• Title/Summary/Keyword: Phase Adjustment

Search Result 210, Processing Time 0.036 seconds

Robust Deadbeat Current Control Method for Three-Phase Voltage-Source Active Power Filter

  • Nishida, Katsumi;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.102-111
    • /
    • 2004
  • This paper is concerned with a deadbeat current control implementation of shunt-type three-phase active power filter (APF). Although the one-dimensional deadbeat control method can attain time-optimal response of APF compensating current, one sampling period is actually required fur its settling time. This delay is a serious drawback for this control technique. To cancel such a delay and one more delay caused by DSP execution time, the desired APF compensating current has to be predicted two sampling periods ahead. Therefore an adaptive predictor is adopted for the purpose of both predicting the control error of two sampling periods ahead and bringing the robustness to the deadbeat current control system. By adding the adaptive predictor output as an adjustment term to the reference value of half a source voltage period before, settling time is made short in a transient state. On the other hand, in a steady state, THD (total harmonic distortion) of the utility grid side AC source current can be reduced as much as possible, compared to the case that ideal identification of controlled system could be made.

Request Two-Phase Locking Method for Series Sequence Re-adjustment of Concurrency Control in Multi-Level Secure DBMS (다단계 보안 데이터베이스 시스템에서 병행수행 제어의 직렬화 순서를 재조정하기 위한 요청 2단계 로킹기법)

  • Lee, Seungsoo;Cho, Jinsung;Jeong, Byungsoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.105-108
    • /
    • 2004
  • 다단계 보안데이터베이스 시스템에서 기본적인 병행수행 제어 기법들은 비밀채널과 교착상태등과 같은 문제들이 발생하였다. 이에 직렬화 순서를 동적으로 재조정함으로서 해결하려는 방안이 있었지만, 알고리즘의 복잡성으로 인해 오버 헤드와 많은 수행시간이 필요하게 되었고, 이에 따라 많은 양의 시스템 자원과 높은 사양의 시스템을 요구하게 되었다. 또한 이러한 방법은 다중 버전을 사용함으로서 추가적인 관리비용이 높게 되었고, 각각의 트랜잭션이 지연 및 재수행이란 불필요한 과정을 반복하게 되었다. 따라서 본 논문에서는 제안한 알고리즘은 데이터베이스의 용도에 맞게 직렬화 순서를 보장하여 스케줄을 관리하는 요청 2단계 로킹기법(Request Two-phase Locking)으로서 이는 2단계 로킹기법의 기본원리에 요청로크를 사용함으로 보다 효율적으로 병행제어를 할 수 있다. 여기서 요청로크는 각각의 트랜잭션 스케줄에 로크획득 및 해제를 병행수행제어의 필요에 따라 유동적으로 할 수 있으며, 읽기로크, 쓰기로크, 요청로크라는 3가지 로킹모드를 통해 대처방안을 마련함으로서, 충돌을 방지하며, 충돌연산의 특성에 따라 직렬화 순서를 동적으로 조정함으로 블록킹을 막는 병행제어를 응용하여 병렬성을 유지한다.

  • PDF

Stopper equipped with a Low Vibration Floating Slab System Design (스토퍼가 장착된 저진동 플로팅 슬래브 시스템 설계)

  • Park, Sung-Jae;Ma, Chang-Nam;Park, Myung-Gyun;Lee, Du-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.753-756
    • /
    • 2011
  • Recently the construction of railway sections passing the central area of cities and stations under railway lines are increasing, and then it is urgently required to take the countermeasures against the railway vibration and the second-phase noise radiated from it. The most efficient countermeasure, out of technologies developed up to now, is the floating slab track which is the track system isolated from the sub-structure by springs. In other countries, the source technologies for anti-vibration design and vibration isolator - one of key components - have been developed and many installation experiences have been accumulated. However, in Korea, since the system design technology and technologies for key components are not yet developed, the foreign system are being introduced without any adjustment, and the key component, vibration isolator, depends on imports. In this study, analysis on floating slab system installed rubber mat and stopper is carried for the examination on the safety of floating slab system.

