• Title/Summary/Keyword: Pipe-and-Filter

Search Result 77, Processing Time 0.024 seconds

Performance Evaluation of Manhole Filter to Remove Odor Inside Sewage Pipe -Focused on Removal of Hydrogen sulfide- (하수관거 악취 제거를 위한 맨홀필터 악취제거장치 성능 평가 - 황화수소 제거를 중심으로 -)

  • Kim, Choong-Gon;Lee, Jang-Hown
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.4
    • /
    • pp.45-51
    • /
    • 2018
  • The objective of this study is to evaluate the applicability of a manhole-filter odor eliminator that is installed on a manhole to remove hydrogen sulfide ($H_2S$) contained in the sewage of urban streets; $H_2S$ is the very cause of offensive odor from such sewage. An analysis of the capability of impregnated activated carbon, which is contained in the manhole filter, to adsorb hydrogen sulfide shows that some 99.8% of hydrogen sulfide can be removed. A performance evaluation of the manhole-filter odor eliminator, which was made on Manhole Section 4 known as the representative malodorous manhole section of Seoul, Korea, indicates that more than 97% of hydrogen sulfide ($H_2S$), one of typical malodor-generating substances, can be eliminated. The results and findings of the study as described above suggest that the applicability of the manhole-filter odor eliminator to eliminate offensive odor generated from sewer manholes is satisfactory.

The Real-Time Implementation of Two-Dimensional FIR Digital Filter using PiPe-Line Method (파이프라인 방법을 이용한 이차원 FIR 디지털 필터의 실시간 구현)

  • 윤형태;이근영
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.5
    • /
    • pp.27-33
    • /
    • 1993
  • This paper describes the hardware implementation of 2-D FIR digital filter for a real-time image processing. Generally, the most time-consuming operation in signal processing is the multiplication operation. To avoid it in digital filter. Pelid and Liu proposed the distributed arithmetic method for the one-dimensional case. The implementation method proposed in this paper is to extend Pelid's method to two-dimensional FIR filter using simple ROM lookup table and to use the technique of pipe lining two main operations of memory access and arithmetic. As a result, the speed of our proposed hardware implementation is two times faster than that of conventional methods and can be close to the real time speed.

  • PDF

Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures (내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구)

  • Kim, Ji-Hun;Yoon, Sangwoo;Kwon, Sung-Ho;Sung, Su-Hwan;Bae, Mun-Oh;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

Tracing of Some Root Colonizing Pseudomonas in the Rhizosphere Using lux Gene Introduced Bacteria (lux Gene을 도입한 생물적 방제 미생물의 근권 정착과 식물 생장 촉진 효과)

  • 김진우;최옥희;강지효;류충민;정미진;김재원;박창석
    • Korean Journal Plant Pathology
    • /
    • v.14 no.1
    • /
    • pp.13-18
    • /
    • 1998
  • The use of bioluminescence as a sensitive marker for the detection of Pseudomnas sp. in the rhizosphere was investigated. Transposon Tn4431 which contains a promoterless luciferase operon and tetracycline resistant gene was used. This transposon, present on a suicide vector (pUCD623) in E. coli HB101, was mated with spontaneous rifampicin mutant of Pseudomonas fluorescens B16, a plant growth promoting rhizobacteria (PGPR), and then rifampicin and tetracycline resistant survivors were isolated. Twenty tow mutants wer isolated from the conjugants between E. coli HB101 and P. fluorescens B16. One of these, B16::Tn4431 (L22) recombinant which glowed brightly in the dark was selected for analysis. The cucumber seeds inoculated with L22 were grown in moisten two layers of filter paper and nonsterile soil contained in half cut PVC pipe. The roots were removed from the filter paper and PVC pipe, then placed on the 1/2 LB media plates. The plates were incubated at room temperature for 16 hr. L22 could successfully be detected in the rhizoplane by using the ordinary negative camera film (ASA100-400) with 30 minutes exposure under dark condition. The root colonizing ability and the plant growth promoting effect of L22 were not reduced compared to the untreated bacteria and wild type. L22 was superior to will type.

  • PDF

Fundamental Experiment for the Development of Water Pipeline Locator (상수도관로 위치탐사 장비개발을 위한 기초실험)

  • Park, Sang-Bong;Kim, Jin-Won;Oh, Kyeong-Seok;Kim, Min-Cheol;Koo, Ja-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.253-261
    • /
    • 2016
  • A variety of methods for detecting the location of an underground water pipeline are being used across the world; the current main methods used in South Korea, however, have the problems of low precision and efficiency and the limitations in actual application. On this, this study developed locator capable of detecting the location of a water pipe by the use of an IMU sensor, and technology for using the extended karman filter to correct error in location detection and to plot the location on the coordinate system. This study carried out a tract test and a road test as basic experiments to measure the performance of the developed technology and equipment. As a result of the straight line, circular and ellipse track tests, the 1750 IMU sensor showed the average error of 0.08-0.11%; and thus it was found that the developed locator can detect a location precisely. As a result of the 859.6-m road test, it was found that the error was 0.31 m in case the moving rate of the sensor was 0.3-0.6 m/s; and thus it was judged that the equipment developed by this study can be applied to long-distance water pipes of over 1 km sufficiently. It is planned to evaluate its field applicability in the future through an actual pipe network pilot test, and it is expected that locator capable of detecting the location of a water pipe more precisely will be developed through research for the enhancement of accuracy in the algorithm of location detection.

