• Title/Summary/Keyword: Pieces

Search Result 2,087, Processing Time 0.035 seconds

Development of roll bending process technology applied precision orthogonal feeding robot system (정밀 직교 피딩 로봇시스템 적용 롤 밴딩 공정 기술 개발)

  • Lim, Sang-Ho;Ahn, Sang-Jun;Yun, Gyeong-Yeol
    • Industry Promotion Research
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2022
  • This study evaluated the automated system of the roll bending process, which is one of the difficult processes. In the past, 20 cartridges were produced per hour. but Automation changed it to a process that produces 50 pieces per hour. The average value of production was 57.6 pieces per hour, error of repeatability was 0.03 mm, average roll diameter error value was 0.49 mm, average alignment error value was 0.09 mm and average process lead time was 43.21 seconds. This paper presented specific evaluation methods such as productivity, repeatability, defect rate, alignment defect rate, and process lead time. It is thought that the contents performed in this study will be helpful in the verification of other automation systems in the future.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.

An Analytical Study of Claude Debussy's (클로드 드뷔시의 <잊혀진 영상>에 관한 분석 연구)

  • Kim, Hee Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.43-50
    • /
    • 2022
  • Claude Debussy's is a solo piano piece written in 1894. However, for unknown reasons, the entire piece was not published until 1977, despite clear evidence that Debussy intended to publish it during his lifetime. Interestingly, the second movement of the three pieces comprised in the work was published independently in February 1896 through the Parisian periodical Le Grand Journal. Partly because the work was recently published, it remains relatively more unknown to pianists and music lovers than other piano solo pieces by Debussy. Thus, this article addresses in detail the compositional background of this work, focusing on why the work was not published during Debussy's lifetime. Furthermore, by analyzing this piece in detail, this article intends to discuss the stylistic characteristics of the work regarding its melody, phrase structure, harmony, and form. This survey, which would help understand the musical style embodied in this piece, aims to contribute to improving the awareness of the work.

The weight values and their implications of dosages in the Decoctions of 《Treatise on Cold Damage Diseases》 that were likened to an object (《상한론》 탕제에서 사물에 비유한 복용량을 무게로 환산한 값과 의미)

  • In-Rak Kim
    • The Korea Journal of Herbology
    • /
    • v.38 no.4
    • /
    • pp.1-9
    • /
    • 2023
  • Objectives : This study aimed to convert into weight the dosages of flower of Daphne canescens and leaf of Phyllostachys nigra var. henonsis, whose daily dosages are likened to an object in 《Treatise on Cold Damage Diseases》. This study also aimed to understand their implications along with the previously studied gypsium and rhubarb. Methods : After reviewing documents, the dosages were converted into weight, confirmed by experiment, and their implications were considered. Results : A chicken-egg-volume of flowers of Daphne canescens is one Ryang(6.5 g) and two handfuls of leaves of Phyllostachys nigra var. henonsis is four Ryang(13 g). Each item was only used once in a decoction. Their dosages were expressed in weight respectively in 《Supplement to the Essential Prescriptions Worth a Thousand Gold》 and 《Bohenggyuljangbuyongyakbubyo》. Gypsium dosage was expressed in weight except in Daecheongryong-tang as chicken-egg-volume(16 Ryang). To liken a dosage to an object is an exception, as in the three cases above; for precision and convenience it is recommended that dosages be expressed in weight, in which case all three items fell into one of eight categories from one Ryang to 16 Ryang. Rhubarb was measured in weight, but only when using the 12-hour leaching method, four Ryang of rhubarb was cut into of 5-6 wide-go-stone-sized pieces and two Ryang into 5-6 go-stone-sized pieces. Conclusions : To liken a dosage to an object is only an exception and lacks precision and convenience; therefore dosages ended up expressed in weight, count, or volume.

A Study on the Geomorphic Landscape of Yeongdong Area Described in the Haedong Myeongsan Docheop (해동명산도첩에 나타난 영동지역 지형 경관에 대한 연구)

