• 제목/요약/키워드: Phase shifted dc-dc full bridge converter

검색결과 42건 처리시간 0.02초

홀드 업 타임 보상회로를 가진 IT 기기용 Front-end PSFB DC/DC 컨버터 (Phase-Shifted Full Bridge(PSFB) DC/DC Converter with a Hold-up Time Compensation Circuit for Information Technology (IT) Devices)

  • 이강현
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.501-506
    • /
    • 2013
  • A hold-up time compensation circuit is proposed to get high efficiency of the front-end phase-shifted full bridge DC/DC converter. The proposed circuit can make the phase-shifted full bridge front-end DC/DC converter built with 0.5 duty ratio so that the conduction loss of the primary side and voltage stress across rectifier in the secondary side are reduced and the higher efficiency can be obtained. Furthermore, the requirement of an output filter significantly can diminish due to the perfect filtered waveform. A 12V/100A prototype has been made and experimental results are given to verify the theoretic analysis and detailed features.

Cascode GaN HEMT를 적용한 위상 천이 dc-dc 컨버터의 구현 및 문제점 분석 (Implementation and Problem Analysis of Phase Shifted dc-dc Full Bridge Converter with GaN HEMT)

  • 주동명;김동식;이병국;김종수
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.558-565
    • /
    • 2015
  • Gallium nitride high-electron mobility transistor (GaN HEMT) is the strongest candidate for replacing Si MOSFET. Comparing the figure of merit (FOM) of GaN with the state-of-the-art super junction Si MOSFET, the FOM is much better because of the wide band gap characteristics and the heterojunction structure. Although GaN HEMT has many benefits for the power conversion system, the performance of the power conversion system with the GaN HEMT is sensitive because of its low threshold voltage ($V_{th}$) and even lower parasitic capacitance. This study examines the characteristics of a phase-shifted full-bridge dc-dc converter with cascode GaN HEMT. The problem of unoptimized dead time is analyzed on the basis of the output capacitance of GaN HEMT. In addition, the printed circuit board (PCB) layout consideration is analyzed to reduce the negative effects of parasitic inductance. A comparison of the experimental results is provided to validate the dead time and PCB layout analysis for a phase-shifted full-bridge dc-dc converter with cascode GaN HEMT.

개선된 Clamp Circuit 적용 ZVZCS FB DC/DC 컨버터 (An Improved ZVZCS PWM FB DC/DC Converter Using the Modified Clamp Circuit)

  • 김은수;조기연;김윤호;이진수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.643-645
    • /
    • 1999
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with the modified energy recovery snubber (ERS) attached at the secondary side of transforemr.

  • PDF

220V, 440V 3상 계통전압 혼용이 가능한 용접 전원장치용 위상천이 풀브리지 컨버터 (Phase-Shifted Full-Bridge Converter for Welding Power Supply Capable of Using 220 V, 440 V 3-Phase Grid Voltages)

  • 윤덕현;이우석;이준영;이일운
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.372-375
    • /
    • 2021
  • A three-leg inverter-type isolated DC-DC Converter that can use 220 and 440 V grid input voltages is introduced. The secondary circuit structure of the proposed topology is center-tap, which is the same as the conventional phase-shifted full-bridge converter. However, the primary circuit structure is composed of a three-leg inverter structure and a transformer, in which two primary windings are connected in series. The proposed circuit structure has a wider input voltage range than the conventional phase-shifted full-bridge converter, and the circulating-current on the primary-side is reduced. In addition, the voltage stress at the secondary rectifier is greatly improved, and high efficiency can be achieved at a high input voltage by removing the snubber circuit added to the conventional converter. Prototype converters with input DC of 311 V, output of 622 V, and 50 V and 6 kW class specifications were designed and manufactured to verify the validity of the proposed topology; the experimental results are presented.

위상이동 제어 방식을 이용한 풀브리지 컨버터의 효율개선에 관한 연구 (A Study on Efficiency Improvement of F-B Converter with Phase-shifted control method)

  • 서재광;김용;백수현;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2685-2687
    • /
    • 1999
  • This paper is concerned on developing DC-DC converter. In contrast to resonant converter, this converter requires no external resonant elements and operates with constant switching frequency. In conventional PWM converter, two MOSFET switches of the converter are simultaneously turned on and turned off. In presented converter, to achieve Zero Voltage Switching, the two legs of the bridge are operated DC-DC converter is phase shifted. Phase shifted Full Bridge ZVS PWM Converter have an effect on the power system. Operation principle and features are illustrated by the experiment results from 50W, 250kHz with MOSFET switch.

