• Title/Summary/Keyword: Plastic Stability

Search Result 604, Processing Time 0.028 seconds

Obtaining Maximal Stability with a Septal Extension Technique in East Asian Rhinoplasty

  • Jeong, Jae Yong
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.19-28
    • /
    • 2014
  • Recently, in Korea, the septal extension graft from the septum or rib has become a common method of correcting a small or short nose. The success rate of this method has led to the blind faith that it provides superior tip projection and definition, and to the failure to notice its weaknesses. Even if there is a sufficient amount of cartilage, improper separation or fixation might waste the cartilage, resulting in an inefficient operation. Appropriate resection and effective fixation are essential factors for economical rhinoplasty. The septal extension graft is a remarkable procedure since it can control the nasal tip bidirectionally and three dimensionally. Nevertheless, it has a serious drawback since resection is responsible for septal weakness. Safe resection and firm reconstruction of the framework should be carried out. Operating on the basis of the principle of "safe harvest" and rebuilding the structures is important. Further, it is important to learn several techniques to manage septal weakness, insufficient cartilage quantity, and failure of the rigid frame during the surgery.

A Study on the Improvement of Double Injection-molding Keypad Process (이중 사출 키패드 성형 공정 개선에 관한 연구)

  • Hong, Min-Sung;Lee, Ji-Hoon;Shin, Soo-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.659-665
    • /
    • 2011
  • Recently, the plastic resin such as PC, ABS are widely used in IT market. Especially, in most cases the keypads mounted on the mobile phone are the dual-injection-plated type. Environmental regulation is based on the quality of injection-molded products and the minimum process steps are required to avoid the plating defects. Various parameters to produce the injection-molded plastic products make it difficult to obtain the desired stability. However, the past experience and the use of CAE analysis make it possible to predict the problems occurred in injection molding process. Especially, the problems of the weld lines such as runner balancing, bending, deformation and forming defects can be solved systematically and minimized by CAE analysis. Through this study, the non-uniform volumetric shrinkage and the difference in temperature distribution induce the deformation and the high value of stress causes the problems such as crack.

Dynamic Analysis of 3 Point Bend Specimens under High Loading Rates

  • Han, Moon-Sik;Cho, Jae-Ung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.2
    • /
    • pp.84-93
    • /
    • 2000
  • Computer simulations of the mechanical behavior of 3 point bend specimens with a quarter notch under impact load are performed. This validity is found to be identified by the experimental proof. The cases with various loading rates applied at the side of the specimen are considered. An elastoplastic von Mises material model is chosen. Gap opening displacement, reaction force, crack tip opening displacement and strain rate are also compared with rate dependent material(visco-plastic material). The stability during various dynamic load can be seen by using the simulation of this study. These differences of the cases with various loading rates are also investigated.

  • PDF

Transaxillary Endoscopic Breast Augmentation

  • Sim, Hyung-Bo
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.458-465
    • /
    • 2014
  • The axillary technique is the most popular approach to breast augmentation among Korean women. Transaxillary breast augmentation is now conducted with sharp electrocautery dissection under direct endoscopic vision throughout the entire process. The aims of this method are clear: both a bloodless pocket and a sharp non-traumatic dissection. Round textured or anatomical cohesive gel implants have been used to make predictable welldefined inframammary creases because textured surface implants demonstrated a better stability attributable to tissue adherence compared with smooth surface implants. The axillary endoscopic technique has greatly evolved, and now the surgical results are comparable to those with the inframammary approach. The author feels that this technique is an excellent choice for young patients with an indistinct or absent inframammary fold, who do not want a scar in the aesthetic unit of their chest.

Change of groundwater inflow by cutoff grouting thickness and permeability coefficient

  • Kim, Youngsang;Moon, Joon-Shik
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.165-170
    • /
    • 2020
  • The groundwater during tunnel excavation not only affects the stability of the tunnel and constructability but also causes the subsidence of the upper ground due to the lowering of groundwater. Generally, the cutoff grouting is applied as a countermeasure to reduce the groundwater inflow during tunnel excavation, and the cutoff grouting is often applied in the range of plastic zone around the tunnel. However, grouting in the plastic zone is only appropriate for ground reinforcement purposes, and guidelines for the application range of cutoff grouting and the targeted permeability coefficient of the grouting zone are required. In this study, the relationship between groundwater inflow into tunnel and application range of cutoff grouting and permeability coefficient is proposed and compared with numerical analysis results. It was found that grouting with tunnel radius thickness is appropriate to reduce the groundwater inflows effectively. More than 90% reduction in groundwater inflow can be achieved when the annular area of the tunnel radius thickness is grouted with a permeability reduction ratio of 1/50~1/200.

