• Title/Summary/Keyword: Phase Detector

Search Result 760, Processing Time 0.03 seconds

Monitoring of 7 mycotoxins in pork (돼지고기에서 7종 mycotoxins 잔류실태 조사)

  • Kim, Yoen-Joo;Kim, Mi-Ran;Choi, Tae-Suk;Kim, Young-Seob;Lee, Ju-Hyoung
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.4
    • /
    • pp.303-309
    • /
    • 2013
  • This study was conducted to determine the content of 7 mycotoxins (aflatoxin $B_1$, $B_2$, $G_1$, $G_2$, $M_1$, ochratoxin A and zearalenone) using LC-MS/MS in pork available on the Korean markets. The analysis was carried out using following conditions; C18 column ($2.1{\times}100mm$, $1.7{\mu}m$), mobile phase composed of $H_2O$ (0.1 mM $NH_4Ac$ 0.01% HCOOH) : Methanol (0.1 mM $NH_4Ac$ 0.01% HCOOH), binary pump at a flow rate of 0.5 mL/min and $2{\mu}L$ of injection volume, MS/MS detector with ESI positive and negative mode. The quantication of mycotoxins was based on matrix-matched calibration curves with a correlation coefficient in excess of 0.99 for the 7 mycotoxins. The dectection limits were ranged 0.74~2.13 ng/g, with mean recoveries between 73.10~97.46% except aflatoxin $B_1$ (61.31%). We also monitored mycotoxin residues in 208 pork samples. The test results, mycotoxins were not found except one sample. Ochratoxin A in one sample of the test samples was detected below the quantification limit.

Action Mechanism of S-23142 on the PPIX Biosynthesis System of Spinacia oleracea L. Chloroplast (엽록체내 Protoporphyrin IX(PPIX) 생합성계에서 S-23142의 작용기구)

  • Kim, T.J.;Kim, J.S.;Cho, K.Y.;Yoshida, S.
    • Korean Journal of Weed Science
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 1994
  • The effects of S-23142{N-(4-chloro-2-fluoro-5-propargyloxyphenyl)-3, 4, 5, 6-tetrahydrophtalimide}, on protoporphyrin IX(PPIX) biosynthesis in Spinacia oleracea L, leaf in vivo and in vitro condition were investigated by reversed-phase HPLC with fluorescence detector. The stroma and the membrane fraction of spinach chloroplast were isolated by osmotic regulation. The conversion of ${\delta}$-aminolevulinic acid(ALA) to PPIX occured more in the stroma than in the membrane fraction. It suggested that the enzymes that catalyse PPIX biosynthesis from ALA were localized in the stroma. Also, the synthesized PPIX content from ALA was completely inhibited by $10^{-8}M$ of S-23412 or $10^{-7}M$ of acifluorfen in the stroma but not in the membrane fractions. Therefore, these results suggested that the target site of S-23142 and acifluorfen may exist in the stroma fraction of spinach chloroplast.

  • PDF

Study on HPLC conditions for chemotaxonomy of Ganoderma species (영지버섯의 화학적 계통분류를 위한 HPLC분석 방법에 관한 연구)

  • Yoon, Dae-Eun;Park, Young-Jin;Kwon, O-Chul;Nam, Jae-Young;Kim, Hong-Il;Yoo, Young-Bok;Kong, Won-Sik;Lee, Chang-Soo
    • Journal of Mushroom
    • /
    • v.11 no.2
    • /
    • pp.107-110
    • /
    • 2013
  • This study was carried out to optimize the conditions for a chemotaxonomic classification of Ganoderma species. The mycelia of Ganoderma species were extracted with 100% MeOH, and the concentrated extracts were further purified and partitioned with column chromatography (HP20) and n-BuOH, respectively. From the result of high-performance liquid chromatography (HPLC), the constituents of the samples were efficiently separated with a Chemco Pak $C_{18}$ column ($250mm{\times}4.6mm$) by linear gradient elution using water and acetonitrile as mobile phase components at a flow rate of 0.8 ml/min and detector wavelength at 210 nm. However, the samples without purification or partition were not detected the characteristic peaks. This profile could be used to classify and identify the various Ganoderma species.

