• Title/Summary/Keyword: Pipe and Orifice System

Search Result 36, Processing Time 0.028 seconds

A Prediction of Gas Flow in a Pipe and Orifice System Using The Finite Difference Method and The Method of Characteristics (유한차분법과 특성곡선법을 이용한 파이프-오리피스계의 가스 유동 예측)

  • Na, H.S.;Koh, D.K.;Cho, K.H.;Jang, S.H.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.11-16
    • /
    • 2003
  • Because of the advancement of digital computers and software technologies, simulation methods have been used to reduce time and costs. A lot of simulation methods have been developed for the improvement of charging efficiency on the intake and exhaust system of engines. In this study, as a basic step for the development of the gas flow simulation program for the intake and exhaust system, the gas flow in a pipe-orifice system was calculated with three algorithms(Method of Characteristics, MacCormack Method for conservation, and MacCoramck Method for nonconservation). The calculated results using three numerical algorithms were compared with measured result to verify the calculation accuracy.

  • PDF

Analysis of Water Hammering in a Pipe Having an Accumulator

  • Suh, Yong-Kweon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.1
    • /
    • pp.19-30
    • /
    • 2002
  • This paper addresses characteristics of compressible flow dynamics inside a pipe with an accumulator and an inlet orifice. It also presents a simple but stable numerical method associated with the accumulator-orifice calculation. In particular, a focus is given to developing a method of finding an optimum design of the accumulator-orifice system (i.e., the accumulator size and the throttle resistance) that gives the most effective dissipation of the water-hammering problem. It is found that there exists indeed an optimum set of parameter values for the most effective dissipation of the wave energy.

Vibration Characteristics and its Countermeasure of Orifice Pipe for Reduction Gear Lubrication of Azimuth Thruster (아지무스 추진기의 감속 기어 윤활용 오리피스 파이프 진동특성과 방진대책)

  • Eam, Gitak;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.555-558
    • /
    • 2013
  • A type of electric propulsion employed by specialized purpose vessels or offshore is the azimuth thruster. Azimuth thruster application had been increasing recently and resulted to excellent vessel maneuverability. However, this system is very complex and some of its major component being exposed under the seawater level presents difficulty in sealing design. For Polar class icebreaker operating in extreme sea condition, this requires a high level of reliability and safety. In this study, the characteristics of lubricating orifice pipe structural vibration installed at the lower reduction gear were investigated and analyzed through beam analysis theory and comparison of experiments. Propeller excitation and the resonant modes of vibration causing excessive vibration and suitable countermeasures to prevent damage due to vibration fatigue on the pipe are presented.

  • PDF

Energy Loss and Flow Rate at Junction Pipe (합류관에서의 손실과 유량)

  • Kim, M.K.;Kwon, O.B.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.39-44
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF

Multiple Orifice Technique for Pressure Drop in Compressible Pipe Flows

  • Kim, Heuy-Dong;Koo, Byoung-Soo;Woo, Sun-Hoon;Setoguchi, Toshiaki
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.459-464
    • /
    • 2000
  • In order to investigate the effectiveness of an orifice system in producing pressure drops and the effect of compressibility on the Pressure drop, computations using the mass-averaged implicit Wavier-Stokes equations were applied to the axisymmetric pipe flows with the operating pressure ratio from 1.5 to 20.0. The standard k-e turbulence model was employed to close the governing equations. Numerical calculations were carried out for some combinations of the multiple orifice configurations. The present CFD data showed that the orifice systems, which have been applied to incompressible flow regime to date, can not be used for the hint operating Pressure ratio flows. The orifice interval did not strongly affect the total pressure drop but the orifice area ratio more than 2.5 led to high pressure drops. The total pressure drop rapidly increased in the range of the operating pressure ratio from 1.5 to 4.0, but it did not depend on the operating pressure ratio over 4.0.

  • PDF

Development of Optimal Design Program of Air-Coal Pneumatic Conveying System to Enhance Combustion Efficiency (연소효율 향상을 위한 공기-미분탄 수송배관장치의 최적화 설계 프로그램 개발)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.5
    • /
    • pp.7-14
    • /
    • 2009
  • This study describes to analyze the pressure drop characteristics for the air-particle flow in pneumatic coal powder conveying system and to proper design of the orifice located in the system to enhance combustion efficiency in furnace of the coal-fired power plant. Usually the system consists of the straight type pipe, the curved type pipe and the elbow, which cause increase of the pressure drop. In this study, the pressure drop arised in the system with straight and curved type pipes is analyzed with interactions of motion of air flow and particles. It is realized that total pressure drop increases with increasing of the pipe length and the angle of curved type pipe due to friction loss of air and particles in the system. The program for analysis of the pressure drop and optimum design of the orifice size for air flow control in the system is developed. The result is also compared with the existing system.

  • PDF

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.

Numerical Analysis of the Dynamical Characteristics of Fluid Flow Inside a Pipe with an Accumulator (축압기가 부착된 관로의 동특성 수치해석)

  • 서용권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.388-397
    • /
    • 2001
  • This paper addresses characteristics of compressible flow dynamics inside a pipe with an accumulator and an inlet orifice. It also presents a simple but stable numerical method associated with the accumulator-orifice calculation. In particular, a focus is given to developing a method of finding an optimum design of the accumulator-orifice system (i.e., the accumulator size and the throttle resistance) that gives the most effective dissipation of the water-hammering problem. It is found that there exists indeed an optimum set of parameter values for the most effective dissipation of the wave energy.

  • PDF

Stabilization of Water Balance of Closed Cooling Water System with Orifice (오리피스를 통한 기기냉각수 계통 Water Balance 정상화)

  • Lee, Sung Gun;Park, Jong Hwan;Lee, Eun Su
    • Plant Journal
    • /
    • v.13 no.4
    • /
    • pp.38-40
    • /
    • 2017
  • This study is for stabilization of the water balance of the closed cooling water system. The pipe network analysis program is used for the water balance review, and the resistance factor correction is performed through the field measurement with the ultrasonic flowmeter to improve the reliability of the pipe network software. Based on this, it is aimed to derive optimal driving method through various case simulations.

  • PDF

An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber

  • Lee, Jae-Soo;Yoon, Yong-Nam;Kim, Joong-Hoon
    • Korean Journal of Hydrosciences
    • /
    • v.7
    • /
    • pp.77-86
    • /
    • 1996
  • An air chamber is design to keep the pressure from exceeding a predetermined value, or to prevent low pressures and colum separation. Therefore, it can be used to protect against rapid transients in a pipe system following abrupt pump stoppage. In this research, an air chmber was applied to a hypthetical pipe system to analyze attenuation effect of pressure head for different air volumes, locations, chamber areas, coefficients of orifice loss and pollytropic exponents. With an increase of air volume, the maximum pressure head at pump site is decreased and the minimum pressure head is imcreased. For different locations and areas of the chamber, the attenuation effects do not show much difference. Also, as the orifice loss coefficient increases, the maximum pressure head is decreased. For different polytropic exponents, isothermal process shows lower maximum pressure head than that of the adiabatic process.

  • PDF