  • Shin, Won Jeong;Kim, Jong Yeon
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.4
    • /
    • pp.53-70
    • /
    • 2020
  • Silgyeong sansuhwa (Realistic landscape paintings) are drawn in Korea since 17th century. It has characteristics of more realistic description of landscape than painting from previous periods. Kim Hong Do's 'Haedong Myeongsan docheop (The album of paintings of famous mountains in Korea)' has been recognized as fine example of realistic description of geomorphic landscapes. Kim Hong Do and Kim Eung hwan did official travel to Gwandong and Geumgangsan area by order of King Jeongjo in 1788. As a result of that travel they draw about 100 piece of landscape painting. About 60 pieces of the paintings are still remaining. These are open to public by Korea National Museum in 1996. 14 pieces of painting, Daegwanryeong and Gangneung, Gyeongpo-dae, Hohae-jeong, Gahak-jeong, Cheonggan-jeong, Mun-am, Mangyang-jeong, Wolsong-jeong, Neungpa-dae, Naksan-sa, Mureung-gye, Gyejo-gul, and Hyeonjong-am, are analysed in this study. Coastal depositional landforms, like lagoon, sand beach and spit or barriers, erosional forms, like sea stack, sea cliff and sea cave, depicted in the paintings are analysed. In addition, structural landforms, colluvial landform and bedrock incision form by the running water in mountain area were analysed and weathered forms of granite and excursion to karst cave also discussed. It is found that sea arch in the printing destroyed since 1788, though exact position and reason is still unknown. There are strong need for discovery and identification of geomorphic landscape resources, for applied geomorphological studies and for prepare educational materials for non-face-to-face education. It also be emphasized that it can be used of the course work materials for future education using augmented reality and virtual reality technology.

Behavior of simple precast high-strength concrete beams connected in the maximum bending moment zone using steel extended endplate connections

  • Magdy I. Salama;Jong Wan Hu;Ahmed Almaadawy;Ahmed Hamoda;Basem O. Rageh;Galal Elsamak
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.627-641
    • /
    • 2024
  • This paper presents an experimental and numerical study to investigate the behavior of the precast segmental concrete beams (PSCBs) utilizing high-strength concrete (HSC) connected in the zone of the maximum bending moment using steel extended endplate connections (EECs). The experimental study consisted of five beams as follows: The first beam was the control beam for comparison, which was an unconnected one-piece beam made of HSC. The other four other beams consisted of two identical pieces of precast concrete. An important point to be noted is that at the end of each piece, a steel plate was used with a thickness of 10 mm. Moreover, this steel plate was welded to the lower and upper reinforcing bars of the beam. Furthermore, the steel plate was made to connect the two pieces using the technique of EECs. Several variables were taken in these four beams, whether from the shape of the connection or enhancing the behavior of the connection using the post-tensioning technique. EECs without stiffeners were used for some of the tested beams. The behavior of these connections was improved using stiffeners and shear bolts. To get accurate results, a comparison was made between the behaviors of the five beams. Another important point to be noted is that Abaqus and SAP2000 programs were used to investigate the behavior of PSCBs and to ensure the accuracy of the modeling process which showed a good agreement with the experimental results. Additionally, the simplified modeling using SAP2000 was able to model the nonlinear behavior of PSCBs connected using steel EECs. It was found that the steel pre-tensioned bolted EECs, reinforced with steel stiffeners and shear anchors, could be used to connect the precast HSC segmental beams via the internal pre-stressing technique.

Application of a traction metal clip with a fishhook-like device in wound sutures after endoscopic resection

  • Wang Fangjun;Leng Xia;Gao Yi;Shen Xiuyun;Wang Wenping;Liu Huamin;Liu Pengfei
    • Clinical Endoscopy
    • /
    • v.55 no.4
    • /
    • pp.525-531
    • /
    • 2022
  • Background/Aims: Endoscopic wound suturing is an important factor that affects the ability to remove large and full-thickness lesions during endoscopic resection. We aimed to evaluate the effect of a traction metal clip with a fishhook-like device on wound sutures after endoscopic resection. Methods: From July 2020 to April 2021, patients who met the enrollment criteria were treated with a fishhook-like device during the operation to suture the postoperative wound (group A). Patients with similar conditions and similar size wounds who were treated with a "purse-string suture" to suture the wounds were retrospectively analyzed as the control group (group B). Difference in the suture rate, adverse events, time required for suturing, and number of metal clips were compared between the two groups. Results: The time required for suturing was 7.72±0.51 minutes in group A and 11.50±0.91 minutes in group B. This difference was statistically significant (F=13.071, p=0.001). The number of metal clamps used in group A averaged 8.1 pieces/case, and the number of metal clamps used in group B averaged 7.3 pieces/case. This difference was not statistically significant (F=0.971, p=0.331). Conclusions: The traction metal clip with the fishhook-like device is ingeniously designed and easy to operate. It has a good suture effect on the wound after endoscopic submucosal dissection and effectively prevents postoperative adverse events.

