• Title/Summary/Keyword: Plant Operation & Maintenance

Search Result 243, Processing Time 0.033 seconds

Development of Digital Twin platform using Smart Factory based CPPS (스마트팩토리 기반 CPPS를 활용한 Digital Twin 플랫폼 개발)

  • Lee, Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.305-307
    • /
    • 2021
  • In this paper, we propose a study related to the development of a Digital-Twin platform using a smart factory based CPPS (Cyber Pysical Production System) using ICT (Information Communication Technology) technology. The platform developed through this study performs a 3D model simulation function in conjunction with P3R (Product, Process, Plant, Resource) including BOP (Bill of Process) management function from the preceding manufacturing process planning stage. In addition, we propose a digital twin platform that can predict production processes, equipment, layout, and production. The platform proposed through this paper proposes a feature that can manage the entire smart factory manufacturing process from the initial planning design stage to the manufacturing, production, operation, and maintenance stages.

  • PDF

A study on the total cell count variation of commercial liquid seed by adding PAC and PAS (PAC 및 PAS 첨가에 따른 상업용 액상 종균제의 총균수 변화에 관한 연구)

  • 박미자;박경식;김승재
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2001
  • Commercial liquid seeds are used for supplying active microbial flora to organic wastewater treatment plants of high feed-to-microorganism ratio and to maintain optimal microbial condition during unsteady state operation of the biological wastewater treatment plant. In addition to bacterial cells, the liquid weeds contain various additives for special purposes as well as organic substrates for energy supply. The additives give physical stability for the maintenance of microbial decomposition activity and ability to control the overgrowth of seed strains. In this work, the effects of addition of two kinds of typical substrate additives, poly aluminum chloride(PAC) and poly aluminum sulfate(PAS) on the consitutional total cell counts(CFU/ml) of four kinds of reorganization liquid seeds(RLS I, RLS II, RLS III and RLS IV) were studied experimentally. The addition of PAC and PAS gave negative effect on TCC constitution for the four seeds studied.

  • PDF

Inspection of the Diagnosis Report for Life Assessment of Engine Generator (내연발전기 건전성 판정을 위한 종합 진단결과 고찰)

  • Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.96-99
    • /
    • 2010
  • This paper presents evaluating procedure for engine generator operated over 13 years which are usually installed at the island and therefore, isolated to the main distribution line. To decide continual operation of the generator, their diagnosis results should guarantee safety running. So the determination of criteria for continual usage or replacement is essential for economical and reliable maintenance. We present all the courses of evaluating the condition which includes the processes from acquiring basic data to comprehensive determination of generators. All the test was applied to serial number 3 generator in Jodo Engine Power Plant.

Development and Application of the Methodology to Establish Life Extension and Modernization Plan of Aged Hydropower Plants (노후 수력 발전소의 수명연장 및 현대화 계획 수립 방법론 개발 및 적용)

  • Kim, Jong-Sung;Kwon, Hyuck-Cheon;Song, Byung-Hun;Kwon, Chang-Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1171-1176
    • /
    • 2009
  • This paper provides how to establish an integrated plan for LE (life extension) and MD (modernization) of aged hydropower plants. The methodology is developed through review of overseas/domestic LE/MD histories, investigation of the previous overseas methodologies and consideration of domestic practices. The methodology includes reviews of the various factors such as condition, operation and maintenance history, up-to-date technology, and economic benefit. In order to establish the life extension/modernization plan, the methodology is applied to the domestic aged hydropower plants. Finally, priority rankings and draft practice plans for LE/MD are derived.

KHNP-JIT Development for the Effective Use of Nuclear Power Plant Operating Experiences (원자력발전소 운전경험 활용 증진을 위한 KHNP-JIT 개발)

  • Hur, Nam Young;Lee, Sang Hoon;Kim, Je Hun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.31-34
    • /
    • 2013
  • According to the increase in numbers and operation time of domestic Nuclear Power Plants, KHNP(Korea Hydro & Nuclear Power) has many operating experiences. These show that most of the accidents repeatedly occurred not by the new sources or mechanism like the Fukushima Accident, but by the human and equipment errors from normal habits, process, design, maintenance etc.. These lessons show that the well-established systematic approach is requested to take lessons from past experiences. For this reason, developed countries established INPO, WANO, COG as a non-profit professional organizations to actively share their operating experiences. KHNP is also trying to promote the utilization of operating experiences. As part of this effort, KHNP is developing the KHNP-JIT, reflecting the overseas JIT and the domestic experiences.