Improvement of Pad Lifetime using POU (Point of Use) Slurry Filter and High Spray Method of De-Ionized Water (POU 슬러리 필터와 탈이온수의 고분사법에 의한 패드수명의 개선)

  • 박성우;김상용;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.707-713
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was requirdfo the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the IMD layer gest thinner, micro-scratches are becoming as major defects. However, as the IMD layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}{\textrm}{m}$ point of use (POU) filter, which is depth-type filter and has 80% filtering efficiency for the 1.0${\mu}{\textrm}{m}$ size particle. In this paper, we studied the relationship between defect generation and polished wafer counts to understand the exact efficiency fo the slurry filteration, and to find out the appropriate pad usage. Our experimental results showed that it sis impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the slurry flow rate, and to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of depth type filter.

  • PDF

Basic Study on the Flame Stability of Burner for Regeneration of Diesel Particulate Filter in Engine Exhaust Gas (DPF 재생용 버너의 엔진 배기 중에서의 화염 안정성 구현을 위한 기초 연구)

  • Shim, Sung-Hoon;Jeong, Sang-Hyun;Hong, Won-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.4
    • /
    • pp.10-17
    • /
    • 2005
  • Sustaining of flame stability of the burner installed in Dielsel exhaust pipe is very difficult because of steep fluctuation of pressure and flow rate. A burner for DPF (Diesel Particulate Filter) which clogged by collected soot regeneration has been made of metal fiber for the purpose of realization of flame stability even in unfavorable condition of Diesel engine exhaust. Flame stability of the metal fiber burner has been investigated in various condition of engine operation. It has been identified that metal fiber burner with liner which has swirl guide vane presents excellent flame stability even in the higher engine revolutions than 3000rpm and sudden variation. The results offer the possibility of development of full flow burner system for DPF regeneration.

  • PDF

Analysis of Filtration Characters Ceramic filter Collectors for PM removal of Diesel Engine exhaust gas (디젤엔진 배기가스의 PM저감용 세라믹필터 집진장치 여과특성에 관한 연구)

  • Lee, K.S;Kim, Ki ho;Oh, Jeong won;Lee, Young pill
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.151-152
    • /
    • 2012
  • Collectors connected to diesel engine exhaust pipe for application of PM reduction facilities which was used to reduce PM from the exhaust gas produced from ship, Filtration performance of PM was tested. In this system, it was confirmed that the bag house can remove over 90 percent of PM from a lot of high temperature and high pressure gases produced in diesel engine. The results obtained from performance test show the potential possibility for commercialization of ceramic filter collectors which is applied to reduction facilities of flue gas produced from a diesel engine on the ship.

  • PDF

Analysis on Vehicle Fires Caused by Damage of Diesel Particulate Filter (DPF) (매연저감장치 손상에 기인한 차량화재 사고사례 분석)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.70-76
    • /
    • 2012
  • This paper deal with vehicle fire caused by damage of diesel particulate filter (DPF) on diesel passenger vehicles. In order to reduce particulate matters included exhaust gases, a DPF in the exhaust system were installed diesel vehicles. A DPF was broken by excessively trapped particulate matters, regeneration error with a malfunction of ECU and defect of suction system such as swirl valve. If the DPF was broken, hot exhaust gases was released to the bottom of vehicle and released hot exhaust gases lead to occur the fire through combustible materials around the exhaust system. When a fire happened in the diesel vehicle caused by damage of DPF, silicate inorganic compounds were attached to the exhaust ventilation pipe and muffler. The silicate inorganic compounds were created by DPF combustion consisting of raw material ceramics. If the silicate inorganic compounds attached to the tail pipe in the diesel passenger vehicles, its fire cause will be assumed damage of DPF.

Leakage Detection of Water Distribution System using Adaptive Kalman Filter (적응 칼만필터를 이용한 상수관망의 누수감시 기법)

  • Kim, Seong-Won;Choi, Doo Yong;Bae, Cheol-Ho;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.969-976
    • /
    • 2013
  • Leakage in water distribution system causes social and economic losses by direct water loss into the ground, and additional energy demand for water supply. This research suggests a leak detection model of using adaptive Kalman filtering on real-time data of pipe flow. The proposed model takes into account hourly and daily variations of water demand. In addition, the model's prediction accuracy is improved by automatically calibrating the covariance of noise through innovation sequence. The adaptive Kalman filtering shows more accurate result than the existing Kalman method for virtual sine flow data. Then, the model is applied to data from two real district metered area in JE city. It is expected that the proposed model can be an effective tool for operating water supply system through detecting burst leakage and abnormal water usage.