• Title/Summary/Keyword: Piezoelectric Gas Sensor

Search Result 19, Processing Time 0.025 seconds

Design and Resonant Characteristics of the Ultrasonic Sensor for Gas Flowmeter (기체유량계용 초음파 센서의 설계 및 공진 특성)

  • Hong, Jae-Il;Lee, Sang-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.193-197
    • /
    • 2002
  • In this paper, the ultrasonic sensor for gas flowmeter was simulated, fabricated and measured according to the assembly step and the piezoelectric vibrator layers. The simulated resonant frequency and the measured resonant frequency were similar except two layer sensor. The simulated resonant frequency of three layer sensor was 48 kHz and the measured resonant frequency of three layer sensor was 45.2 kHz. From the results, the ultrasonic sensor for gas flowmeter could be designed and expected without fabrication.

Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde (Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

Development of the Ultrasonic Sensor for Gas Flowmeter (기체유량계용 초음파 센서 개발)

  • Hong, Jae-Il;Lee, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.131-134
    • /
    • 2002
  • In this paper, the ultrasonic sensor for gas flowmeter was simulated, fabricated and measured with assembly step and piezoelectric vibrator layers. The simulated resonant frequency and the measured resonant frequency were similar except sensor 2. The simulated resonant frequency of sensor 3 was 48 kHz and the measured resonant frequency of sensor 3 was 45.2 kHz. From the results, the ultrasonic sensor for flowmeter could be designed and expected without fabrication.

  • PDF

Development of environmental gas sensors (환경가스센서의 개발)

  • 정일형;김진사;이수길;박건호;이준웅
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.816-822
    • /
    • 1995
  • 본 고에서는 지구환경문제에 관련된 가스와 그들의 검지를 위한 가스센서에 관하여 살펴보고자 한다. 환경오염을 방지하려는 노력과 대책이 전세계적으로 추진되고 있는 시점에서 특히 대기오염의 주범인 환경가스에 대한 고성능 센서의 개발은 필수불가결하다. 그러나 현재에 사용되고 있는 환경가스센서는 차량의 배기계통에 사용되는 산소센서나 연소배출가스를 검지하는 소수의 가스센서외에는 아직 실용화되지 못하고 있다. 따라서 고온, 부식등의 과혹한 조건하에서 안정하고, 고성능의 센서의 개발은 물론 센서를 구동시키는데 필연적인 신호처리 등 주변기술 또한 병행해서 발달되어야 할 것이다.

  • PDF

A Study for Control using DC Gain and Time Constant of Flow Controller Operated by Piezoelectric Actuator and Thermocouple (열전대 센서와 압전체 구동기가 부착된 유량제어기의 DC 이득과 시상수를 이용한 제어에 대한 연구)

  • Lee, Sang-Kyung;Kim, Young-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.79-83
    • /
    • 2004
  • This study was how to control the mass flow controller in gas supplying system. The flow controller consists of piezoelectric material and sensor with heating wire. It is difficult to obtain accurate model, because MFC was composed of many parts, and the relationship between input and output of controller is nonlinear. The model for control was obtained by time constant and DC gain Based on this model, PID controller was applied to flow controller using DSP board. Also, the results were compared to controller using system identification.

  • PDF

Fabrication and Characteristics of Surface-Acoustic-Wave Sensors for Detecting $NO_2$ GaS ($NO_2$ 가스 감지를 위한 표면탄성파 센서의 제작 및 특성)

  • Choi, D.H.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 1999
  • Surface acoustic wave (SAW) device is very attractive for gas sensor applications because of their small size, low cost, high sensitivity, and good reliability. A dual delay line surface acoustic wave $NO_2$ gas sensors have been designed and fabricated on the $LiTaO_3$ piezoelectric single crystal substrate. The capacitance of the fabricated IDTs was 326.34pF at the frequency of 79.3MHz. The maximum reflection loss of the impedence-matched IDTs was -16.74dB at the frequency of 79.3MHz. The SAW oscillator was constructed and the stable oscillation was obtained by controlling the gain of rf amplifier properly. The oscillation frequency shift of the SAW oscillator to the $NO_2$ gas was 28Hz/ppm.

  • PDF

Effect of the Unmixedness of Fuel and Air on the Pressure Fluctuations in a Model Gas Turbine Combustor (연료와 공기의 혼합정도가 모델 가스터빈 연소기내의 압력변동에 미치는 영향)

  • Hong, Jung-Goo;Shin, Hyun-Dong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3264-3269
    • /
    • 2007
  • Combustion instability is a serious obstacle for the lean premixed combustion of gas turbines, and can even cause fatal damage to the combustor and the entire system. Thus, improved understanding of the mechanisms of combustion instability is necessary for designing and operating gas turbine combustors. In this study, in order to understand the instability phenomena, an experimental study was conducted in a rearwardstep dump combustor with LPG and air. The fluctuations of pressure and heat release were measured by piezoelectric pressure sensor and High speed Intensified Charge Coupled Device (ICCD) camera respectively. Various types of combustion modes occurred in accordance with the equivalence ratio and the fuel supplying conditions. The unmixedness of the fuel and air can be controlled by changing the mixing distance ($L_{fuel}$). It is found that the unmixedness of the fuel and air affects the characteristics of flame behavior and pressure fluctuations in a lean premixed flame.

  • PDF

기포탑반응기에서 가스 SENSOR 재료인 PZT 분말의 합성(I)

  • 현성호;김정환
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.40-51
    • /
    • 1996
  • A synthesis process for PZT powder using NH$_3$ gas as a precipitator in a bubble column reactor was experimentally successful in develope a production process of Piezoelectric ceramic PZT powder. Also as a reaction by coprecipitation, the crystalized PZT ceramic powder at the condition of over pH 9 could be attained. The time needed for reaction on the condition of NH$_3$ gas flow rate=0.5 1/min, Ar gas flow rate=2.0 1/min, Feed flow rate=2.33 ml /sec was less than five minutes, so it could synthesize PZT powder for such a few moments. And the synthesized PZT powder was 0.17${\mu}{\textrm}{m}$ in diameter on an average.

  • PDF