  • PDF

Development of the DNC System for SFC/POP (SFC/POP 연계형 DNC 시스템 구현)

  • Choi, Jung-Hee;Kim, Jae-Gyun;Lee, Dong-Hyun;Choi, In-Jib
    • IE interfaces
    • /
    • v.12 no.3
    • /
    • pp.374-381
    • /
    • 1999
  • In this paper, we propose an architecture of the DNC system for Shop Floor Control/Point of Production(SFC/POP). The DNC system to be presented this paper retrieves line-up sheets which include the drawing information, making a index database for line-up sheets, NC programs and tool adjustment data. And it is interface with a raw material, jig and tool information. Also, the DNC system transmits operation information to real workers rapidly, and supports realtime monitoring by collecting the state information of machines directly. In the analysis and design phases, this paper models realtime events using the state transition diagrams. In the implementation phase, we use the ORACLE DBMS(Database Management System) as the DBMS and Developer 2000 and Microsoft Visual C++ 5.0 as the programming tools.

  • PDF

A Technique for Accurate Measurement of Power System Frequency (전력설비의 정밀주파수진단을 위한 기법)

  • Nam, S.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Study on Securing the Funds Liquidity of Construction Phase (건설공사단계의 자금 유동성 확보 방안에 관한 연구)

  • Je, Yeong-Deuk;Lee, Sang-Beom;Song, Ho-San
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.69-70
    • /
    • 2011
  • During the financial crisis in the late 1990s, we witnessed the large corporations failing at one moment. It is clear that the debt-dependant size augmentation and duplicate investment, and the failure in fund liquidity adjustment were the greatest causes rather than the long-term strategic advantage. Such fact, however, has led to the introduction of advanced financial techniques and security/management of fund liquidity. In order to propose a method to secure fund liquidity at the construction level, this study considers the documentational/precedent studies on project financing among fund procurement methods. And the fund liquidity status at construction level is investigated domestically/internationally to analyze the fund flow. Finally, the actual data is used to analyze progress rate and sales rate to end with the proposal of the method to secure fund liquidity in the progression of this study.

  • PDF

A Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

An Iterative Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 반복기법)

  • Nam, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.92-95
    • /
    • 2003
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints. it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

Optimal Guidance and Nonlinear Tracking Control for a Lunar Lander

  • Hwang, Myung-Shin;Kim, Jin-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.167.2-167
    • /
    • 2001
  • This paper presents guidance and control laws which guarantee a minimum fuel consumption and have obustness against various disturbances during a terminal-landing phase on the lunar surface. The nonlinear robust tracking control system is designed to track the reference profiles, which are expressed by exponential functions. An adjustment law in the tracking controller is given in the form of the differential equations with respect to the controller´s variable gains. Computer simulations are performed to examine the tracking accuracy, the robustness in a thrust failure mode, and the vertical soft landing at a pre-assigned point on the lunar surface. The results of numerical simulation show the effectiveness of the present control law.

  • PDF

A Stable Model Reference Adaptive Control with a Generalized Adaptive Law (일반화된 적응법칙을 사용한 안정한 기준모델 적응제어)

  • 이호진;최계근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.8
    • /
    • pp.1167-1177
    • /
    • 1989
  • In this paper, a generalized adaptive law is proposed which uses a rational function type operator for parameter adjustment. To satisfy the passivity condition of the adaptation block, we introduce a constant feedback gain into the adaptation block. This adaptation scheme is applied to the model reference adaptive control of a continuous-time, linear time-invariant, minimum-phase system whose relative degree is 1. We prove the asymptotic stability of the output error of this adaptive system by hyperstability method. It is shown that by digital computer simulations this law can give a better output error transient response in some cases than the conventional gradient adaptive law. And the output error responses for the several types of the proposed adaptation law are examined in the presence of a kind of unmodeled dynamics.

  • PDF