• Title/Summary/Keyword: Plasma-atomic emission spectrometer

Search Result 62, Processing Time 0.029 seconds

A Real-Time Diagnostic Study of MgO Thin Film Deposition Process by ICP Magnetron Sputtering Method (MgO 증착을 위한 유도결합 플라즈마 마그네트론 스퍼터링에서 실시간 공정 진단)

  • Joo Junghoon
    • Journal of Surface Science and Engineering
    • /
    • v.38 no.2
    • /
    • pp.73-78
    • /
    • 2005
  • A real-time monitoring of ICP(inductively coupled plasma) assisted magnetron sputtering of MgO was carried out using a QMS(quadrupole mass spectrometer), an OES(optical emission spectrometer), and a digital oscilloscope with a high voltage probe and a current monitor. At the time of ICP ignition, the most distinct impurity was OH emission (308.9 nm) which was dissociated from water molecules. For reactive deposition oxygen was added to Ar and the OH emission intensity was reduced abruptly When the discharge voltage was regulated by a PID controller from 240V(metallic mode) to 120V(oxide mode), the emission intensity from Mg (285.2 nm) changed proportionally to the discharge voltage, but the intensity of Ar I(811.6 nm) was constant. At 100V of discharge voltage, Mg sputtering was almost stopped. Emissions from Ar I(420.1 nm) and Mg I were dropped down to 1/10, but Ar I(811.6 nm) didn't change. And the emission from atomic oxygen (O I, 777.3 nm) was increased to 10 times. These results are compatible with those from QMS study.

Characteristic Feature of Inductively Coupled Plasma Atomic Emission Spectrometer/Shielding System and Evaluation of Its Applicability to Analysis of Radioactive Materials (유도 결합 플라스마 원자방출분광기/차폐 시스템의 특성 및 방사성 물질 분석에 대한 적용성 평가)

  • Lee, Chang Heon;Suh, Moo Yul;Choi, Kae Chun;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.474-483
    • /
    • 2000
  • An inductively coupled plasma atomic emission spectrometer/shielding system was specially designed and built for the analysis of radioactive materials. Both of an inductively coupled plasma source and a sample transfer system to be contacted with radioactive materials was installed in a stainless steel glove box. In terms of analytical capability and radiation safety, characteristic feature of the system was investigated. Its applicability to the determination of fission products and corrosion products in the radioactive materials such as spent fuel dissolver solution and the primary coolant of nuclear power reactors was evaluated. In the concentration range $0.01-0.1mgL^{-1}$, the relative standard deviation was found to be less than 5%.

  • PDF

EMISSION LINE SPECTROSCOPY WITH THE 1.8M OPTICAL TELESCOPE (1.8m 망원경을 이용한 방출선 천체 연구)

  • HYUNG SIEK;ALLER LAWRENCE H.;KIM KANG-MIN
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.61-71
    • /
    • 2000
  • The emission line objects such as planetary nebulae, symbiotics, gaseous nebulae, HII regions, novae, supernovae, SNRs, nearby spiral galaxies, dIrr, dE, and nearby active galactic nuclei, would be goldmines for us to dig with the 1.8m bohyunsan optical (BOAO) telescope. We discussed the importance of strategically important diagnostic lines and atomic constant calculation for a study of Galactic and extragalactic emission objects. The scientific background on a spectrometer development history is briefly presented and spectroscopic research areas other than the emission objects are also summarized.

  • PDF

A Direct Reading Atomic Emission Spectrometer for Chemical Analysis in the Iron and Steels (직독식 원자방출분광기를 이용한 철강중의 성분원소 분석)

  • Kim, Yeong Man;Jeong, Chan Lee;Kim, Seon Tae;Choe, Beom Seok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.800-807
    • /
    • 1994
  • A method to determine the iron and steels employing a Direct Reading Atomic Emission Spectrometer was investigated. Matrix effect was removed by two correction methods which utilize linear and curvilinear functions. Although two methods gave different sets of matrix correction coefficients, the analytical results by the two methods gave the same results. The analytical results obtained by the present work were well agreed with those obtained by inductively coupled plasma spectrometry.

  • PDF

An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

  • Nam, Sang-Ho;Kim, Yu-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1967-1971
    • /
    • 2012
  • A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg.

Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) (토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교)

  • Lee, Hong-gil;Kim, Ji-in;Byun, Yoonjoo;Kim, Hyunkoo;Yoon, Jeong Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

Hazardous Substance Analysis of Disposable Diaper for Infant (유아용 일회용 기저귀의 유해성 평가)

  • 신정화;윤혜온;박미애;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.1
    • /
    • pp.165-171
    • /
    • 2004
  • The analytical method of toxic heavy metals in disposable diapers was developed. Disposable diapers obtained from Korea, Japan, America and German were determinated and quantified. Sample treatment (Total Digestion) was wet chemical acid digestion for extraction of nine hazardous inorganic elements (Sb, As, Pb, Cd, Cr, Co, Cu, Ni, Hg) in disposable diapers. Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) have been used for analyzing nine hazardous inorganic elements. The results were as follows : The concentration of extractable Sb which was treated for 3 hours with artificial urine and disposable diapers was higher than those of 6 hours and 24 hours. The concentration of extractable Cr was same as Sb. On the other hands, the behavior of Cu and Ni were different from Sb and Cr. Concentrations of extractable Cu and Ni increased as increasing the reaction time between artificial urine and disposable diapers.

Adsorption properties and metal growth aspects on the surface of activated carbon monolith electrochemically deposited with Ag

  • Oh, Won-Chun;Lim, Chang-Sung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.2
    • /
    • pp.37-46
    • /
    • 2004
  • The electrochemical adsorption of the Ag ions from aqueous solution on pelletized activated carbon monolith was investigated over wide range of operation time. The adsorption capacities of pelletized activated carbon monolith are associated with their internal porosity and are related properties such as surface area, pore size distribution. The chemical industry generates wastewater that contains toxic matters like heavy metals in small concentrations so that their economic recovery is not feasible. But, the method using activated carbon monolith can be used to withdrawal of heavy metals in waste water. After the electrochemical treatment, the quantitative properties in Ag ion solutions are also examined by pH concentration and studied elemental analysis by ICP-Atomic Emission Spectrometer and Energy Disperse X-ray (EDX) spectra. It is consider that the pH is very important factor at the reason of water pollutant with increasing acidity in industrial field. The result of quantitative analysis using Inductively Coupled Plasma-Atomic Emission Spectrometer of metal after electrochemical reaction in Ag ions solution depending on time are shown that the amount of Ag ions deposited was decreased with growth of Ag particles on the carbon surfaces as increasing electrochemically treated time. And, surface morphologies are investigated by scanning electron microscopy (SEM) to explain the changes in adsorption properties.

Development of an Axially Viewed Inductively Coupled Plasma for Atomic Emission Spectrometry and Comparison between the Detection Limits of Lead (원자방출 분광분석을 위한 수평형 유도결합 플라스마의 개발과 납 검출한계 비교)

  • Cho, Sung Il;Han, Myung Sub;Lee, Sang Hwa;Lee, Joung Hae;Woo, Jin Chun
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.6
    • /
    • pp.292-298
    • /
    • 1997
  • An ICP(Inductively Coupled Plasma) emission spectrometer was developed with an axially viewed ICP source incorporated by a 5-turned induction coil and a torch, outer quartz tube of which was 50 mm longer than that used in conventional ICP/AES(Inductively Coupled Plasma Atomic Emission Spectrometry). The Optimization of the system has been performed in terms of the determination of signal-to-noise ratio and background intensity at various rf powers, sample flow rates, argon gas flow rates and cut-off gas flow rates. The spectro-analytical characteristics of the spectrum obtained between 200 and 500 nm was revealed to be similar compared with a vertically viewed ICP source. The detection limit of Pb(Ⅱ) at 220.35 nm was 11 ppb which was 5 times lower than that obtained with a vertically viewed ICP source.

  • PDF

Hazardous Characteristics of metals in Bottom Ash from Municipal Solid Waste Combustors(MSWC) of Korea (도시폐기물 소각로에서 발생되는 바닥재중의 금속류 유해특성에 관한 연구)

  • Chung, David;Kim, Yu-Nung;Yun, Young-Ja;Kim, Yoen-Ho
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.253-258
    • /
    • 2001
  • This is a research on hazardous characteristics and potentials of bottom ash from 9 municipal solid waste combustors(200 tons/day) of Korea by the test methods of leaching and content. The leaching method was performed by Waste Test Method of Korea. In case of the content method, mercury was determined by thermal decomposition amalgamation atomic absorption spectrometer, other 9 elemets including Pb, which were pretreated by U.S.EPA SW-846 3050B method, were determined by flame atomic absorption spectrometer(FAAS) or inductively coupled plasma atomic emission spectrometer(ICP-AES). Results of leaching test showed that Pb and Cu was main pollutants. It was interested that the distribution rate of metals' contents of each combustors was similar and the rank of concentration was Fe>Zn>Cu>Mn>Pb>Cr>As>Cd>Hg.

  • PDF