• Title/Summary/Keyword: Plane Rotation

Search Result 437, Processing Time 0.026 seconds

Strain localization and failure load predictions of geosynthetic reinforced soil structures

  • Alsaleh, Mustafa;Kitsabunnarat, Akadet;Helwany, Sam
    • Interaction and multiscale mechanics
    • /
    • v.2 no.3
    • /
    • pp.235-261
    • /
    • 2009
  • This study illustrates the differences between the elasto-plastic cap model and Lade's model with Cosserat rotation through the analyses of two large-scale geosynthetic-reinforced soil (GRS) retaining wall tests that were brought to failure using a monotonically increasing surcharge pressure. The finite element analyses with Lade's model were able to reasonably simulate the large-scale plane strain laboratory tests. On average, the finite element analyses gave reasonably good agreement with the experimental results in terms of global performances and shear band occurrences. In contrast, the cap model was not able to simulate the development of shear banding in the tests. In both test simulations the cap model predicted failure loads that were substantially less than the measured ones.

Effect on Audio Play Latency for Real-Time HMD-Based Headphone Listening (HMD를 이용한 오디오 재생 기술에서 Latency의 영향 분석)

  • Son, Sangmo;Jo, Hyun;Kim, Sunmin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.141-145
    • /
    • 2014
  • A minimally appropriate time delay of audio data processing is investigated for rendering virtual sound source direction in real-time head-tracking environment under headphone listening. Less than 3.7 degree of angular mismatch should be maintained in order to keep desired sound source directions in virtually fixed while listeners are rotating their head in a horizontal plane. The angular mismatch is proportional to speed of head rotation and data processing delay. For 20 degree/s head rotation, which is a relatively slow head-movement case, less than total of 63ms data processing delay should be considered.

  • PDF

Fiber Optic Gyroscope using IOC (IOC를 사용한 광파이버 자이로)

  • Kim, In-Soo S.;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1843-1845
    • /
    • 1998
  • Gyroscope is a very important core sensor as a rotation sensor in inertial space, in inertial guidance and navigation system on aeronautics. Plane, vessel and so on for civilian and millitary applications. Research and development of fiber optic gyroscope began in 1976 and focused on improving the gyroscope's sensitivity to rotation. bias performance and reducing noise. We have developed a Interferometric Fiber Optic' Gyroscope using a integrated-optic-circuit (IOC), which is operating with closed-loop electronic circuit. This paper describes the scheme of optical part and electronic part and also test results of this fiber optic gyroscope using a integrated-optic-circuit (IOC). The performance have been achieved as long-term bias drift of $1.73^{\circ}/h$.

  • PDF

Rotation-Invariant Pattern Recognition of the Multiple Circular Harmonic Filter Using Proper Center (적정의 중심점을 이용한 다중 원형 고조 필터의 회전 불변적 형태 인식)

  • 김종찬;도양회;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.1
    • /
    • pp.130-136
    • /
    • 1990
  • For the rotation-invariant pattern recognition, we propose multiple circular harmonic filter which is expanded about the proper center. The proper centerm when input image is given, is the circular harmonic expansion center of the filter which yields a maximum center correlation peak in the output plane. In this paper, we founded the circular harmonic components that the proper center superposes on the same position and then designed multiple circular harmonic filter using these components. Also the proposed filter is compared with conventional multiple circular harmonic filter and shows that it can maximize the center correlation peak for the rotated input image by the computer simulation.

  • PDF

Rotation of Orthotropy Axes under Plane Stress (평면응력하에서의 직교이방성 대칭축의 회전)

  • 인정제;김권희
    • Transactions of Materials Processing
    • /
    • v.3 no.3
    • /
    • pp.320-334
    • /
    • 1994
  • A set of full size cold rolled steel sheets has been prestrained in the direction of rolling by uniform tensile elongation of 3% and 6%. Then mid-sized tensile specimens were cut from each of the full size sheets at 30, 45, 60 and 90 degrees to the rolling direction. The mid-sized tensile specimens were then prestrained again by uniform tensile elongation by 1%, 2%, 5%, 10% and 15%. finally, miniature tensile specimens were prepared from each of the mid-sized specimens at every 10 degrees to the specimen axis. From the tensile tests on miniature specimens material's hardening behavior under non-proportional loading has been investigated. There are a number of new observations which has not been known to the authors before current work. One of them is continuous reservation of orthoropic symmetry during tensile elongation of mid-sized specimens. Another is continuous rotations of orthotropy axes. Existing theories seem to fail to explain this observations. A new model is proposed in relation to the rotation of orthotropy axes.