Compressibility of $FeS_{2}$ ($FeS_{2}$의 압축성 연구)

  • Kim, Young-Ho;Hwang, Gil-Chan;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.189-195
    • /
    • 2006
  • Compression work on a pyrite powder has been carried out using energy dispersive X-ray diffraction (EDXRD) with Mao-Bell type diamond anvil cell (DAC) and synchrotron radiation(SR) at room temperature. It has been reported the bulk moduli of pyrite show the large variations depending on the experimental conditions as well as the apparatus used. Thus, two kinds of sample in different pressure transmitting media of both NaCl and MgO powder emerged in alcoholic fluids were subjected to measure their compressibilities. Bulk moduli thus obtained are 138.9 GPa and 198.2 GPa, respectively, and this result contradicts to the anticipated values according to the hydrostaticity conditions of the sample chamber. This might be due to the alcoholic fluids phase transition mainly with the side effects from the difference of both solid state detector (SSD) used and E*d value applied. All experiments were performed at the Beam Line 1B2 of Pohang Light Source (PLS).

Dither-stripping with the differential of dither rate signal for a ring laser gyroscope (링레이저 자이로의 각진동 센서신호 미분에 의한 dither-stripping)

  • Shim, Kyu-Min;Chung, Tae-Ho;Lim, Hoo-Jang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.65-74
    • /
    • 2005
  • It is required for getting the ring laser gyro output purely related to the input rotation to eliminate the output of the modulated angular vibration from the ring laser signal. In this paper we discuss the dither stripping methods of compensating the ring laser signal by converting the rate signal of dither detector from voltage to frequency for a dither type ring laser gyro. We discuss the differential methods for getting rid of the offset of the V-F signal. And we develope the methods of compensating the phase differences between the ring laser signals and the V-F differential signals by using analog integrator and digital time delays. And also, we develope the gain calculation method by comparing the standard deviations of the ring laser signals with V-F differential signals. We implemented these methods and analyzed the effectiveness of these methods by comparing the dither trapping methods.

Design of A Clock-and-Data Recovery Circuit for Detection and Reconstruction of Broadband Multi-rate Optical Signals (다중속도의 광신호 추출 및 클락-데이터 복원회로 설계)

  • Kim, Kang-Wook
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2003
  • Due to explosive increase of internet usage, broadband data transmission using optical fibers is broadly used. In order to decrease distortion during long distance transmission, the optical signal need to be restored, typically, by converting the optical signal into the electrical signal. The optical signal is converted into the electrical signal using a photo-diode, and then a clock-and-recovery (CDR) circuit is used to recover the clock and retime the data. In this study, a clock-and-data recovery circuit has been designed using a standard 1.8 V $0.18\;{\mu}m$ CMOS process. With this CDR circuit, the improved phase detector and charge pump have been utilized. Also, by using a ring oscillator, the CDR circuit can recover clock and data from broadband multi-rate data ranging between 750 Mb/s and 2.85 Gb/s.

Development of Biologically Active Compounds from Edible Plant Sources-XI -Analysis of Phytol Content in Several Varieties of Lactuca sativa L. by gas chromatography- (식용식물자원으로부터 활성물질의 탐색-XI -GC를 이용한 상추(Lactuca sativa L.)의 품종별 Phytol 함량 분석-)

  • Song, Myoung-Chong;Lee, Jin-Hee;Bang, Myun-Ho;Kim, Ji-Young;Chung, Dae-Kyun;Pai, Tong-Kun;Kim, In-Ho;Baek, Nam-In
    • Applied Biological Chemistry
    • /
    • v.47 no.4
    • /
    • pp.426-429
    • /
    • 2004
  • An easy, sensitive and rapid method for the analysis of phytol, a strong ACAT (Acyl-CoA: Cholesterol Acyltransferase) inhibitory diterpenoid, was established. The pre-treatment of sample for GC analysis of phytol includes aq. MeOH extraction, partition of the extracts between EtOAc and water, and filtration of organic phase through Supelclean LC-Si SPE tube. The GC analysis of phytol for a variety of Lactuca sativa was carried out on DB-5 capillary column with flame ionization detector (FID). The consistency in phytol contents according to each variety was not shown. Especially, Jeoktoma, as RS-2 type, showed the highest phytol content.

