• 제목/요약/키워드: Photon counting

검색결과 90건 처리시간 0.018초

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

용액내 단분자의 형광소멸시간 계측 (Measurement of fluorecence decay times of single molecules in solution)

  • 고동섭
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.1-4
    • /
    • 1999
  • 공초점 현미경 시스템을 사용하여 반복률이 17MHz이며, 중심파장이 638nm인 극초단 펄스 다이오드 레이저에 의해서 여기된 단분자의 형광폭발신호를 게측하였다. 에칠렌글리콜 용액에 있는 적색 색소 분자(JA22)를 시료로 사용하였다. 시상관 단광자 계수기응 사용하여 단분자들의 현광소멸곡선을 수집하였으며, maximum likelihood estimator로 그것들을 분석하였다. 색소 분자당 40개 이상의 광자수를 가지고 분석하였을 때, 21%의 오차 확률로 형광소멸시간을 계측하는 것이 가능하였다.

  • PDF

광자쌍을 이용한 광검출기의 양자효율 절대측정 (Absolute Measurement of the Quantum Efficiency of Photodetectors Using Correlated Photon Pairs)

  • 안경진
    • 한국광학회지
    • /
    • 제4권4호
    • /
    • pp.452-456
    • /
    • 1993
  • 자발적매개하향변환과정에서 발생되는 광자쌍을 동시계수하여 광전자증배관의 양자효율을 측정하였다. 표준광원이나 표준광원이나 표준복사계를 필요로하지 않는 이 방법으로 560nm에서 850nm 까지의 파장영역에 대하여 3%의 오차로 양자효율을 측정하였으며, 633 nm에서의 측정치는 교정된 레이저출력계와의 비교에 의하여 얻어진 값과 측정오차 내에서 일치하였다.

  • PDF

시간 상관 단일 광자 계수법에 의한 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관한 연구 (Study for energy transfer from Rhodamime 6G to Rhodamine B using time correlated single photon counting method)

  • 엄효순
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.69-73
    • /
    • 1991
  • 모드 동기된 아르곤 이온 레이저를 여기광원으로 사용한 시간상관 단일 광자 계수장치를 이용하여 에탄올 용액 내에서 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관하여 연구하였다. 측정된 형광 소멸 곡선은 본 실험실에서 개발한 full-fit program으로 deconvolution 하여 reduced concentration 과 critical transfer distance를 구했다. donor 의 농도가 acceptor의 농도보다 작을 경우에는 Foster 모델이 클 경우에는 Huber 모델이 잘 맞음을 확인하였다.

  • PDF

Time-resolved UV Fluorescence Spectroscopy of Aorta and its Related Chromophores, Collagen and Elastin, Using 320 nm Excitaion

  • Park, Young D.
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권3호
    • /
    • pp.249-256
    • /
    • 1994
  • Fluorescence time decay of human aorta has been measured at 380, 440, 480 nm using 320 nm excitation and time-correlated single photon counting technique. Fluorescence decay was found to be nonexponential at all emission frequencies. The normal and diseased sample showed significantly different fluorescence behaviors at 380 nm while this time decay difference was decreased in the fluorescence at 440 and 480 nms. The decay data were multiexponential and were analyzed with two exponential decay constants. The fluorescence decays were compared with and analyzed in terms of collagen and elastin.

Development of a Multi-Channel Photoelectric Photometer Using Optical Fiber

  • Lee, W.B.;Kim, H.I.;E.C.Sung;Moon, I.K.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1992년도 한국우주과학회보 제1권1호
    • /
    • pp.231-238
    • /
    • 1992
  • We have developed a proto-type four-channel photoelectric photometer and control software for the 61-cm reflector of the Sobaeksan Astronomy Observatory. The photometer consists of five main units which has a manipulator, a set of four-opticsassemblies, a light detection units, Pulse counting electronics and a host computer. The software to control the chopper, filter wheel and photon counter has also been developed..

  • PDF

액정성 고분자 블렌드의 편발광 (Polarized Light Emission of Liquid Crystalline Polymer Blends)

