Design of the Detector Head for Single Photon Detection in Breast Cancer Diagnosis and Its Performance Evaluation (유방암진단에서의 단일광자검출을 위한 검출기 전단부의 설계와 성능평가)

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.263-270
    • /
    • 2003
  • Monte Carlo simulation has been peformed to induce optimized parameters of the detector head of gamma camera for the diagnosis of breast cancer and to evaluate it under the diagnosis condition of the breast cancer. For the simulation, we used Tungsten collimator, having a lattice structured array with holes of $3mm{\times}3mm$ and septal thickness of 0.25 mm, which are corresponding to the pixellated photosensor. For driving optimum parameters we used Trade-Offs procedure between the geometric efficiency and the spatial resolution, varying the detector head components. In order to pre-evaluate the performance of the optimized detector head, we assumed diagnosis condition that the breast tumor is located in the middle of phantom with various sizes and its location is 25 mm from the collimator surface, considering background count caused by radiation sources from other organs. It was shown that the performance of the optimized detector head can be degraded according to the breast cancer size and the background count under real diagnosis conditions of breast cancer. Therefore, it is concluded that the spatial resolution, which is used as an indicator to distinguish the various sizes of breast cancer and is dependent on the characteristic of the detector head, appears to be meaningless in early diagnosis of the breast cancer.

Photocurrent Study on the Splitting of the Valence Band and Growth of BaIn2Se4 epilayers by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE)법에 의한 BaIn2Se4 에피레어 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Jeong, Junwoo;Lee, Kijeong;Jeong, Kyunga;Hong, Kwangjoon
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.134-141
    • /
    • 2014
  • A stoichiometric mixture of evaporating materials for $BaIn_2Se_4$ epilayers was prepared from horizontal electric furnace. To obtain the single crystal thin films, $BaIn_2Se_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperatures were $620^{\circ}C$ and $400^{\circ}C$, respectively. The crystalline structure of the epilayers was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $BaIn_2Se_4$ epilayers measured from Hall effect by van der Pauw method are $8.94{\times}10^{17}cm^{-3}$ and 343 $cm^2/vs$ at 293 K, respectively. The temperature dependence of the energy band gap of the $BaIn_2Se_4$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)$=2.6261 eV-$(4.9825{\times}10^{-3}eV/K)T^2/(T+558 K)$. The crystal field and the spin-orbit splitting energies for the valence band of the $BaIn_2Se_4$ have been estimated to be 116 meV and 175.9 meV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_5$ states of the valence band of the $BaIn_2Se_4/GaAs$ epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_1-$, $B_1$-exciton for n = 1 and $C_{21}$-exciton peaks for n=21.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

Optimization of Light Guide Thickness for Optimal Flood Image Acquisition of a 14 × 14 Scintillation Pixel Array (14 × 14 섬광 픽셀 배열의 최적의 평면 영상 획득을 위한 광가이드 두께 최적화)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.365-371
    • /
    • 2022
  • In order to obtain excellent spatial resolution in the PET detector, when the detector module is designed using very small scintillation pixels, overlap occurs at the edges and corners of the scintillation pixel array in the flood image. By using a light guide, the occurrence of overlap can be reduced. In this study, after using a scintillator of 0.8 mm × 0.8 mm × 20 mm to form a 14 × 14 array, 3 mm × 3 mm SiPM pixels are combined with 4 × 4 photosensor to reduce the occurrence of overlap. The optimal thickness of the light guide used for this purpose was derived. Quantitative evaluation was performed based on scintillation pixel images of edges and corners where overlap occurs mainly in the acquired flood image. Quantitative evaluation was calculated through the interval and full width at half maximum between scintillation pixel images, and when a light guide with a thickness of 2 mm was used, the best image was obtained with a k value of 2.60. In addition, as a result of measuring the energy resolution through the energy spectrum, the light guide with a thickness of 2 mm showed the best result at 28.5%. If a 2 mm light guide is used, it is considered that the best flood image and energy resolution with minimal overlap can be obtained.

Fabrication of an Oxide-based Optical Sensor on a Stretchable Substrate (스트레처블 기판상에 산화물 기반의 광센서 제작)

  • Moojin Kim
    • Journal of Industrial Convergence
    • /
    • v.20 no.12
    • /
    • pp.79-85
    • /
    • 2022
  • Recently, a smartphone manufactured on a flexible substrate has been released as an electronic device, and research on a stretchable electronic device is in progress. In this paper, a silicon-based stretchable material is made and used as a substrate to implement and evaluate an optical sensor device using oxide semiconductor. To this end, a substrate that stretches well at room temperature was made using a silicone-based solution rubber, and the elongation of 350% of the material was confirmed, and optical properties such as reflectivity, transmittance, and absorbance were measured. Next, since the surface of these materials is hydrophobic, oxygen-based plasma surface treatment was performed to clean the surface and change the surface to hydrophilicity. After depositing an AZO-based oxide film with vacuum equipment, an Ag electrode was formed using a cotton swab or a metal mast to complete the photosensor. The optoelectronic device analyzed the change in current according to the voltage when light was irradiated and when it was not, and the photocurrent caused by light was observed. In addition, the effect of the optical sensor according to the folding was additionally tested using a bending machine. In the future, we plan to intensively study folding (bending) and stretching optical devices by forming stretchable semiconductor materials and electrodes on stretchable substrates.

Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide (광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.671-677
    • /
    • 2023
  • When a scintillator block is constructed using fine scintillator pixels, the scintillator block located at the edge of the scintillator block results in overlapping images. To solve this problem, a light guide was inserted between the scintillator block and the photosensor, and images of all scintillation pixels were separated and acquired. However, loss of light may occur through the light guide, which eventually affects the quality of the image due to a decrease in energy resolution. Therefore, in this study, a detector was designed that can separate scintilltion pixels better by using a reflector on the side of the light guide and can secre excellent energy resolution by minimizing light loss. For comparative evaluation with previous studies, flood images were obtained through DETECT2000 capable of light simulation, and the degree of separation and light collection rate were evaluated. When a reflector was used on the side of the light guide, all materials showed excellent separation regardless of the material of the light guide, which showed better separation results than previous studies. In addition, the light collection rate was more that five times better when the reflector was applied than when it wa not. If this detector is applied to a small animal positron emission tomography, it will be possilbe to secre excellent image quality through excellent spatial resolution and energy resolution.