• Title/Summary/Keyword: Photo Diode

Search Result 257, Processing Time 0.022 seconds

Fabrication and Characterization of Photo-Sensors for Very Small Scale Image System (초소형 영상시스템을 위한 광센서 제조 및 특성평가)

  • Shin, K.S.;Paek, K.K.;Lee, Y.S.;Lee, Y.H.;Park, J.H.;Ju, B.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.187-190
    • /
    • 2000
  • We fabricated general photo diode, surface etched photo diode and floating gate MOSFET by CMOS process. In a design stage, we expect that surface etched photo diode will be improved as to photo sensitivity. However, because the surface of silicon was damaged in etching process, the surface etched diode had a high dark current as well as low photo current level. Finally, we examined the current-voltage properties for the floating gate MOSFET on n-well and confirmed that the device can be act as an efficient photo-sensor. The floating gate MOSFET was operated in parasitic bipolar transistor mode.

  • PDF

The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy (X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발)

  • Kim, Sung-Chul;Lee, Woo-Chul;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

Measurement of Radiation using Photo Diodes (광소자에 의한 일사량 측정)

  • 이남호;백성호;김기복
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.3
    • /
    • pp.39-45
    • /
    • 2001
  • The purpose of this study is to develop an economic and practical radiation sensor using photo diodes which is useful for estimating ET in greenhouse environment. An electronic circuit was then designed. Out put signal of photo diode is amplified with a LM318 transistor and is displayed in a LCD with value from zero to 255. The output signal was compared with that of a ready-made pyranometer. The behavior of the photo diode radiation sensor was evaluated by increasing number of photo diodes. The sensor became more reliable with increased number of photo diodes. Developed radiometer was tested with calibrated relation between pyranometer radiation and photo diode output. It was showed that the photo diodes radiometer would be applicable for the greenhouse environment.

  • PDF

Development of the 4th Generation CD Optical Pick-up with Small Thickness (4세대 박형 CD 광학 픽업 개발)

  • 최영석;김성근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.38-49
    • /
    • 1998
  • The 3rd generation optical pick-up used popularly in resent years is composed of many optical and electronic components such as laser diode, photo diode, beam splitter, objective lens, grating lens, concave lens, collimator lens etc. Therefore, the design of its optical system and its main base which the said optical and electronic components are set on, is complicated and needs high precision. Its assembly and adjustment in the production line is also difficult. This complication and the demand of high precision get its production cost to be high and its reliability to be low. In this paper, the 4th generation optical pick-up is designed and developed, with the hologram device which laser diode. photo diode, beam splitter. and grating lens are integrated in. This optical pick-up reduces the number of points of adjustment by 3, compared with the 3rd generation optical pick-up of which the number of points of adjustment is 6. This optical pickup also decreases by 4 the number of points of W bonding to have bad influence on environmental reliability, decreases by about 10 the number of parts, and establishes about 20% cost-down of material cost, compared with the 3rd generation optical pick-up.

  • PDF

공작기계 슬라이더 운동오차측정시스템 개발

  • 황상옥;정무영;박희재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.43-46
    • /
    • 1992
  • Measurement of straightness errors (vertical, horizontal),and angular error (roll, pitch, yaw) have been classified as difficult tasks in the machine tool metrology field. In this paper, computer aided measurement techniques are proposed using quadrant type photo pin diode. In the developed system, three photo diodes are mounted on the positioning table to detect the five degrees of movement error simultaneously. Outputs from the photo diode are analyzed in the computer and are displayed graphically.

Process Monitoring in Laser Beam Cutting by Photo Diode (레이저 절단에서 광소자를 이용한 가공공정 모니터링)

  • Chang, Ook-Jin;Kim, Bong-chae;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.12
    • /
    • pp.30-37
    • /
    • 1996
  • On-line process control equipment for CO$_{2}$ laser cutting is not available for industrial applications. The major part of the industrial laser cutting machines are adjusted off-line by highly educated engineers. The quality inspection of the sample is visual and referred to different quality scales. Due to the lack of automation the potential laser users hesitate to implement the cutting method. The first step toward an automation of the process is the development of a process monitoring system and the research is cincentrated on the area of on-line quality monitoring during CO$_{2}$ laser cutting. The method is based on the detection of the emitted light from the cutting front by photo diode. The developed monitoring system consists of the OP Amplifier, A/D convertor, power supply and PC. The signal from the photo diode has been undertaken from Fourier analysis and statistical analysis with real time. The photograph of striation pattern was taken by metallurgical microscope. As a result, it is possible to predict the striation pattern according to the beam traveling speed.