  • 김영철;조현남;김동영;홍재민;송남웅
    • 폴리머
    • /
    • 제24권2호
    • /
    • pp.211-219
    • /
    • 2000
  • 액정성을 가지는 플로렌계 발광고분자에 비버정성 플로렌계 발광고분자를 첨가한 블렌드를 제조하여 에너지전달 효과와 흡광 및 발광 이방성에 대하여 고찰하였다. 비액정성 고분자를 액정성 고분자에 0.5wt% 첨가하고 360nm로 여기한 결과, 420nm에서 관찰되었던 액정성 고분자의 발광피크는 거의 사라졌으며 대신 비액정성 고분자에 의한 480nm에서의 새로운 발광피크가 관찰되었다. 블렌드 시료의 480nm 발광은 비액정성 고분자가 2.0wt% 첨가되었을때 가장 강했으며, 발광강도는 블렌딩 이전의 각 고분자보다 13배 증자하였다. 블렌드내의 분자들을 마찰 폴리이미드 기판상에서 가열-냉각시켜 배향시키면 시료의 발광 이방성과 order parameter는 각각 2.0 및 0.25를 나타내었다. 시간 상관 단광자 계수법 (TCSPC)에 의해 고찰한 결과, 마찰 폴리이미드 기판상에서의 배향에 의해 두 발광고분자간의 에너지전달에 필요한 시간은 93 ps만큼 단축되며 에너지전달 효율은 9% 증가함을 알 수 있었다.

  • PDF

진동수가 서로 다른 얽힘상태 광자쌍의 4차 간섭 (The fourth-order interference between entangled state photon pairs with different frequencies)

  • 김헌오;고정훈;김태수
    • 한국광학회지
    • /
    • 제13권4호
    • /
    • pp.308-313
    • /
    • 2002
  • 매개하향변환과정에서 동시에 발생한 서로 다른 진동수의 광자쌍을 이용한 4차 간섭실험에서 비고전적인 맥놀이 효과를 측정하였다. 각진동수가 각각 $\omega1$$\omega2$인 광자쌍을 빔분할기에서 중첩시키고, 빔분할기의 두 출구에 놓인 두 검출기로 동시계수 할 때, 두 광자가 빔분할기에 도달하는 시간 간격에 따라 cos($\omega1$-$\omega2$)의 함수로 동시계수의 변화를 나타내었다. 두 광자의 파장 차이가 41㎚일 때 측정된 맥놀이 진동수 ($\omega1$-$\omega2$)/2$\pi$는 0.29${\times}10^{14}$㎐이었고, 진동수 차이에 해당하는 두 광자의 시간간격은 34.82fs로 측정되었다.

1.5 ㎛ 통신파장대역 진동수 얽힘 광자쌍의 양자간섭 (Quantum Interference Experiments with Frequency Entangled Photon Pairs at 1.5 ㎛ Telecommunication Band)

  • 김헌오;김용수;윤천주;조석범
    • 한국광학회지
    • /
    • 제22권6호
    • /
    • pp.276-282
    • /
    • 2011
  • 펨토초 펄스형 자발적 매개하향변환에서 생성된 1.5 ${\mu}m$ 통신파장대역 광자쌍의 진동수 얽힘상태를 구현하고, 광섬유 기반 Hong-Ou-Mandel 간섭계를 이용하여 양자간섭 실험을 수행하였다. 각진동수 ${\omega}_1$${\omega}_2$에 대응하는 두 광자의 파장은 저밀도 파장분할다중화(coarse wavelength division multiplexing, CWDM) 필터를 이용하여 선택하였고, 간섭계에서 경로차에 따른 두 검출기의 동시계수 측정에서 높은 선명도를 갖는 공간적인 맥놀이 형태의 간섭무늬를 관측하였다.

단일모드 광섬유 집광기를 이용한 Hong-Ou-Mandel 간섭 가시도 향상 (Improvement of Hong-Ou-Mandel Interference Visibility by Using a Single-Mode Optical-Fiber Photon Collector)

  • 한성욱;김헌오;서주연;김명훈
    • 새물리
    • /
    • 제68권12호
    • /
    • pp.1374-1377
    • /
    • 2018
  • 우리는 Hong-Ou-Mandel 간섭 실험에서 95% 간섭가시도를 획득했다. 지난 연구에서 56% 가시도를 획득한 것에 비하면 획기적으로 가시도가 개선되었다. 우리는 제1형 자발적 매개 하향 변환 목적으로 제작된 ${\beta}$-Barium Borate 단결정에 405 nm 단일모드 연속 발진 레이저를 주사하여 만들어진 쌍둥이 광자쌍을 표준적인 Hong-Ou-Mandel 간섭광학계를 거치게 한 후 다이오드 기반 단일광자 계수기와 자체적으로 제작한 동시계수기에 의해 간섭신호를 측정했다. 지난 연구와 이번 연구의 가장 큰 차이점은 광자를 집광하는데 단일모드 광섬유를 사용했다는 점이다. 단일모드 광섬유는 중심부 크기가 매우 작기 때문에 광결정에서 발생하는 여러 서로 다른 모드 광자 사이의 우연한 동시계수를 억제시키는 공간 필터역할을 함으로써 가시도가 개선된 것으로 보인다.