• 제목/요약/키워드: Photopolymerization resin

검색결과 23건 처리시간 0.027초

광중합의 시작, 어떤 광조사기를 어떻게 사용해야할까? (Clinical considerations in the use of dental light curing unit)

  • 이창하
    • 대한치과의사협회지
    • /
    • 제57권3호
    • /
    • pp.175-184
    • /
    • 2019
  • Increasing the aesthetic needs of patients and decreasing the use of amalgam had led to increased demand for dental resin composite. Thereby, light curing unit (LCU) has become an essential equipment in dental clinic. To ensure long-term prognosis of photopolymerized materials, LCU should have a uniform and consistent radiant output and an emission spectrum that includes the active wavelength range of photoinitiators. In addition, when the correct use and thorough maintenance and repair of LCU are performed, the higher success rate of restoration using photopolymerization materials will be achieved.

  • PDF

Fabrication and characterization of photocurable inorganic-organic hybrid materials using organically modified colloidal-silica nanoparticles and acryl resin

  • Kang, Dong-Jun;Han, Dong-Hee;Kang, Young-Taec;Kang, Dong-Pil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.422-422
    • /
    • 2009
  • Photocurable inorganic-organic hybrid materials were prepared from colloidal-silica nanoparticles synthesized through the solgel process and using acryl resin. The synthesized colloidal-silica nanoparticles had uniform diameters of around 20 nm, and they were organically modified, using methyl and methacryl functional silanes, for efficient hybridization with acryl resin. The organically modified and stabilized colloidal-silica nanoparticles could be homogeneously hybridized with aeryl resin without phase separation. The successfully fabricated hybrid materials exhibit efficient photocurability and simple film formation due to the photopolymerization of the organically modified colloidal-silica nanoparticles and acryl resin upon UV exposure. The fabricated hybrid films exhibit an excellent optical transmission of above 90% in the visible region as well as an enhanced surface smoothness of around 1 nm RMS roughness. In addition, the hybrid films exhibit improved thermal and mechanical characteristics, much better than those of acryl resin. More importantly, these photocurable hybrid materials fabricated through the synergistic combination of colloidal-silica nanoparticles with acryl resin are candidates for optical and electrical applications.

  • PDF

Preparation and Characterization of Antibacterial Dental Resin Cement Material

  • Kim, Duck-Hyun;Jung, Hwi-Su;Kim, Sun-Hun;Sung, A-Young
    • 대한화학회지
    • /
    • 제62권2호
    • /
    • pp.93-98
    • /
    • 2018
  • Bis-GMA, TEGDMA, and camphorquinone were used as the main material, cross-linking agent, and photoinitiator, respectively. In addition, 2-isocyanatoethyl methacrylate was used as an additive for high strength, while the 3-hydroxypyridine was used as an additive for antibacterial activity. Photopolymerization was also carried out at a 440-480 nm wavelength and at about $1000mW/cm^2$ intensity for about 40 seconds. The breaking strength measurement of the samples showed that the breaking strength increased along with increasing the addition ratio of IEM, while it took less time until the polymerization was complete, thereby suggesting that the degree of polymerization has the tendency to increase. And also, compared to the size of the clear zone formed by ampicillin, the 3-hydroxypyridine group exhibited antimicrobial activity induced by ampicillin. The results of this study suggest that the use of 2-isocyanatoethyl methacrylate as an additive for high strength and 3-hydroxypyridine as an additive for improved antibacterial activity would improve the usability of the fabricated polymer as a dental resin cement material with high functionality.

광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가 (Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

The effect of 4,4'-bis(N,N-diethylamino)benzophenone on the degree of conversion in liquid photopolymer for dental 3D printing

  • Lee, Du-Hyeong;Mai, Hang Nga;Yang, Jin-Chul;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.386-391
    • /
    • 2015
  • PURPOSE. The purpose of this preliminary study was to investigate the effects of adding 4,4'-bis(N,N-diethylamino) benzophenone (DEABP) as a co-initiator to a binary photoinitiating system (camphorquinone-amine) to analyze on the degree of conversion (DC) of a light-cured resin for dental 3D printing. MATERIALS AND METHODS. Cylindrical specimens (N=60, n=30 per group, ${\phi}5mm{\times}1mm$) were fabricated using bisphenol A glycerolate dimethacrylate (BisGMA) both with and without DEABP. The freshly mixed resins were exposed to light in a custom-made closed chamber with nine light-emitting diode lamps (wavelength: 405 nm; power: $840mW/cm^2$) for polymerization at each incidence of light-irradiation at 10, 30, 60, 180, and 300 seconds, while five specimens at a time were evaluated at each given irradiation point. Fourier-transform infrared (FTIR) spectroscopy was used to measure the DC values of the resins. Two-way analysis of variance and the Duncan post hoc test were used to analyze statistically significant differences between the groups and given times (${\alpha}$=.05). RESULTS. In the DEABP-containing resin, the DC values were significantly higher at all points in time (P<.001), and also the initial polymerization velocity was faster than in the DEABP-free resin. CONCLUSION. The addition of DEABP significantly enhanced the DC values and, thus, could potentially become an efficient photoinitiator when combined with a camphorquinone-amine system and may be utilized as a more advanced photopolymerization system for dental 3D printing.

A Surface Treatment Technique for Interim Crown Fabricated by Three-Dimensional Printing with Digital Light-Processing Technology

  • Son, Keunbada;Lee, Jaesik;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.79-89
    • /
    • 2021
  • Purpose: The technique introduced in this study describes a technique for surface treatment that applies a photocuring resin to the surface of an interim crown fabricated by three-dimensional (3D) printing without a conventional polishing method. The purpose of this study was to evaluate marginal and internal fit and the intaglio surface trueness of interim crowns after surface treatment of 3D-printed crowns for clinical application. Materials and Methods: An interim crown was fabricated using a 3D printer with digital light-processing technology, and the surface support was removed. After the posttreatment process, the resin was thinly applied to the surface of the interim crown and polymerized to solve the esthetic problem of the surface without the conventional polishing process. In addition, the marginal and internal fits were measured to verify the clinical use of this technique, and the trueness was evaluated to confirm the deformation of the inner surface according to the technical application of the outer surface of the interim crown. The difference before and after the evaluation by a statistical method was verified using an independent t-test (α=0.05). Result: There was no significant difference in the marginal and internal fit before and after the application of this technique (P>0.05). There was no significant difference in intaglio surface trueness before and after the application of this technique (P=0.963). Conclusion: There was no change in the marginal and internal fit or in intaglio surface trueness of the interim crowns to which this technology was applied. This surface treatment technique is a more convenient method for interim crowns fabricated using 3D-printing technology without the conventional polishing process.

유동성 레진 수복술에서 접착제 중합 여부에 따른 미세누출과 전단결합강도에 관한 연구 (THE EFFECTS OF PHOTOPOLYMERIZATION OF ADHESIVE ON SHEAR BOND STRENGTH AND MICROLEAKAGE OF FLOWABLE RESIN RESTORATION)

  • 박용규;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.398-407
    • /
    • 2007
  • 본 연구는 소아 환자의 유동성 복합 레진 수복 시 접착제의 사용 및 중합 여부 그리고 접착제 종류에 따른 수복물 변연의 미세누출과 전단결합강도를 비교함으로써 치료 시간의 단축 가능성을 타진해보고자 시행하였다. 미세누출을 평가하기 위해 우식이 없거나 법랑질에 제한된 우식이 있는 상, 하악 소구치 84개, 전단결합강도 평가를 위해 협설면에 우식이나 결손부가 없는 대구치 70개를 각각 준비하여 사용하였다. 접착 시스템의 종류에 따라 총 7군을 설정하여 I군과 II군은 Single $Bond^{TM}$, III군과 IV군은 AQ Bond $Plus^{TM}$, Ⅴ군과 Ⅵ군은 Prompt L-$Pop^{TM}$ 그리고 접착 시스템을 사용하지 않고 레진을 충전하는 VII군을 대조군으로 설정하였다. 미세누출과 전단결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. 미세누출 평가 결과 Single $Bond^{TM}$를 사용한 I군과 II군이 다른 군에 비하여 낮은 염료 침투를 나타냈다. I군과 II군 사이의 염료 침투 양상은 유사하게 나타났다. 2. 전단결합측정결과 I군과 II군이 다른 군에 비하여 높은 수치를 나타냈으며 통계적 유의차를 보였다(p<0.05). I군과 II군 사이에는 유의차가 없었다(p>0.05). 3. I군과 II군, III군과 IV군, V군과 VI군 사이에는 통계적 유의차가 없었다(p>0.05). 4. VII군은 I, II군과 V, VI군에 비하여 통계적 유의차가 있게 낮은 전단 결합 강도를 보였으며(p<0.05) III, IV군과는 보다 낮은 수치를 보였으나 통계학적 유의차는 없었다(p>0.05).