Simultaneous Analysis of Bioactive Metabolites from Caulis Lonicera japonica by HPLC-DAD-ion trap-MS (HPLC-DAD-ion trap-MS를 이용한 인동 생리활성 물질의 동시분석)

  • Ryu, Sung-Kwang;Won, Tae-Hyung;Kang, Sam-Sik;Shin, Jong-Heon
    • YAKHAK HOEJI
    • /
    • v.54 no.3
    • /
    • pp.157-163
    • /
    • 2010
  • A high-performance liquid chromatography (HPLC) with DAD detector and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of coniferin (1), loganic acid (2), demethylsecologanol (3), sweroside (4) and loganin (5) from caulis Lonicera joponica. The optimal chromatographic conditions were obtained on an ODS column ($5{\mu}m$, $4.6{\times}150mm$) with the column temperature $35^{\circ}C$. The mobile phase was composed of (A) water with 0.1% formic acid and (B) methanol with 0.1% formic acid using a gradient elution, the flow rate was 0.3 ml/min. Detection wavelength was set at 254 nm. All calibration curves showed good linear regression ($r^2$>0.998) within test ranges. The developed method provided satisfactory precision and accuracy with overall intra-day and interday variations of 0.16~3.28% and 0.14~1.99%, respectively, and the overall recoveries of 99.39~105.89% for the five compounds analyzed. The verified method was successfully applied to quantitative determination of the two types (phenolic compounds and iridoids) of bioactive compounds in 24 commercial caulis L. japonica samples from different markets in Korea and China. The analytical results demonstrated that the contents of the five analytes vary significantly with sources.

Simultaneous Analysis of three Marker Components in Hwangryunhaedok-tang by HPLC-DAD (황련해독탕 중 3종 생리활성 물질의 HPLC-DAD 동시 정량분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • YAKHAK HOEJI
    • /
    • v.55 no.1
    • /
    • pp.64-68
    • /
    • 2011
  • In this study, a high performance liquid chromatography-diode array detector method was established, for simultaneous determination of three compounds, berberine, palmatine and geniposide in Hwangryunhaedok-tang, To develop and validate method, $C_{18}$ column (5 ${\mu}M$, 4.6 mm${\times}$250 mm) was used with gradient mobile phase, water containing 0.1% trifluoroacetic acid (TFA) and MeOH at the column temperature of $30^{\circ}C$. UV wavelength was set at 230 and 280 nm. Validation of the chromatography method was evaluated by linearity, precision and accuracy test. Calibration curve of standard components showed good linearity ($R^2$ > 0.9999). The limits of detection (LOD) and limits of quantification (LOQ) varied from 0.05 to 0.17 ${\mu}g/ml$ and 0.15 to 0.53 ${\mu}g/ml$, respectively. The relative standard deviations (RSDs) data of intra-day and inter-day test were in less than 2.99% and 1.90%, respectively. The results of the accuracy test were in the range of 98.36 to 102.52% with RSDs values 0.32 to 1.98%. The results of validation indicated that this method was a very accurate and sensitive assay.

Design of Thomson Scattering System Using VPH Grating for Plasma Processing

  • Joa, Sang-Beom;Ko, Min-Guk;Kang, In-Je;Yang, Jong-Keun;Yu, Yong-Hun;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.525-525
    • /
    • 2013
  • Low temperature plasma diagnosis is one of the big issues in laboratory scale or processing industry. One of the most powerful techniques of plasma diagnostics is the use of the scattering of electromagnetic radiation from the plasma. Electron temperature and density are important parameters for understanding the information of plasmas in the plasma processing industry. Laser scattering experiments on plasma can provide a substantial amount of information about plasma parameters such as the electron density ne, the electron temperature Te, and the neutral density nn and temperature Tn. Thomson scattering spectroscopy is used several method, in accordance with detector type. Commonly, Thomson scattering is used several notch filter to separate expanded wavelength. Since using a spectrometer with surface relief grating or notch filter, the system of the measurement will be complicated and bigger. In this study, using VPHG (Volume Phase Holographic Grating) in order to install the simple and cheap system. VPHG has the advantage of the system installation, because it can be Transmission Type. The diffraction efficiency and dispersion angle of VPHG is higher than the surface relief grating relatively. For a wavelength and bandwidth selection, Using a slit or mask to select a rejection wavelength instead of notch filter.

  • PDF