaewook;Tae, Hyunchul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • 제43권4호
    • /
    • pp.67-75
    • /
    • 2020
  • This paper proposes a methodology for gantry route optimization in order to maximize the productivity of a odd-type surface mount device (SMD). A odd-type SMD is a machine that uses a gantry to mount electronic components on the placement point of a printed circuit board (PCB). The gantry needs a nozzle to move its electronic components. There is a suitability between the nozzle and the electronic component, and the mounting speed varies depending on the suitability. When it is difficult for the nozzle to adsorb electronic components, nozzle exchange is performed, and nozzle exchange takes a certain amount of time. The gantry route optimization problem is divided into the mounting order on PCB and the allocation of nozzles and electronic components to the gantry. Nozzle and electronic component allocation minimized the time incurred by nozzle exchange and nozzle-to-electronic component compatibility by using an mixed integer programming method. Sequence of mounting points on PCB minimizes travel time by using the branch-and-price method. Experimental data was made by randomly picking the location of the mounting point on a PCB of 800mm in width and 800mm in length. The number of mounting points is divided into 25, 50, 75, and 100, and experiments are conducted according to the number of types of electronic components, number of nozzle types, and suitability between nozzles and electronic components, respectively. Because the experimental data are random, the calculation time is not constant, but it is confirmed that the gantry route is found within a reasonable time.

KOCED performance evaluation in the wide field of wireless sensor network (무선센서망 내 KOCED 라우팅 프로토콜 광역분야 성능평가)

  • Kim, TaeHyeon;Park, Sea Young;Yun, Dai Yeol;Lee, Jong-Yong;Jung, Kye-Dong
    • The Journal of the Convergence on Culture Technology
    • /
    • 제8권2호
    • /
    • pp.379-384
    • /
    • 2022
  • In a wireless sensor network, a large number of sensor nodes are deployed in an environment where direct access is difficult. It is difficult to supply power, such as replacing the battery or recharging it. It is very important to use the energy with the sensor node. Therefore, an important consideration to increase the lifetime of the network is to minimize the energy consumption of each sensor node. If the energy of the wireless sensor node is exhausted and discharged, it cannot function as a sensor node. Therefore, it is a method proposed in various protocols to minimize the energy consumption of nodes and maintain the network for a long time. We consider the center point and residual energy of the cluster, and the plot point and K-means (WSN suggests optimal clustering). We want to evaluate the performance of the KOCED protocol. We compare protocols to which the K-means algorithm, one of the latest machine learning methods, is applied, and present performance evaluation factors.

Canopy Microclimate of Water-Seeding Rice during Internode Elongation Period (담수직파 벼의 신장기 군락내 미기후 특성)

  • Yun, Jin-Il;Shin, Jin-Chul;Yun, Yong-Dae;Park, Eun-Woo;Cho, Seong-In;Hwang, Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • 제42권4호
    • /
    • pp.473-482
    • /
    • 1997
  • Temperature, humidity and wetness duration were monitored for fully developed paddy rice canopies with 3 different structures induced by the seeding method(puddled-soil drill seeding, DS ; hand broadcasting, HB ; machine broadcasting, MB). Within-canopy air temperature averaged over "clear sky" hours during the study period(maximum tillering through heading) was lower than the screen temperature at a nearby standard weather station, especially in the night. The same trend was true for "overcast sky" hours except the diurnal distinction. Vapor pressure within the canopy was high during the daytime and low in the night, making the daytime deviation from outside the canopy more significant on clear days. Under the overcast sky, the canopy maintained a steady 5 to 10% higher vapor pressure than the outside regardless of day or night. Daily maximum temperature was observed to be higher within the canopies with more leaf mass, making MB the highest, HB the lowest, and DS in between. Relative humidity was over 90% in the night and dropped to 70% in the mid-afternoon, but vapor pressure within the canopy was highest at around 13:00 LST. Dew point depression was lowest and, combined with the temperature, the relative humidity was highest in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.

