• 제목/요약/키워드: Plant Parameters

검색결과 1,815건 처리시간 0.029초

適應制御裝置에 關한 硏究 (A Study of the Adaptive Control System)

  • 하주식;최경삼;김승호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.19-31
    • /
    • 1979
  • Recently the adaptive control system, which keeps the control system always optimal by adjusting the control parameters automatically according to the variations of the plant parameters, have become very important in the field of control engineering. The adaptive control systems are usally composed of the plant identification, the decision of the optimal control parameters, and the adjustment of the control parameters. This paper deals with a method of the adaptive control system when PI or PID controller is used in the feed back control system. Its controlled object (the plant) is assumed to be described by the transfer function of $\frac{ke^{-LS}}{1+TS}$ where k, T and L are steady state gain, time constant and pure dead time respectively, and their values are variable in accordance with the change of environmental circumstance. It has been known that a pseudo-random binary signal is quite effective for the measurement of an impulse response of a plant. In adaptive control systems, however, the impulse response itself is not appropriate to determine the control parameters. In this paper, the authors propose a method to estimate directly the parameters of the plant k, T and L by means of the correlation technique using 3 level M-sequence signal as a test signal. The authors also propose a method to determine the optimal parameters of the PI or PID controller in the sense of minimizing the square integral of the control error in the feed back control system, and the values of the optimal parameters are computed numerically for various values of T and L, and the results are examined and compared with those of the conventional methods. Finally the above-mentioned two methods are combined and an algorithm to struct an adaptive control system is suggested. The experiments for the indicial responses by means of both the model of the temperature control system using SCR actuater and the analog simulations have shown good results as expected, and the effectiveness of the proposed method is verified. The M-sequence generator and the time delay circuit, which are manufactured for the experiments, are operated in quite a good condition.

  • PDF

하수처리장 운전조건의 통계분석 (Statistical Analysis of Sewage Plant Operation)

  • 이찬형;문경숙
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.63-68
    • /
    • 2002
  • In this study, we examined statistical analysis between sewage plant operations parameters and effluent quality We got six components from principle component analysis of the operation parameters and secondary effluent quality. 91.8% of the total variance was explained by the six components. The components were identified in the following order : 1) organic matter removal by aeration basin microbe, 2) settleability on secondary clarifier load, 3) removal of nutrients, 4) microbial number increasement and species diversity, 5) microbial activity in aeration basin, 6) oxidation in aeration basin.

통계방법에 의한 하수처리장 운전분석 (Analysis of Sewage Plant Operation by Statistical Approach)

  • 이찬형;문경숙
    • 한국환경보건학회지
    • /
    • 제28권3호
    • /
    • pp.34-38
    • /
    • 2002
  • Statistical analysis between sewage plant operating parameters and the effluent quality was performed. We extracted two factors from principal component analysis of operating parameters and effluent quality from each plant. The total variance of 84.7%, 79.2% was explained by the two factors at SB plant and SC plant, respectively. The factors were identified at SB plant in the following order 1) the oxidation of organic material by aeration basin microbe,2) biomass in aeration basin and at SC plant 1) the oxidation of organic material by aeration basin microbe, 2) thickening of acti-vated sludge. These results suggested that the control of microbial composition might be critical on the improvement of the effluent quality and plant operating efficiency because most of the factors were related with microbes.

Reevaluation of Seismic Fragility Parameters of Nuclear Power Plant Components Considering Uniform Hazard Spectrum

  • Park, In-Kil;Choun, Young-Sun;Seo, Jeong-Moon;Yun, Kwan-Hee
    • Nuclear Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.586-595
    • /
    • 2002
  • The Seismic probabilistic risk assessment (SPRA) or seismic margin assessment (SMA) have been used for the seismic safety evaluation of nuclear power plant structures and equipments. For the SPRA or SMA, the reference response spectrum should be defined. The site-specific median spectrum has been generally used for the seismic fragility analysis of structures and equipments in a Korean nuclear power plant Since the site-specific spectrum has been developed based on the peak ground motion parameter, the site-specific response spectrum does not represent the same probability of exceedance over the entire frequency range of interest. The uniform hazard spectrum is more appropriate to be used in seismic probabilistic risk assessment than the site- specific spectrum. A method for modifying the seismic fragility parameters that are calculated based on the site-specific median spectrum is described. This simple method was developed to incorporate the effects of the uniform hazard spectrum. The seismic fragility parameters of typical NPP components are modified using the uniform hazard spectrum. The modification factor is used to modify the original fragility parameters. An example uniform hazard spectrum is developed using the available seismic hazard data for the Korean nuclear power plant (NPP) site. This uniform hazard spectrum is used for the modification of fragility parameters.

