• Title/Summary/Keyword: Photon count

Search Result 51, Processing Time 0.026 seconds

Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation

  • Kim, Minho;Bae, Jae Keon;Hong, Bong Hwan;Kim, Kyeong Min;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.539-545
    • /
    • 2019
  • Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons.

Monitoring on the Foods not Approved for Irradiation in Korea by PSL and TL Detection Method (광자극발광법과 열발광법을 이용한 국내 방사선 조사 허용 외 식품에 대한 실태 조사)

  • Cho, Joon-Il;Lee, Ji-Ae;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • This research was conducted to assess applicability of photostimulated luminescence (PSL) and Thermoluminescence (TL) methods for investigation of infant and young children products, nut, seasoned dried fish, spice, dried fruits, fruit & vegetable, grain and marine products, which are not approved for irradiation in Korea. PSL results show that the photon counts of non-irradiated samples were lower than 700, while those of irradiated samples were higher than 700. In TL measurement, TL ratio of irradiated samples were higher than 0.1 or ones can decrease below 0.1 whereas the temperature range of TL Glow curve was between $150{\sim}250^{\circ}C$. Monitoring result about 8 class of 325 not approved to irradiated foods, photon counts of samples were less than 700, and after re-irradiation TL Ratio ($TL_1/TL_2$) through re-irradiation step at 1 kGy were higher than 0.1 for the all samples. Therefore, these results suggested that PSL and TL measurements were useful detection methods for 8 class food products not approved to irradiation in Korea and all sample (325 cases) were not irradiated when we analysed by PSL and TL methods.

Comparison of Photostimulated Luminescence, Thermoluminescence, and Electron Spin Resonance Spectroscopic Analyses on Dried-spices Irradiated by Gamma Ray and Electron Beam (감마선 및 전자선 조사 처리 건조향신료에 대한 광자극발광, 열발광 및 전자스핀공명의 분광학적 분석 비교)

  • Jeong, Jin-Hwa;Ahn, Jae-Jun;Baek, Ji-Yeong;Kim, Hyo-Young;Kwon, Joong-Ho;Jin, Chang-Hyun;Jeong, Il-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.256-261
    • /
    • 2014
  • This study was conducted to determine the effect of gamma-ray and electron-beam irradiation on dried spices (black pepper, red pepper, parsley, and basil) using the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods. The spices were irradiated at 0, 1, 5, and 10 kGy. All non-irradiated spices had photon counts (PCs) less than 700 PCs. The PCs of three irradiated spices (red pepper, parsley, and basil) were clearly distinguishable from those of non-irradiated ones, exhibiting PSL signals higher than 5000 PCs. However, negative PSL counts (<700 PCs) were obtained for most irradiated black pepper, except those irradiated with 5 kGy gamma rays and 10 kGy electron-beams. TL glow curves of the irradiated spices showed a higher peak at $150-250^{\circ}C$. TL ratios were found to be less than 0.1 for non-irradiated spices and higher than 0.1 for irradiated ones. No ESR signal was observed for any irradiated spice except red pepper, which displayed cellulose-based ESR spectra. Therefore, the results suggest that the PSL, TL, and ESR methods are effective detection techniques for dried spices irradiated with electron beams as well as gamma rays.

Detection of Gamma-irradiated Imported Foods (Perilla seeds, Almonds, and Soybeans) by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석을 통한 수입산 들깨, 아몬드 및 대두의 방사선 조사 여부 판별 특성)

  • Han, In-Jun;Yoon, Young-Min;Choi, Soo-Jeong;Song, Beom-Seok;Kim, Jae-Kyung;Park, Jong-Heum;Lee, Ju-Woon;Kim, Jae-Hun;Kim, Kyu-Heon;Cho, Tae-Yong;Yoon, Hae-Sung;Han, Sang-Bae;Lee, Jung-Eun
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.305-310
    • /
    • 2012
  • This study examined radiation detection properties of imported perilla seeds, almonds, and soybeans. Food samples were irradiated at doses of 0.5, 1, 2, and 4 kGy and analyzed by photo-stimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of PSL showed that photon counts of irradiated perilla seeds and soybeans were $32,959counts{\cdot}60sec^{-1}$ and $7,234counts{\cdot}60sec^{-1}$, respectively, at an irradiation dose of 0.5 kGy, and the photon count of irradiated almonds was $5,581counts{\cdot}60sec^{-1}$ at an irradiation dose of 1 kGy. The results of TL showed that this technique is useful for detecting irradiated samples; the TL ratios ($TL_1/TL_2$) measured for the food samples at an irradiation dose of 0.5 kGy were 0.2301 for perilla seeds, 0.4595 for almonds, and 0.4827 for soy beans. Lastly, results of ESR spectroscopy for only soybeans revealed specific signals derived from free radicals captured in the cellulose. In conclusion, PSL, TL, and ESR methods can be used for the detection of gamma-irradiated soybean samples, whereas gamma-irradiated perilla seeds and almonds can be confirmed by a serial detection with a TL method after PSL.

Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

Design of the Detector Head for Single Photon Detection in Breast Cancer Diagnosis and Its Performance Evaluation (유방암진단에서의 단일광자검출을 위한 검출기 전단부의 설계와 성능평가)

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.263-270
    • /
    • 2003
  • Monte Carlo simulation has been peformed to induce optimized parameters of the detector head of gamma camera for the diagnosis of breast cancer and to evaluate it under the diagnosis condition of the breast cancer. For the simulation, we used Tungsten collimator, having a lattice structured array with holes of $3mm{\times}3mm$ and septal thickness of 0.25 mm, which are corresponding to the pixellated photosensor. For driving optimum parameters we used Trade-Offs procedure between the geometric efficiency and the spatial resolution, varying the detector head components. In order to pre-evaluate the performance of the optimized detector head, we assumed diagnosis condition that the breast tumor is located in the middle of phantom with various sizes and its location is 25 mm from the collimator surface, considering background count caused by radiation sources from other organs. It was shown that the performance of the optimized detector head can be degraded according to the breast cancer size and the background count under real diagnosis conditions of breast cancer. Therefore, it is concluded that the spatial resolution, which is used as an indicator to distinguish the various sizes of breast cancer and is dependent on the characteristic of the detector head, appears to be meaningless in early diagnosis of the breast cancer.

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Normal Control Study of Cerebral Blood Flow by Tc-99m HM-PAO SPECT ($^{99m}TC-HMPAO$ SPECT를 이용한 정상인 국소뇌혈류의 정량적 분석)

  • Moon, Dae-Hyuk;Lee, Bum-Woo;Lee, Kyung-Han;Choi, Yoon-Ho;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Yoon, Byung-Woo;Lee, Nam-Soo;Roh, Jae-Kyu;Myung, Ho-Jin;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.155-163
    • /
    • 1989
  • Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using $^{99m}Tc$ HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiqunatitative indices including 'Right to left ratio'(R/L ratio), 'Regional index'(RI), and 'Region to cerebellum ratio'(R/cbll ratio) were calculated. Mean values of R/L ratios of homotogous regions were ranged from 0.985 to 1.023, and mean ${\pm}2$ s.d. of all regions did not exceed 11% of mean. Significant difference of RIs (mean count per voxel of a ROI/mean count per voxel of total ROIs) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, RIs in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p < 0.05-0.001), but vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to RIs.

  • PDF

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF