• Title/Summary/Keyword: Pipe Network Analysis

Search Result 154, Processing Time 0.027 seconds

Valve Openings and Minimum Pump Head for Precise Operation of Multiple Groundwater Injection Wells (군정의 주입량의 정밀 제어를 위한 유량조절밸브의 개도 및 최소 펌프 소요양정)

  • Park, Namsik;Jang, Chi Woong;Cho, Kwangwoo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.10
    • /
    • pp.869-877
    • /
    • 2015
  • Freshwater may be injected into aquifers to combat sea water intrusion in groundwater or to store water for later retrieval. For these cases to achieve the desired goal groundwater modeling is commonly used to determine locations and rates of injection wells. When these wells are connected to a pipe network, a flow control valve is installed for each well to regulate the injection rate. When a valve opening is modified, pressure changes in the entire pipe network and thereby changes flow rates in other wells. Therefore, desired valve openings must be determined for all injection wells. The pipe flow analysis allows estimation of the minimum pump power in addition to valve openings. Methods are developed to identify valve openings for multiple wells and the minimum pump power. The methodology developed in this work can contribute to precise operation of multiple injection wells.

A Study on the Analysis of the Leakage Characteristics and the Selection of Leakage Scenarios of the Blending Hydrogen into Natural Gas Pipeline (수소혼입 천연가스 배관망의 누출 특성 분석 및 누출 시나리오 선정에 관한 연구)

  • Song Su Tak;Ki Seop Lim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.27-32
    • /
    • 2024
  • This study analyzed cases of hydrogen (H2) and natural gas (CH4) leakage from a hydrogen-blended natural gas pipeline to determine a range of leakage characteristics, including leakage type, pipe material, pipe diameter, pressure, and damage size. Based on the results of this analysis, five hydrogen-blended natural gas leakage scenarios were selected. The national vision for a carbon-neutral society by 2050 is a very important strategic objective and promotes environmentally sustainable economic development in the age of the climate crisis. Accordingly, zero-carbon and low-carbon policies are being promoted in various fields, including energy production, consumption, and industrial processes. Hydrogen-blended natural gas is eco-friendly and is considered an important step towards carbon neutrality, with various countries including the United States and several European countries conducting empirical research to further investigate its potential. In Korea, a national research project commenced in April 2023 to verify and demonstrate the life cycle safety of blending hydrogen into the natural gas network. The results of this study will provide important data for the analysis of the damage impacts caused by the leakage of hydrogen-blended natural gas, such as the diffusion of gas clouds, fires, and gas explosions.

The Development of a GIS-based Sewer-network Analysis System (GIS를 이용한 하수관망해석시스템 개발)

  • Lee, Jung-Hun;Kim, Kye-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.2 s.12
    • /
    • pp.69-79
    • /
    • 1998
  • It is one of the most crutial thing to secure efficient infrastructure of social infrastructure Including rna drinking water, sewer, gas, and electricity, etc. in modern society. Among them, the sourer system need to be properly maintained so as to sustain water quality over the large watershed thereby to provide reasonable level of living environment A few municipalities and private firms have so in been using sewer management system for assessing existing sewer network and auxiliary facilities. Such existing system can only provide functions to manage the sewer pipe itself and they can not fully estimate the amount of sewage water over the pipe through 4he network analysis due to the deficiency of the system Such a limited sewer network analysis function can only analyze the whole network under the assumption of uniformity. The results from such a process can not be fully implemented in the field. Therefore, this study emphasized the development of a sewer management system which can provide practical values from network analysts considering areal peculiarities using a zoning map utilizing a GIS. The system can support analyzing scenarios due to the changes of sewer amounts from the changes of population densities and rainfall amounts not to mention of calculating sewer amount for individual sewer pipes. furthermore, the system can support the decision making for better designing sewer facilities from the expansion of metropolitan areas and constructing satellite cities. Eventually, it will contribute to enhance the effectiveness of sewer-related works and services for residents as well as supporting a decision making for minor and major trouble-shootings.

  • PDF

Analysis on Heat Supply Piping Network for Apartment House (아파트의 온수공급배관망해석)

  • 박윤철;황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Pipe Network Analysis by Using Frontal Solution Method (Frontal 기법을 이용한 상수관망의 흐름해석 모형)

  • 박재홍;한건연
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.141-150
    • /
    • 1996
  • Steady state analysis of pressure and flow in water supply piping systems is a problem of great importance in hydraulic engineering. The basic equations consist of continuity equation and energy equation. The network equations are solved iteratively by using linear solution method. The resulting linear simultaneous equations are solved by frontal method. Frontal method, which is suitable to sparse matrix, gathers only non-zero entries in coefficient matrix. The suggested methodology can analyze faster than the existing routines by using smaller computer memory. The model presented in this study shows accurate and efficient results for various piping systems.

  • PDF

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

Data-driven event detection method for efficient management and recovery of water distribution system man-made disasters (상수도관망 재난관리 및 복구를 위한 데이터기반 이상탐지 방법론 개발)

  • Jung, Donghwi;Ahn, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.703-711
    • /
    • 2018
  • Water distribution system (WDS) pipe bursts are caused from excessive pressure, pipe aging, and ground shift from temperature change and earthquake. Prompt detection of and response to the failure event help prevent large-scale service interruption and catastrophic sinkhole generation. To that end, this study proposes a improved Western Electric Company (WECO) method to improve the detection effectiveness and efficiency of the original WECO method. The original WECO method is an univariate Statistical Process Control (SPC) technique used for identifying any non-random patterns in system output data. The improved WECO method multiples a threshold modifier (w) to each threshold of WECO sub-rules in order to control the sensitivity of anomaly detection in a water distribution network of interest. The Austin network was used to demonstrated the proposed method in which normal random and abnormal pipe flow data were generated. The best w value was identified from a sensitivity analysis, and the impact of measurement frequency (dt = 5, 10, 15 min etc.) was also investigated. The proposed method was compared to the original WECO method with respect to detection probability, false alarm rate, and averaged detection time. Finally, this study provides a set of guidelines on the use of the WECO method for real-life WDS pipe burst detection.

Development of Optimal Decision-Making System for Rehabilitation of Water Distribution Systems Divided by small Division (상수관망의 구역별 최적개량 의사결정 시스템의 개발)

  • Baek Chun-Woo;Kim Seok-Woo;Kim Eung-Seok;Kim Joong-Hoon;Park Moo-Jong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.545-552
    • /
    • 2006
  • The purpose of this study is to develop an optimal, long-term planning model for improvement of water distribution networks. The water distribution system is divided into sub-zones and the decision of improvement plan is made for each sub-zone. Costs for replacement, rehabilitation and repair, benefits including reduced pumping and leakage costs, and hydraulic reliability are considered to make optimal decision for improvement planning of water network. Harmony search algorithm is applied to optimize the system and hydraulic analysis model EPANET is interfaced with the optimal decision model to check the hydraulic reliability, The developed model is applied to actual water distribution system in Daegu-city, South Korea. The new model which use durability, conveyance and cost as a decision variable is different from existing methods which use only burying period and pipe type and can be used as optimal decision making system for water distribution network.

A study on the use of fire hydrants as a heat wave reduction facility through hydraulic analysis of water supply network (상수관망 수리해석을 통한 폭염 저감 시설로써의 소화전 활용방안연구)

  • Hong, Sung Jin;Choi, Doo Yong;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1215-1222
    • /
    • 2021
  • In this study, a study on how to use a fire hydrant as a heat wave reduction facility through hydraulic analysis of the water supply pipe network was conducted. Assuming that the fire hydrant installation point is open for heat wave reduction, the water pressure at each point was derived. And the reduction rate of the temperature according to the hydrant watering was compared with the watering area according to the operation of the watering truck. The watering area according to the opening of the fire hydrant was calculated by deriving the pressure value at the node where the fire hydrant was installed through hydraulic analysis of the water pipe network, and then using the watering radius relational expression according to the pressure value. As a result of applying the proposed methodology to two real city areas, the temperature reduction effect of the watering method by a fire hydrant can be derived lower than the watering method by a watering truck according to the difference in the absolute watering area. However, unlike a watering truck, a fire hydrant does not have a relative restriction on the amount of water supply and is expected to allows continuous divided spraying of the same area.

Isolating Subsystems by Valves in a Water Distribution System and Evaluating the System Performance (상수관망에서의 밸브에 의한 관의 부분적 격리와 상수관망의 효율성 평가)

  • Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.585-593
    • /
    • 2005
  • Recent concerns regarding protecting, identifying, isolating, redundant routing and dewatering of subsystems of water distribution networks have led to the realization of the importance of valves in these systems. Valves serve two purposes namely, flow and pressure control and isolating subsystems due to breakage or contaminant containment. In this paper, valves are considered from the point of view of subsystem isolation. When a water main is required to be closed, it may be in general necessary to close several other pipes in addition to the broken pipe itself depending on the distribution of adjacent valves. This set of pipes is defined as a segment. In this paper a segment analysis for isolating pipes is present and based on the segment analysis, we suggested the Valve Importance Index and the 7 performance indicators to evaluate the system performance. The suggested methodology is applied to a real network to verify the applicability of the methodology.