100MW 발전소 개조 보일러의 증기온도 제어 (The Steam Temperature Control of Renovated Boiler in 100MW Power Plant)

  • 임건표;이흥호
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1935-1940
    • /
    • 2011
  • The control logic of steam temperature was redesigned, tested and applied to the power plant after its steam temperature equipments had been revised. This power plant use the ancillary gas gotten in the process of making iron in the steel mill. The boiler of power plant has the superheater and reheater to make the superheated steam. The superheater and reheater have the spray valve to control their temperature. The reheater has the gas bypass damper additionally in this plant. The control logics were redesigned in cascade forms and the initial parameters of control logics were calculated from the several step tests. The final parameters could be obtained through the several repeated tests and the feedforward functions were added by temperature deviation and air flow. The power plant is being commercially-operated normally by improved control logics and It is expected that this improved controls help the efficiency improvement and safe operation of plant.

비최소 위상 특성을 갖는 유도탄의 기준 모델 적응 제어기 설계 (Model reference adaptive controller design for missiles with nonminimum-phase characteristics)

  • 김승환;송찬호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.624-629
    • /
    • 1993
  • In this paper, a model reference adaptive control scheme is applied to the normal acceleration controller for missiles with nonminimum-phase characteristics. The proposed scheme has an auxiliary compensator, an identifier of plant parameters and a feedback control law. First, plant parameters are estimated by the identifier and based the parameter estimates the coefficients of the compensator are calculated so that the estimated plant model with the compensator becomes minimum-phase. In this calculation, Nehari Algorithm is used. Parameters of the control law are then updated so that the extended plant model follows the given reference model. It is shown that the performance of the designed controller is satisfied via computer simulations.

  • PDF

반응표면분석법을 이용한 퍼지제어기의 설계 (Design of a Fuzzy Logic Controller Using Response Surface Methodology)

  • 김동철;이세헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.225-228
    • /
    • 2002
  • When the fuzzy logic controller (FLC), which is designed based on the plant model, is applied to the real control system, satisfactory control performance may not be attained due to modeling errors from the plant model. In such cases, the control parameters of the controller must be adjusted to enhance control performance. Until now, the trial and error method has been used, consuming much time and effort. To resolve such problem, response surface methodology (RSM), a new method of adjusting the control parameters of the controller, is suggested. This method is more systematic than the previous trial and error method, and thus optimal solutions can be provided with less tuning. First, the initial values of the control parameters were determined through the plant model and the optimization algorithm. Then, designed experiments were performed in the region around the initial values, determining the optimal values of the control parameters which satisfy both the rise time and overshoot simultaneously.

  • PDF

한국 표준형 원자력 발전소 증기터빈 보호 및 제어를 위한 운전인자 선정과 운전반 운영 (Selection of Operating Parameters and Management of Operation Console for Protection and Control of Steam Turbine in a Korea Standard Type Nuclear Power Plant)

  • 최인규;김종안;우주희;신만수
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.71-78
    • /
    • 2011
  • This paper contains the selection of operation parameters for protection and control of steam turbine in a Korea Standard Type Nuclear Power Plant. The safety of nuclear reactor must be ensured which generates nuclear energy and produces steam. Also, the safety of turbine, which consume the nuclear energy as a core machine, must be ensured. For the purpose of this, we describe how the operating parameters were selected, reviewed, implemented into the operator console and finally put into actual operation of the system.

Expert 형 제어기법에 의한 STC에 관한 연구 (A Study on the Implementation of STC using the Expert Control Functiona)

  • 채창현;이창훈;임은빈;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.584-589
    • /
    • 1988
  • Tuning of digital STC parameters for the system with unknown and time varying parameters as well as delays presents many preconditions and difficulties. In order to eliminate these difficulties and to enhance STC control functions, the present study employs the metbod of expert control for STC and to implement it in nod-minimum phase plants. In this paper, implimedtation of the Expert STC for process control, STC. parameters is carried out by tuning systematically and by applying these parameters to non-minimum phase plant. This controller supervises a status of the plant, and robust control function for time delay or change of the plant is demonstrated by computer simulations.

  • PDF

가변구조 적응모델 추종제어 시스템에 관한 연구 (A Study on the Variable Structure Adaptive Model Following Control Systems)

  • 허노재;최종문;한만춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1983년도 하계학술회의강연.논문초록집
    • /
    • pp.135-138
    • /
    • 1983
  • This paper studies a variable structure adaptive model following control system which can control a plant in which the parameters of the controlled plant can not be estimated because they vary with time and in which the controlled plant has noise. The values of the feedback gain matrices for given states are obtained the equivalent control law, and the adaptive controller has been designed using the adaptive mechanism which switches the matrices. The adaptive controller minimizes the state error vector, that is, the difference between the state vector of the model and the state vector of the controlled plant. A controlled plant which has time varying parameters, a controlled plant which has only noise, and a controlled plant which has both have been controlled by the designed adaptive controller. The continuous single input-output system has been analysed by computer. This control system may be used to control practical systems by the addition of a microcomputer.

  • PDF