Study on the Fire Hazard and Risk Analysis Derived from the Plant Configuration Change During the Shutdown Period at Nuclear Power Plants

  • Jee Moon-Hak;Hong Sung-Yull;Sung Chang-Kyung;Jung Hyun-Jong
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.547-555
    • /
    • 2003
  • Fire hazard and risk analysis at Nuclear Power Plants is implemented on the basis of the normal operational configuration. This steady configuration, however, can be changed due to the temporary displacement of equipment, electric cable and irregular movement of workers through the fire compartments when the on-line maintenance is processed during the power operation mode or the scheduled outage mode for the refueling. With the consequence of this configuration change, the fire analysis condition and the evaluation result will be different from those that were analyzed based on the steady configuration. In this context, at this paper, the general items for the reassessment are categorized when the configuration has changed. The contemporary zone models for the detail fire analysis are also illustrated for their application for each classified condition.

Diagnosis of rotating machines by utilizing a back propagation neural net

  • Hyun, Byung-Geun;Lee, Yoo;Nam, Kwang-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.522-526
    • /
    • 1994
  • There are great needs for checking machine operation status precisely in the iron and steel plants. Rotating machines such as pumps, compressors, and motors are the most important objects in the plant maintenance. In this paper back-propagation neural network is utilized in diagnosing rotating machines. Like the finger print or the voice print of human, the abnormal vibrations due to axis misalignment, shaft bending, rotor unbalance, bolt loosening, and faults in gear and bearing have their own spectra. Like the pattern recognition technique, characteristic. feature vectors are obtained from the power spectra of vibration signals. Then we apply the characteristic feature vectors to a back propagation neural net for the weight training and pattern recognition.

  • PDF

A comparison of the operating characteristics of the synchronous generator and induction generator applied to the small hydroelectric power plant (소수력에 적용한 동기발전기와 유도발전기의 운전 특성 비교)

  • Kim, Jong-Gyeum;Kim, Young-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • In general, A synchronous generator is higher than the voltage stability of the induction generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So, coverage rate of the induction generator is gradually increasing in small hydroelectric power station rather than 1000kW recently. In order to increase the penetration of induction generator, pre-analysis of the operation of the generator is needed. In this study, we analyzed for the problems that occur when synchronous generator and induction generator of 1500kW is connected to the distribution system.

Abnormal vibration of steam turbine due to carbon deposit at journal bearing in 500MW thermal power plant (탄소 고형물에 의한 터빈의 이상 진동)

  • 구재량;황재현;김연환;이우광
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.234-238
    • /
    • 2002
  • Lubricating oil supply system is an essential instrument for safe turbine operation. A lubricating condition may cause the abnormal vibration of turbine. In this paper we have discussed the abnormal vibration of turbine due to lubricating oil. Dusts of the air usually attach to end of the oil deflector and contact particles of the bearing oil. Dusts which were contacted particles of the bearing oil were changed into carbon deposit because of high temperature. therefore, carbon deposits occur abnormal vibration of the turbine when they contact a rotor. So, we have solved this problems through the various maintenance.

  • PDF

EXCITATION SYSTEM MODERNIZATION OF THERMAL POWER PLANT

  • Kim, Chan-Ki;Kim, Jang-Mok;Rhew, Ho-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2024-2026
    • /
    • 1998
  • Many power plants built 20-30 years ago are facing problems associated with the excitation system used for controlling generator output voltage. After years of reliable operation, generation is experiencing increased down time due to maintenance associated with the exciting excitation equipment. Reliability of the excitation system has become an issue, especially where many of these generation plants may be critical to the internal processes used for manufacturing. Wear out mechanisms such as those associated with the wire wound rheostat the electromechanical voltage regulator, insulation failures of the rotating exciter and commutator deterioration have become real problems typical of many older installations. These are some of the issues that are affecting system reliability for older power plants. This paper will address typical problems associated with the old excitation systems and the justification for a replacement static excitation system used in many Paper Mills.

  • PDF