  • PDF

Evaluation of Flexural Strength of 3D Printing Resin According to Post-Curing Equipment and Time (후경화기와 경화시간에 따른 3D 프린팅 레진의 굴곡강도 평가)

  • Hae-Bom Kim;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제26권4_2호
    • /
    • pp.629-637
    • /
    • 2023
  • This study aimed to evaluate the effect of post-curing equipment and time on the flexural strength of 3D printing resins produced by a liquid crystal display(LCD) printer. The three 3D printing resins(DENTCA Denture Teeth, DT; C&B 5.0 hybrid, CH; C&B Permanent A2, CP) were divided into four groups according to post-curing time(10 min and 30 min) and equipment with or without vacuum treatment. For the three-point flexural strength test and biaxial strength test were prepared by method according to ISO 10477, ISO 6872, respectively. Flexural strength was measured with universal testing machine. Comparison between post-curing time of each post-curing equipment was analyzed by independent sample t-test and Mann-Whitney U test(α=.05), and comparison between groups according to each 3D printing resin was performed by Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(α=.05). The flexural strength of the resin post-curing under vacuum was higher than that of the resin post-curing in air. In the comparison according to the post-curing time, in the case of the post-curing equipment without vacuum, the 30 minute curing time showed significantly higher flexural strength than the 10 minute curing time, except for the biaxial flexural strength of CH(P<.05). In the post-curing equipment with vacuum, the three-point flexural strength of all 3D printing resins(DT, CH, and CP) showed a higher value at 30 minute curing time than at 10 minute curing time.

Autonomous exploration for radioactive sources localization based on radiation field reconstruction

  • Xulin Hu;Junling Wang;Jianwen Huo;Ying Zhou;Yunlei Guo;Li Hu
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1153-1164
    • /
    • 2024
  • In recent years, unmanned ground vehicles (UGVs) have been used to search for lost or stolen radioactive sources to avoid radiation exposure for operators. To achieve autonomous localization of radioactive sources, the UGVs must have the ability to automatically determine the next radiation measurement location instead of following a predefined path. Also, the radiation field of radioactive sources has to be reconstructed or inverted utilizing discrete measurements to obtain the radiation intensity distribution in the area of interest. In this study, we propose an effective source localization framework and method, in which UGVs are able to autonomously explore in the radiation area to determine the location of radioactive sources through an iterative process: path planning, radiation field reconstruction and estimation of source location. In the search process, the next radiation measurement point of the UGVs is fully predicted by the design path planning algorithm. After obtaining the measurement points and their radiation measurements, the radiation field of radioactive sources is reconstructed by the Gaussian process regression (GPR) model based on machine learning method. Based on the reconstructed radiation field, the locations of radioactive sources can be determined by the peak analysis method. The proposed method is verified through extensive simulation experiments, and the real source localization experiment on a Cs-137 point source shows that the proposed method can accurately locate the radioactive source with an error of approximately 0.30 m. The experimental results reveal the important practicality of our proposed method for source autonomous localization tasks.

The Perceived Discomfort of Plateletpheresis Donors (성분 헌혈자가 혈소판 반출시 지각하는 불편감)