  • PDF

ZVS 기법을 사용한 위상제어 PWM FB DC/DC 컨버터 (Phase-shifted PWM FB DC/DC Converter with ZVS Method)

  • 김성철;권순걸;계문호;조기연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.392-394
    • /
    • 1996
  • This paper is to describe how to apply the Phase-shifted Full Bridge 100kHz high frequency soft-switching PWM method to 48[V], 200[A] DC/DC converter. The soft-switching is achieved from light load to full load by using phase-shifted zero voltage switching method with additional capacitors besides the MOSPET's of the right leg even though the leakage inductance of high frequency transformer is designed small. This method can reduce the switching tosses, EMI problems, and increase the effective duty. Also, this paper includes the simulation, analysis, and experiment results of the DC/DC converter unit.

  • PDF

새로운 소프트 스위칭 FB DC-DC 컨버터 (Novel soft switching FB DC-DC converter)

  • 김은수;최해영;조기연;계문호;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.251-255
    • /
    • 1997
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with energy recovery snubber (ERS) attached at the secondary side of transformer. The energy recovery snubber (ERS) adopted in this study is consisted of three fast recovery diode(Ds1, DS2, Ds3), two resonant capacitor (Cs1, Cs2)

  • PDF

Feasibility Study of Tapped Inductor Filter Assisted Soft-Switching PWM DC-DC Power Converter

  • Moisseev S.;Sato S;Hamada S;Wakaoka M
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.231-234
    • /
    • 2003
  • This paper presents a novel high frequency transformer linked full-bridge type soft-switching phase-shift PWM control scheme DC-DC power converter, which can be used as power conditioner fur small-scale fuel cell power generation system. Using full-bridge soft-switching DC-DC converter topology makes possible to use low voltage high performance MOSFETs to achieve high efficiency of the power conditioner. A tapped inductor filter is implemented in the proposed soft-switching converter topology to achieve soft-switching PWM constant high frequency operation for a wide load variation range. to minimize circulating and idling currents without using additional resonant circuit and auxiliary power switching devices. The practical effectiveness of the proposed soft-switching DC-DC converter is verified in laboratory level experiment with 1 kW 100kHz breadboard setup using power MOSFETs. Actual efficiency of 94-96$\%$ is obtained for the wide load range

  • PDF

ESS용 고효율 풀브리지 컨버터 및 인버터 설계 (Design of High-Efficiency Full-Bridge Converter and Inverter for ESS)

  • 정재훈;이창우;최진구
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.685-688
    • /
    • 2015
  • 기존의 컨버터에서 널리 사용되는 위상천이 풀브리지 컨버터(Phase-Shifted Full-Bridge Converter) 경우 입력 전원 변화에 출력 전압의 변동이 있는 경우 듀티 변화에 따른 Freewheeling 구간이 존재하게 되며 효율을 감소시키는 요인이 된다. 본 논문에서는 고효율을 요구하는 ESS 시스템에서 컨버터/인버터의 효율 향상 방안을 제시한다. Freewheeling 구간에서 ZVS(Zero Voltage Switching) 실패문제를 해결하기 위한 듀티 제어 기법을 사용하여 구현하였으며 실험 결과 효율을 향상시켰다.

  • PDF

태양광 모듈 통합 전기 자동차용 Phase Shift Full Bridge Converter (A PV-Module Integrated Phase Shift Full Bridge Converter for EV)

  • 황윤경;남광희
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.425-432
    • /
    • 2020
  • The phase-shifted, full-bridge (PSFB) DC-DC converter is widely used in electric vehicles (EVs) to charge a low-voltage (12 V) battery from a high-voltage battery. A Photovoltaic (PV) module-integrated PSFB converter is proposed for the EV power conversion system. The converter is useful because solar energy can be utilized to extend the driving range. The buck converter circuit is simply realized by adding one switch to the conventional PSFB converter's secondary side. For the inductor and diode, the existing components in the PSFB converter are shared. The proposed converter can charge a low-voltage battery from the PV module with maximum power point tracking. In addition, the two power sources can be used simultaneously, and efficiency is increased by reducing the circulating current, which is a problem for the conventional PSFB converter.