  • PDF

Spatial changes of the maxillary molar following unilateral derotation with the precision TPA (Precision TPA로 회전된 편측 구치 치료시 공간변화에 대한 연구)

  • Kim, You-Sun;Yeh, Seong-Pil;Kang, Dae-Woon;Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.34 no.3 s.104
    • /
    • pp.219-227
    • /
    • 2004
  • The purpose of this study was to evaluate the spatial changes of mesial-in rotated maxillary molar and opposite anchor tooth during derotation by the precision transpalatal arch (TPA) with the use of a new typodont simulation system, the Calorific machine system, which was designed to observe the whole process of tooth movement. The maxillary right first molar was used for the anchor tooth and the maxillary left first molar was used for the mesial-in rotated tooth, and the angle of rotation was increased to 20,40, and 60. A passive precision TPA was fabricated and then activated by bending the left arm to 20, 40, and 60. Each experiment was repeated five times under the same conditions and analyzed by ANOVA and Tucky's Studentized Range (HSD) test. In the occlusal plane, when the bending angle of precision TPA was increased, the mesiobuccal cusp of the rotated molar moved more buccally (p<0.001) and less distally (p<0.001) while the distolingual cusp moved in the mesiopalatal direction. In the sagittal plane, the palatal roots of the derotated molar moved mesially (p<0.001). In the traverse plane, the derotated molar showed slight extrusion (p<0.001). The upper right first molar, which was used as an anchor tooth, showed clinically insignificant movement across all three planes.

Kinematic Analysis of Lower Extremities during Stairs and Ramp Climbing with Older Adults (노인의 계단과 경사로 오르기 동안 하지의 운동학적 분석)

  • Han, Jin-Tae;HwangBo, Gak
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.435-448
    • /
    • 2009
  • The purpose of this study was to investigate the kinemaitc gait parameter of lower extremities with different gait conditions(level walking, stairs, ramp) in old adults. Fourteen healthy older adults participated in this study and kinematic data were measured using 3D motion analysis system(Vicon, Oxford Metrics, England). Statistical analysis was used one-way ANOVA to know the difference of lower extremities angle at each gait phase with a different gait conditions. In sagittal plane, pelvic anterior tilt increased in stairs and ramp climbing and hip and knee flexion increased in stairs climbing but ankle dorsiflexion increased in ramp climbing. In frontal plane, pelvic was up in stairs and hip abduction and adduction more changed in stairs climbing than level walking. Knee varus and ankle inversion increased in stair climbing. In horizontal plane, pelvic internal rotation increased in stairs and ramp climbing and knee internal rotation increased in stairs climbing but ankle external rotation increased in stairs climbing. This results was shown that the stairs and ramp climbing changed the kinematic gait parameters of lower extremities in healthy old adults.

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

Movement of a Horizontal Vortex Ring in a Circular Cylinder (원통 내 수평 보텍스 링의 거동)

  • Suh, Yong-Kweon;Yeo, Chang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.652-658
    • /
    • 2004
  • In this paper, we report the numerical and experimental solutions of the axi-symmetric flows in the axial plane driven by an impingement of fluid from the bottom wall of a circular cylinder. We managed to visualize successfully the flow pattern shown on the vertical plane through the container axis. The numerical results are shown to compare well with the experimental results for the case of infinity Rossby number. The satisfactory agreement between the two results was possible when in the numerics the free surface was treated as a solid wall so that a no-slip condition was applied on the surface. The numerical solutions reveal that inertial oscillation plays an important role at small Rossby numbers, or at a larger background rotation.

A Single Gap Transflective Display associated with In-Plane Switching Mode

  • Song, Je-Hoon;Lim, Young-Jin;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1179-1181
    • /
    • 2004
  • We have studied a single gap transflective liquid crystal display (LCD) associated with in-plane switching (IPS) mode. In the transmissive IPS cell, the transmittance of electrodes and above electrodes is different, that is, the degree of rotation of the LC director between electrodes and above electrodes is 45 $^{\circ}$ and 22.5 $^{\circ}$ , respectively. Utilizing the different rotating angle of the LC director and in-cell retarder with a quarter-wave plate used below the LC layer, the IPS transflective LCD is realized such that the area between electrodes is used as a transmissive part and the area above electrodes is used as a reflective part.

  • PDF