  • PDF

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

  • Lee, Jung-Jin;Kang, Cheol-Kyun;Oh, Ju-Won;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE. This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS. Sixty specimens were cut in $15{\times}2.75mm$ discs using zirconia. After air blasting of $50{\mu}m$ alumina, samples were prepared by tribochemical silica coating with $Rocatec^{TM}$ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+$Calibra^{(R)}$, (2) Monobond S+$Multilink^{(R)}$ N and (3) ESPN sil+$RelyX^{TM}$ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS. In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION. In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.

액정-UV경화 이크릴레이트 수지 복합재료의 구조와 물성에 관한 연구 (A Study on Structures and Properties of Liquid Crystal-UV Curable Resin Composite Materials)

  • 김종원
    • 한국인쇄학회지
    • /
    • 제18권1호
    • /
    • pp.59-69
    • /
    • 2000
  • The characteristics of liquid crystal polymer composite(LCPC) films are possessed of large-area and flexible display, polarizer free, high contrast, wide angle of visual filed and high responsiveness. It is well known that the LCPC films consisting of a continuous LC phase embeded in a three-dimentional network of polymer matrix are formed by photopolymerization-induced phase separation. In this study, we have investigated the point that both liquid crystals and polymer having different properties have to coexiste as composed films. The purpose of this study has been the development of new application with liquid crystals and UV-curable monomers. In the results abtained on the miscibility of nematic liquid crystal and UV-curable resins, difunctional monomer HX-620 turned out to shows the best. From the results abtained on structures, electro-optical properties and dynamic visocoelasticity for LCPC films, the best mixing ratio of monomer to LC mixture were 3/7(photoinitiator; 4wt%) by weight, and this ratio has been provided the most thermal stability for LCPC films. In the results abtained on structure and discoloration properties of LCPC films, it has been demonstrated that consiste of a 8:2 mixture of chiral nematic liquid crystal and HX-620 has the greatest domain and it was the best discoloration.

  • PDF

도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교 (Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR)

  • 유지성;김지환;김선재;이용근;심준성
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.416-423
    • /
    • 2009
  • 연구목적: 이번 연구의 목적은 PLV 수복물의 접착 시 사용되는 광중합형 레진 시멘트의 중합도를 Fronrier transform infrared spectroscope로 측정하여 도재의 두께, 광원 및 광조사 시간에 따른 중합도의 차이를 비교하기 위함이다. 연구재료 및 방법: 대조군으로는 1.0 mm의 투명한 slide glass를 사용하였고, 도재 시편은 IPS Empress Esthetic shade ETC1을 선택하여 0.5, 1.0, 1.5 mm의 두께로 제작하였다. 레진 시멘트는 광중합형 레진 시멘트인 Rely $X^{TM}$ Veneer Shade A3를 사용하였다. 광원으로는 Quartz Tungsten Halogen (QTH), Light Emitting Diode (LED), Plasma arc curing (PAC) 광중합기를 사용하였다. 레진 시멘트의 중합도는 FT-IR과 OMNIC 프로그램을 이용하여 측정하였다. 통계분석은 one-way ANOVA와 Tukey HSD를 이용하였다 ($\alpha$=0.05). 결과: 대조군에서 QTH와 LED로 광중합을 시행하였을 때 PAC로 광조사를 시행한 경우보다 중합도가 높았다. QTH와 LED로 광조사를 시행한 경우, 대조군과 0.5 mm, 1.0 mm, 1.5 mm의 도재 두께에서 유의차를 보이지 않았다. 반면, PAC로 광조사를 시행한 결과, 도재의 두께가 1.5 mm인 실험군의 중합도가 대조군과 0.5 mm에서 보다 통계적으로 유의하게 낮은 결과를 보인다 (P<.05). 두께가 1.0 mm의 도재와 LED 광중합기로 광조사하여 중합도를 비교한 결과, 20초간 광조사를 시행하였을 때와 비교하여 80초와 160초간 광조사를 시행한 경우 통계적으로 유의하게 중합도의 평균값이 높았다 (P<.05). 결론: 이번 연구의 한계 내에서, 도재의 두께가 0.5-1.5 mm 이내의 PLV 접착 시, PAC 중합기의 사용은 고려되지 않으며, QTH나 LED로 40초 이상 중합한다면 광중합형 레진 시멘트를 사용할 수 있다. 또한, 광중합형 레진 시멘트를 LED로 중합시킬 경우, 광조사 시간의 증가가 중합도의 증가와 비례하지 않으며, 일정시간 이상의 광조사가 중합도에 큰 영향을 끼치지 않는다.