A Study on the Tissue Response and Bone Formation after Augmentation Using Proplast and Porous Polyethylene in Rabbit Mandible (Proplast와 Porous Polyethylene을 이용(利用)한 가토(家兎) 하악골(下顎骨) 증대술후(增大術後) 조직반응(組織反應) 및 골형성(骨形成)에 관(關)한 연구(硏究))

  • Kim, Geon-Jung;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.101-116
    • /
    • 1989
  • Proplast and Porous Polyethylene which have porous structures as low-modulus polymers have been recently used in maxillofacial plastic and reconstructive surgery. The purpose of this study was to compare the response of adajacent tissue, new bone formation and stability after augmentation by differen methods of subperiosteal graft using proplast and purous polythylene in rabbit mandible. The augmentation procedure was carried out by dividing into two groups, A and B. A group consisted of subperiosteal graft on the cortex, and the other B group was made up only graft following artificial decortication in the mandibular body of rabbit. The experimental animals were sacrificed on the 1st, 2nd, 4th and 8th week after grafting for macroscopic and light microscopic examination. The samples extracted at the 6th postgrafting week were also used for biometric testing and scanning electron microscopic examination. The results obtained from this study were as follows : 1. Macroscopically, infection of graft site, deformation and migration of graft material were not observed in all experimental groups. 2. B group showed more rapid and increased bone formation and the greater stability than A group, and tissue response was similar to each other. 3. In the tissue response, macrophages and cellular infiltrations were observed in Proplast group, but few in PHDPE group. 4. In bone formation of A group, Proplast group showed no bone formation until the 8th week, but PHDPE group showed small quantity of osteoid tissue from the 2nd week and appositional bone growth with new bone formation at the 8th week. 5. In bone formation of B group, both Proplast and PHDPE group showed bone formation, but PHDPE group showed more rapid and larger bone formation. 6. In pattern of bone formation, Proplast group mainly showed appositional bone growth pattern connected with graft site. On the other hand, PHDPE group showed mixed pattern of new bone formation in the pore connective tissue with appositional bone growth from graff site. 7. The maximum mean values of shear stress were serially $111.3gf/mm^{2}$ in PHDPE of B group, $84.8gf/mm^{2}$ in PHDPE of A group, $32.9gf/mm^{2}$ in Proplast B group, and $15.7gf/mm^{2}$ in Proplast of A group. From above results, It was suggested that the capacity of bone formation and stability between bone and graft material were dependent on the pore size and structure of graft material itself, the state of graft site and tissue response.

  • PDF

Experimental Study of Osseointegration and Stability of Intentionally Exposed Hydroxyapatite Coating Implants (의도적으로 연조직에 노출시킨 수산화인회석 코팅 임플란트의 골유착과 안정성에 대한 실험적 연구)

  • Jeong, Kyung-In;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Jo, Ji-Ho;Lim, Hyoung-Sup;Kim, Jeong-Sun;Lim, Sung-Chul;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the effect of exposure of hydroxyapatite coating on the amount of bone formation and stability in the dogs. Methods: In this study, hydroxyapatite coated implants (HAPTITE) was placed over the femur bone surface of four dogs about 1 mm. The experimental group was divided into 4 weeks group of 8 implants and 8 weeks group of 8 implants, and then they were sacrificed. The stability of implants was evaluated twice with Osstell$^{TM}$ mentor (Osstell AB, Goteborg, Sweden) at right after placement and sacrifice. The amount of bone formation was evaluated through histomorphometric examination. Results: The stability of implants was in normal range, and tended to increase as time goes by. Mean percentages of new bone formation rates were $90.5{\pm}6.6$ at uppermost 1 mm bone level adjacent to soft tissues (level 1) and $92.9{\pm}4.1$ at next 1 mm bone level (level 2) in 4 weeks group, $90.1{\pm}11.5$ at level 1 and $95.9{\pm}2.3$ at level 2 in 8 weeks group. Mean percentages of bone-implant contact rates were $85.1{\pm}10.8$ at level 1 and $88.1{\pm}13.8$ at level 2 in 4 weeks group, $88.5{\pm}14.4$ at level 1 and $95.3{\pm}3.1$ at level 2 in 8 weeks group. There was no statistically significant difference of new bone formation rate and bone-implant contact rate between uppermost 1 mm bone level adjacent to soft tissues and next 1 mm bone level. However, there was no significant difference in bone formation between 4 and 8 weeks groups. Conclusion: These results suggested that exposed hydroxyapatite coated implants to soft tissue showed favorable bone formation and implant stability.

Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant (수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교)

  • Lim, Hyoung-Sup;Kim, Su-Gwan;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

Skeletal Stability after Orthognathic Surgery in Severe Skeletal Class III Malocclusion Patients according to Changes in Anteroposterior Discrepancy and Occlusal Planes (골격성 III급 부정교합 환자에서 하악골의 이동량과 교합평면의 변화에 따른 술 후 안정성)

  • Lee, Jung-Han;Kim, Sung-Hee;Baek, Young-Jae;Ahn, Kyung-Yong;Hwang, Dae-Seok;Kim, Yong-Deok;Kim, Uk-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.404-412
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate postsurgical facial hard tissue stability after orthognathic surgery with/without posterior impaction in skeletal class III malocclusion patients, and to evaluate the horizontal relapse tendency, according to changes in anteroposterior discrepancy and occlusal planes. Methods: Ninety patients, who had undergone orthognathic surgery in Pusan National University Dental Hospital, were enrolled in this study. Three main groups were classified as follows: Thirty patients underwent mandibular setback bilateral sagittal split ramus osteotomy (BSSRO) only (BSSRO group, BG); another thirty patients underwent mandibular setback BSSRO and Le Fort I osteotomy with posterior impaction (posterior impaction group, PG); and another thirty patients underwent mandibular setback BSSRO and Le Fort I osteotomy without posterior impaction (non-posterior impaction group, NPG). Preoperative (T0), immediate postoperative (T1) and six-month follow-up period (T2) lateral cephalograms were taken, and various parameters were measured. The analyses were done by linear and angular measurements between T0-T1 and T1-T2, to evaluate postsurgical facial hard tissue stability. Results: Mean horizontal relapse rates were distributed from 11.81% to 19.08%, and there were significant postsurgical changes (0.52 mm~2.44 mm) at the B point in all 3 groups. But, there were no statistical differences on relapse rate among BG, PG and NPG patients. Conclusion: In this study, the postsurgical stabilities of BSSRO and Le Fort I osteotomy with/without posterior impaction in skeletal class III malocclusion patients were acceptable. There were no significant statistical differences in mandibular stability according to changes in anteroposterior discrepancy and occlusal planes.

Application of Slip-line Method to the Evaluation of Plastic Zone around a Circular Tunnel (원형터널 주변의 소성영역 평가를 위한 slip-line 해석법 활용)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.312-326
    • /
    • 2022
  • The generalized Hoek-Brown (GHB) criterion, which is recognized as one of the standard failure conditions for rock mass, is specialized for rock engineering applications and covers a wide range of rock mass conditions. Accordingly, many research efforts have been devoted to the incorporation of this criterion into the stability analysis of rock structures. In this study, the slip-line analysis method, which is a kind of elastoplastic analysis method, is combined with the GHB failure criterion to derive analytical equations that can easily calculate the plastic radius and stress distribution in the vicinity of the circular tunnel. In the process of derivation of related formulas, it is assumed that the behavior of rock mass after failure is perfectly plastic and the in-situ stress condition is hydrostatic. In the formulation, it is revealed that the plastic radius can be calculated analytically using the two respective tangential friction angles corresponding to the stress conditions at tunnel wall and elastic-plastic boundary. It is also shown that the plastic radius and stress distribution calculated using the derived analytical equations coincide with the results of Lee & Pietruszczak's numerical method published in 2008. In the latter part of this paper, the influence of the quality of the rock mass on the size of the plastic zone, the stress distribution, and the change of the tangential friction angle was investigated using the derived analytical equations.