  • PDF

Studies on Fabrication of Diodes and Photo Cell Using BP-Si structure (BP-Si구조를 이용한 다이오드 및 Photo Cell의 제작에 관한 연구)

  • 홍순관;복은경;김철주
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.7
    • /
    • pp.774-779
    • /
    • 1988
  • The homo and hetero-junction diodes were fabricated using BP-Si structure. After removal of Si substrates, schottky diodes were fabricated on the BP bulk. The electrical properties of the diode were examined through current-voltage characteristics curve. The schottky diode with Sb electrode has a cut-in voltage of 0.33V. This value is almost equal to that of the typical schottky diodes. The breakdown voltage of the schottky diode is 30V. When BP was used for photo cell as a window, the conversion efficiency improved from 6.5% to 8.3%, and optical transmissivity of BP invreased in short wavelength region.

  • PDF

Process Monitoring in Laser Beam Cutting by Photo Diode (레이저 절단에서 광소자를 이용한 가공공정 모니터링)

  • 김봉채;장욱진;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.354-359
    • /
    • 1994
  • On-line process control equipment for CO $_{2}$ laser cutting is unavailable for industrial application. The major part of the industrial cutting machines are regulated off-line by highly educated engineers. The quality inspection of the sample is visual and referred to different quality scales. Due to lack of automation potential laser users hesitate to implement the cutting method. The first step toward an automation of the process is development of a process monitoring system and the research is concentrated on the area of on-line quality detection during CO $_{2}$ laser cutting. The method bases on the detection of the emitted light from the cut front by photo diode. the signal from photo diode has been undertaken from Fourier analysis and statistical analysis. As a result, it is possible to estimate striation pattern according to beam travel speed.

  • PDF

Development of Sorting Machine for Photo Diode and Improvement of Sorting Precision by using Machine Vision (광 다이오드 분류장치 및 비젼을 이용한 정밀도 향상)

  • Ryuh B.S.;Park S.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.153-154
    • /
    • 2006
  • Development of sorting machine for photo diode and its control system is addressed. The sorting machine for optical communication device requires high positional precision because the alignment is one of the most important point in the sorting process. This sorting method describes how to detect the target chip's angle and position from the wafer. The machine vision system is used for the feedback control. This sorting machine is implemented by motion controller, machine vision and various solenoid valve and is interfaced with RS-232c, GPIB and PCI communication. This system gets the position accuracy within $1{\mu}m$ with our experiments.

  • PDF

A Fiber Laser Spectrometer Demodulation of Fiber Bragg Grating Sensors for Measurement Linearity Enhancement

  • Kim, Hyunjin;Song, Minho
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.312-316
    • /
    • 2013
  • A novel fiber-optic sensor system is suggested in which fiber Bragg grating sensors are demodulated by a wavelength-sweeping fiber laser source and a spectrometer. The spectrometer consists of a diffraction grating and a 512-pixel photo-diode array. The reflected Bragg wavelength information is transformed into spatial intensity distribution on the photo-diode array. The peak locations linearly correspond to the Bragg wavelengths, regardless of the nonlinearities in the wavelength tuning mechanism of the fiber laser. The high power density of the fiber laser enables obtaining high signal-to-noise ratio outputs. The improved demodulation characteristics were experimentally demonstrated with a fiber Bragg grating sensor array with 5 gratings. The sensor outputs were in much more linear fashion compared with the conventional tunable band-pass filter demodulation. Also it showed advantages in signal processing, due to the high level of photo-diode array signals, over the broadband light source system, especially in measurement of fast varying dynamic physical quantities.