  • 김상돌
    • Journal of Korean Academy of Nursing
    • /
    • 제27권3호
    • /
    • pp.577-587
    • /
    • 1997
  • Purpose : To collect and interpret basic data involving the discomfort level of platelet donors and to see which nursing interventions would help make plateletpheresis more comfortable. Methods : Using "the Platelet Donor's Discomfort Scale" developed by the researcher herself and reviewed by an expert panel, the severity of discomfort as well as factors contributing to the development of this discomfort were analyzed. This scale contained 59 items and each item was scored by the 4-point Likert manner. Between March 1, 1996 and May 31, 1996, 500 platelet donors(16 years of age and older) were enrolled in this study. The Statistical methods used were factor analysis, t-test, and ANOVA. The results were as follows : 1. The mean of the platelet donor's discomfort scale was 130, range 69-207, possible score ranging from 59-236. 2. The platelet donor's discomfort scale had psychological, environmental, physical, and time-related factors. The time- related factor was the highest positive correlation with the development of the discomfort. 3. In looking at the psychological and environmental factors of the discomfort scores, the 16-20 age group had significantly higher ratings than those of the 26-30 age group. The students' group had higher scores than the soldier's group, and those who used the V-50, MCS -3P, or the PCS Plus machines had higher scores than those who used the COBE Spectra machine(P<.05, respectively), 4. In relation to the physical factor of the discomfort score, the youngest group felt significantly more discomfort, the student's group had a higher score than the soldier's group, and those who used the V-50, MCS-3P, or or the PCS Plus machines had higher scores than those who used the COBE Spectra machine(P<.05, respectively). 5. The time related factor of the discomfort score had the highest scores in every variable, however, statistically significant differences were not found between any of the variables(P>.05). Conclusion : Based on the above results, it can be oserved that the time-related factor was the most important factor influencing discomfort. The age and job of the donor, as well as the type of machine used, were significant variables in predicting the level of discomfort, regardless of psychological, environmental, and physical factors. This data could be used to determine nursing interventions that would relieve some of the discomfort of patients, as well as donors, undergoing plateletpheresis. Furthermore, consideration of the donor's time, introduction of a platelet donor pool system, publicity and education about platelet donation are required.

  • PDF

An On-chip ESD Protection Method for Preventing Current Crowding on a Guard-ring Structure (가드링 구조에서 전류 과밀 현상 억제를 위한 온-칩 정전기 보호 방법)

  • Song, Jong-Kyu;Jang, Chang-Soo;Jung, Won-Young;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제46권12호
    • /
    • pp.105-112
    • /
    • 2009
  • In this paper, we investigated abnormal ESD failure on guard-rings in the smart power IC fabricated with $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology. Initially, ESD failure occurred below 200 V in the Machine Model (MM) test due to current crowding in the parasitic diode associated with the guard-rings which are generally adopted to prevent latch-up in high voltage devices. Optical Beam Induced Resistance Charge (OBIRCH) and Scanning Electronic Microscope (SEM) were used to find the failure spot and 3-D TCAD was used to verify cause of failure. According to the simulation results, excessive current flows at the comer of the guard-ring isolated by Local Oxidation of Silicon (LOCOS) in the ESD event. Eventually, the ESD failure occurs at that comer of the guard-ring. The modified comer design of the guard-ring is proposed to resolve such ESD failure. The test chips designed by the proposed modification passed MM test over 200 V. Analyzing the test chips statistically, ESD immunity was increased over 20 % in MM mode test. In order to avoid such ESD failure, the automatic method to check the weak point in the guard-ring is also proposed by modifying the Design Rule Check (DRC) used in BCD technology. This DRC was used to check other similar products and 24 errors were found. After correcting the errors, the measured ESD level fulfilled the general industry specification such as HBM 2000 V and MM 200V.

Machine-Learning Based Biomedical Term Recognition (기계학습에 기반한 생의학분야 전문용어의 자동인식)

  • Oh Jong-Hoon;Choi Key-Sun
    • Journal of KIISE:Software and Applications
    • /
    • 제33권8호
    • /
    • pp.718-729
    • /
    • 2006
  • There has been increasing interest in automatic term recognition (ATR), which recognizes technical terms for given domain specific texts. ATR is composed of 'term extraction', which extracts candidates of technical terms and 'term selection' which decides whether terms in a term list derived from 'term extraction' are technical terms or not. 'term selection' is a process to rank a term list depending on features of technical term and to find the boundary between technical term and general term. The previous works just use statistical features of terms for 'term selection'. However, there are limitations on effectively selecting technical terms among a term list using the statistical feature. The objective of this paper is to find effective features for 'term selection' by considering various aspects of technical terms. In order to solve the ranking problem, we derive various features of technical terms and combine the features using machine-learning algorithms. For solving the boundary finding problem, we define it as a binary classification problem which classifies a term in a term list into technical term and general term. Experiments show that our method records 78-86% precision and 87%-90% recall in boundary finding, and 89%-92% 11-point precision in ranking. Moreover, our method shows higher performance than the previous work's about 26% in maximum.