• 제목/요약/키워드: Photovoltaic performance

검색결과 860건 처리시간 0.029초

PV 일체형 태양광발전 광선반시스템의 성능평가 (The Performance Evaluation of Photovoltaic-integrated Lightshelf Systems)

  • 박훈;정유근;김정태
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.129-134
    • /
    • 2012
  • The lightshelf system, a daylighting device, has been applied to improve the visual environment by optimal light distributions and intense illumination levels of a interior. Also, The photovoltaic is one of the most important sustainable technologies appliable to architectures. This study aims to evaluate the performance of photovoltaic integrated lightshelf system. For the study, the 1/5 scaled office models were made and the field tests were experimented under clear sky conditions. The power ratio has been analyzed to evaluate the performance of photovoltaic integrated lightshelf system. As results, the power performance was high on photovoltaic lightshelf installation angle $0^{\circ}$. And the performance was reduced on 23(%) by installation angle $15^{\circ}$ and 63(%) by installation angle $30^{\circ}$.

해석모델을 이용한 태양광모듈의 성능결과 비교분석 (Comparison Results of Photovoltaic Module Performance using Simulation Model)

  • 소정훈;유병규;황혜미;유권종
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.56-61
    • /
    • 2008
  • The modeling of PV (Photovoltaic) module is useful to perform detailed analysis of PV system performance for changing meteorological conditions, verify actual rated power of PV system sizing and determine the optimal design of PV system and components. This paper indicates a modeling approach of PV module performance in terms of meteorological conditions and identifies validity of this modeling method by comparing measured with simulated value of various PV modules using simulation model.

추적식 수상 태양광 발전 시스템 성능 분석 (The Efficiency Analysis of Tracking-Type Floating PV System)

  • 양연원;정선옥;신현우;이길송
    • Current Photovoltaic Research
    • /
    • 제1권2호
    • /
    • pp.122-125
    • /
    • 2013
  • The Floating Photovoltaic System was installed on the surface of water. There were some researches in this subject. But there was not many studies with experiment on a high waterproof Floating Photovoltaic modules. The aim of this study was to analyze the performance of the Floating Photovoltaic System. For this experiment, a high waterproof Floating Photovoltaic modules were designed and applied to the module capacity of 10 kW Tracking-Type structure. The experiment results indicated the performance of the daily production is 51.6 kW; the production capacity of Floating Photovoltaic System is expected to be 23% higher than that of the ground-mounted photovoltaic system.

Isoindigo Based Small Molecules for High-Performance Solution-Processed Organic Photovoltaic Devices

  • Elsawy, W.;Lee, C.L.;Cho, S.;Oh, S.H.;Moon, S.H.;Elbarbary, A.;Lee, Jae-Suk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.245.2-245.2
    • /
    • 2013
  • Solution processed organic photovoltaic devices have relatively less attention compared to polymer photovoltaic devices even though they have high possibility to be developed because they have both advantages of polymer and organic, such as solution processable, no synthetic batch dependence of photovoltaic performance, high purity and high charge carrier mobility as well as relatively high efficiency (~7%). In addition, solution processed organic photovoltaic devices have an advantage of easiness to study the relationship between the molecular structure and photovoltaic performance due to its simple structure. In this work, five isoindigo based low band gap donor-acceptor-donor (D-A-D) small molecules with different electron donating strength were synthesized for investigating the relationship between the molecular structure and photovoltaic performance, especially, investigating the effects of different electron donating effect of donor group in isoindigo backbone to photovoltaic device performance. The variation of electron donating strength of donor group strongly affected the optical, thermal, electrochemical and photovoltaic device performances of isoindigo organic materials. The highest power conversion efficiency of ~3.2% was realized in bulk heterojuction photovoltaic device consisted of the ID3T as donor and PC70BM as acceptor. This work demonstrates the great potential of isoindigo moieties as electron deficient units as well as guideline for synthesis of donor-acceptor-donor (D-A-D) small molecules for realizing highly efficient solution processed organic photovoltaic devices.

  • PDF

PV모듈 모델링에 의한 성능모의 결과비교 (Performance Simulation Results for Photovoltaic Module Modeling)

  • 소정훈;유병규;황혜미;유권종;최주엽
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1988-1993
    • /
    • 2008
  • Photovoltaic (PV) modules operate over a large range of conditions but manufacturer's information is not sufficient to determine their overall performance. Designers need a reliable tool to predict energy production from a photovoltaic module under all conditions in order to make a sound decision. The modeling method of photovoltaic (PV) module are useful to perform detailed analysis of PV system performance for changing meteorological conditions, verify actual rated power of PV system sizing and determine the optimal design of PV system and components. This paper indicates a modeling approach of PV module performance in terms of meteorological conditions and identifies validity of PV modules modeling by comparing measured with simulated value.

태양광발전시스템의 장기운전에 의한 성능특성 분석 (The Long-term Operating Evaluation of the Grid Connected Photovoltaic System)

  • 김의환;강승원;김재언
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

계통연계형 태양광발전시스템의 손실 산출방법 (Loss Calculation Method of Grid-Connected Photovoltaic System)

  • 소정훈;임현묵;황혜미;정영석;고석환;주영철
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.18-23
    • /
    • 2013
  • This paper presents a simple but valid loss calculation method of grid-connected photovoltaic system based on normalized yield model. The proposed method can be represented as a quantitative value for five losses and performance of grid-connected photovoltaic system with three years monitored data. These results will indicate that it is useful to investigate various loss factors causing the performance obstruction, enhance the lifetime yield for changing meteorological conditions, and determine the optimal design and performance improvement of grid-connected photovoltaic system.

50kW급 계통연계형 태양광발전시스템의 성능모니터링 결과 및 평가분석 (Performance Monitoring Results, Evaluation and Analysis of 50kW Grid-Connected PV System)

  • 소정훈;유병규;황혜미;유권종;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2007
  • Monitoring system is constructed for evaluating and analyzing performance of installed 50kW grid-connected PV system and have been monitored since October 2005. As climatic and irradiation conditions have been varied through long-term operation, there is necessity for evaluating numerical values of PV(Photovoltaic) system performance to observe the overall effect of environmental conditions on their operation characteristics. This paper presents performance monitoring results and analysis on component perspective(PV array and power conditioning system) and global perspective(yield, losses) of PV system for one year monitoring periods.

12kW급 건물일체형 태양광발전시스템 사례분석 (Case Study on 12kW Building Integrated Photovoltaic System)

  • 박경은;강기환;김현일;소정훈;유권종;김준태;이길송
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

양면형 태양광발전 소자의 성능변수 및 이에 대한 정확한 측정방법 (Performance Parameters of a Bifacial PV Device and Accurate Measurement Method for the Parameters)

  • 안승규;안세진;어영주;유진수;박주형;김기환;조아라;조준식;윤재호;신동협;정인영;곽지혜
    • Current Photovoltaic Research
    • /
    • 제5권3호
    • /
    • pp.89-94
    • /
    • 2017
  • We have examined the issues on the measurement of bifacial photovoltaic(PV) devices that should be considered in order to ensure a measurement accuracy beyond a certain level and the comparability between the bifacial PV devices. Based on the results of various experiments and previous studies, solutions for these measurement issues are suggested. The most significant technical issues in the performance measurement of the bifacial PV devices are 1) elimination of the effect due to the light reflection on the sample holder surface and 2) the measurement of the expected power generation gain in outdoor operation. The effect due to the light reflection on the sample holder surface can be eliminated by using an anti-reflective sample holder. In case of a reflective sample holder, if the bifacial device have a linear characteristic with respect to the irradiance of incident light, it has been confirmed (through some previous studies and additional experiment) that exact measurement results can be obtained by the correction of the measurement data. In addition, it was also confirmed that the expected power generation gain in the outdoor operation can be obtained by three different methods along with the basic concepts of the bifaciality coefficient, the albedo, and the effective front irradiance.