A Study on the Environmental Condition and Safety in Dental Radiographic Room (치과 방사선 촬영실의 촬영실태와 방사선 안전관리 실태에 관한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Ju, On-Ju
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Regarding the intraoral radiographic method, the average daily photographing frequency of standard films stood at one to five pieces (47.5%), and the average weekly photographing frequency of digital radiation medicine stood at less than one piece (69.8%), and the average weekly photographing frequency of bitewing films stood at less than one piece (67.7%), and and the average weekly photographing frequency of occlusal films stood at less than one piece (95.5%), and the dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 47.1 percent. 2. Regarding the extraoral radiographic method, the average weekly photographing frequency of panorama film stood at one to five pieces (63.7%), and less than one piece (20.9%), the average weekly photographing frequency of cephalometric film stood at less than one piece (72.3%), and one to five pieces (20.1%). 3. Concerning the radiation safety management training program, only 18.7% of total 278 surveyed attended the training progra., Attendance tendency of the training program by general characteristics showed statistically significant difference according to age (p<0.01), working experience (p<0.001), and marital status (p<0.01). 4. When asked about the protective equipments against radiation exposure, 40.6% of them said "modest", and 71.1% appeared equipped with led apron as a protective tool.

  • PDF

THE EFFECTS OF SURFACE TREATMENT OF DENIAL NICKEL-CHROMIUM ALLOY ON TENSILE BOND STRENGTH (치과용 니켈-크롬합금에 대한 표면 처리가 인장접착강도에 미치는 영향)

  • Lee, Eun-Suk;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.493-502
    • /
    • 1997
  • This study was conducted to evaluate the tensile bond strength by bonding the dental bracket with Super-bond after treating the surface of dental Nickel-Chromium alloy with sandblasting, sandblasting & tin-plating, respectively, and tin-plating. 10 pieces of Nickel-Chromium alloys with brackets bonded with Super-bond without their surface treatment were sampled as a control group, 20 pieces of Nickel-Chromium alloy brackets bonded with Super-bond after treating them with sandblasting as group I, 20 pieces of Nickel-Chromium alloys tin-plated and bonded with Super-bond after sandblasting as group II, and then 20 pieces of alloys with brackets bonded with Super-bond after tin-plating as group III. The result of those examination and comparison is summarized as follows: 1. Group I showed the mean tensile bond strength of $14.41{\pm}2.24MPa$ which was highest among 4 groups, followed by group III($13.59{\pm}.51MPa$), group II($12.27{\pm}.45MPa$), and control group($10.50{\pm}1.57MPa$), respectively. However, it was shown that there was no statistically significant difference between group I and III, group III and II, and group II and control group(p>0.05). 2. The main failure pattern of those brackets showed that $70\%$ of the control group had an adhesive failure at the bracket-Superbond interface, and $30\%$ at the Nickel-Chromium alloy-Superbond interface, while other groups did the adhesive failure at the bracket-Superbond interface. 3. When examined under SEM, it was shown that adhesives were mostly attached to the surface of the Nickel-Chromium alloy for all groups while a considerable quantity of adhesives were attached to the bracket base. Then, those samples treated only with sandblasting showed the most even and remarkable roughness of their surface.

  • PDF

Bionomics and a Lana Sampling Method of Coppery Wireworm, Selatosomus puncticollis (Motschulsky), (Coleoptera: Elateridae) in Potato Field (청동방아벌레(Selatosomus puncticollis Motschulsky)의 생태적 특성 및 감자포장내 유충밀도 조사법)

  • Kwon, Min;Park, Cheon-Soo;Lee, Seung-Hwan
    • Korean journal of applied entomology
    • /
    • v.43 no.3 s.136
    • /
    • pp.195-200
    • /
    • 2004
  • The occurrence pattern and bionomics of Selatosomus puncticollis (Motschulsky) were surveyed in three net house (6$\times$70m) in the field and in a laboratory ($20^{\circ}C$, RH$75\%$, L16/DB). Emergence of hibernated adults of S. puncricollis started from early May, reached peak at early June and diminished in late June. Occurrence rate to total number was $42.1\%$ in early June and $31.7\%$ in late May, when most of hibernated adults emerged at these periods. Adults started to oviposit from mid June, and eggs hatched from early July Larvae turned into pupae from mid July and emerged to adults from mid August. Egg-period was 23 days and pupal period was 21 days. It is estimated that preovipositional period and larval period were approximately 10 months and 30 months, respectively. Wireworms were distributed at the soil depth of 10-5 cm, $56.8\%$ in 1997 and $45.8\%$ in 1998. To establish bait techniques to attract wireworms in the soil, six baits: pieces of potato, carrot, and sweet potato, wheat grains, corns, and flour dough wrapped with gauze, were buried at 15 cm of soil depth, and collected after 5 and 10 days. The numbers of wireworms attracted by potato pieces, wheat grains and sweet potato pieces after 10 days were 1.8, 1.6, and 1.4/bait, respectively. Therefore, burying potato pieces at 15 cm of soil depth and collected after 10 days could be recommended as a wireworm baiting technique.