중대산업사고 예방을 위한 종합위험관리체제(IRMS) 구축에 관한 연구 (Research on the Prevention of Major Industrial Accident By Integrated Risk Management System)

  • 권혁면;성대현;김재현;임대식;김기영;편무욱;문일;고재욱;이영순;윤인섭
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.88-93
    • /
    • 2003
  • The Process Safety Management (PSM) by the Law of Industry, Safety and Health has been performed for preventing major accidents of chemical plants since 1996. In terms of preventing chemical accidents more precisely, it is essential to develop a tool for quantitative risk assessment. For this, KOSHA (Korea Occupational Safety and Health Agency) developed an Integrated Risk Management System (IRMS). The system is designed to assimilate data on chemical plant hazards from external database, to integrate these data with location information(topographic and demographic), and to make them user-friendly accessible. The system consists of several main functions: display of five major Korean petrochemical complex layout display of equipment layout with its information utilizing the external database, zonation of the hazard effected area with consequence analyses, the most probable accident scenario generation, accident/incident database and calculation of frequency of accident using equipment reliability database, etc. The highlight of IRMS is to provide the risk contours using GIS(Geographical Information System) technology. IRMS is intended to manage hazardous installation more systematically and effectively, to reduce the number of accident remarkably, further minimizing production loss in the plant. The system is now under application to about 500 PSM sites as well as and emergency authorities in Korea by KOSHA (Korea Occupational Safety and Health Agency)

Towards Key Issues of Disaster Aid based on Wireless Body Area Networks

  • Liu, Jianqi;Wang, Qinruo;Wan, Jiafu;Xiong, Jianbin;Zeng, Bi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권5호
    • /
    • pp.1014-1035
    • /
    • 2013
  • With recent advances in wireless communication and low-power miniaturized biomedical sensor and semiconductor technologies, wireless body area networks (WBAN) has become an integral part of the disaster aid system. Wearable vital sign sensors can track patients' status and location, thus enhancing disaster rescue efficiency. In the past few years, most of the literatures in the area of disaster aid system based on WBAN have focused on issues concerning wireless sensor design, sensor miniaturization, energy efficiency and communication protocols. In this paper, we will give an overview of disaster aid, discuss about the types of network communication as well as outline related issues. We will emphasize on analyzing six key issues in employing the disaster aid system. Finally, we will also highlight some of the challenges that still need to be addressed in the future in order to help the disaster aid system be truly and widely accepted by the public.

각광받는 한국의 기술용역업 (Spotlighting Engineering Service Business in Korea)

  • Cho Kyu Shim
    • 한국기술사회:학술대회논문집
    • /
    • 한국기술사회 1987년도 제17회 한일기술사 합동 심포지움
    • /
    • pp.65-71
    • /
    • 1987
  • All Korean professional engineer′s great joy Is to welcome the Japanese professional engineers and relevant guests to the 1987 Japan-Korea Professional Engineers Joint Convention organized by the Korean Professional Engineers Association. As there exists an effort of blood, sweat and tear behind a succeeded theatrical stage, so an exquisite devotion with drawing up a master plan, investigation, supervision and etc by engineering firms is soaked through every part of huge construction projects and large unit factory buildings. It is over 14 years that the Engineering Service Promotion Law has been enacted by the Ministry of Science and Technology. In the meantime, the domestic engineering (engineering service) have reached a remarkable higher level while the number of engineering firms participating in overseas market has gradually been increasing. From a small scale of under water investigation to a large scale planning of atomic reactor or petrochemical plant, engineering service business can be said "The Software of Total Industry." Engineering service is what is called a higher business which offers specialized engineering know-how and experience. Engineering service compaines offer Its specialized knowledge and experience to government, industry and commerce. Whether the task is to modernize plant equipment, to design a building or to manage construction, an engineering company will develop and implement the most appropriate and cost effective solution. Clients use the engineering service of firm knowing that the engineer′s professional judgement is not influenced or biased by other commercial affiliations. While benefiting from the diverse experience that professional engineers can apply to a specific problem, government and industry also reduce the need for permanent in-house engineering staff. Engineering firms may be specialized or multi-disciplinary.

  • PDF

방폭 패널 통합 제어기 설계 (Design of Integration Controller of Explosive Proof Panel)

  • 박귀만;배영철
    • 한국전자통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.267-272
    • /
    • 2020
  • 현재 석유화학산업단지는 폭발성 가스와 가연성 가스로인하여 언제나 폭발 위험성이 상존하고 있다. 이러한 폭발을 방지하고자 제어기 및 제어기 패널을 포함한 모든 설비에 방폭을 요구하고 있다. 방폭용으로 현재 사용하고 있는 제어기 패널은 패널의 내부와 외부의 압력(양압)과 온도를 일정하게 유지를 위해 외부에서 수동으로 공기를 주입하는 방식을 사용하고 있다. 이에 본 논문은 자동으로 압력과 온도를 제어할 수 있는 방폭형 패널의 통합 제어기 설계를 제안한다.

수입국 환경제도수준 변화가 수출에 미치는 영향 연구 (A study on the effect of changes in the level of environmental regulation of the importing country on export performance)

  • 황윤섭;유천
    • 무역학회지
    • /
    • 제45권4호
    • /
    • pp.65-81
    • /
    • 2020
  • Under New Climate Regime, countries are trying to enhance environmental regulations to meet international standards. This study is designed to examine the relationship between the relative level of environmental regulation of the importing countries and the export performance at the industrial level. Panel data from 2009 to 2018 was established for 12 top export industries and empirical analysis was conducted. For the analysis method, panel OLS, Hausman-Taylor, and panel GLS were used based on the results of the Hausman verification. The dependent variable is the export performance of each industry. As the independent variables, the relative level of environmental regulation, GDP per capita of the importing country, exchange rate, FTA agreement, and physical distance from the importing country were used. Results show that the relative level of environmental regulation has a negative effect on export performance of semiconductors, displays, special machines, general machines, electric appliances, and home appliances. On the other hand, there are no relationship between the relative level of environmental regulation of the importing country and export performance of automobile, petroleum refining, petrochemical, shipbuilding, and communication equipment industries.

피크패턴법을 이용한 절연유 중 PCBs 분석 (Analysis of the polychlorinated biphenyls in transformer oils using peak matching method)

  • 신선경;김혜진;정다위;전태완;김진경;박석운;정영희;정일록
    • 분석과학
    • /
    • 제18권5호
    • /
    • pp.410-418
    • /
    • 2005
  • PCBs는 뛰어난 물리 화학적, 열적 안전성과 전기 절연성으로 인해 윤활유, 열교환유체, 복사지 등 많은 용도로 사용되어 왔으며, 1930년대에서 1970년대까지 Aroclors, Kaneclors, Clophens, Phenaclors 등과 같은 상업적 PCBs 생산품들이 절연유로 사용되었다. 본 연구에서는 PCBs의 주된 배출원인 변압기 절연유를 채취하여 Aroclor 1242, 1248, 1254, 1260의 표준물질을 사용하여 정성분석을 하였다. 제작년도 및 제작사별로 채취 분석한 결과 절연유는 Aroclor 1242, Aroclor 1254, Aroclor 1260의 단일 제품을 함유하거나 이들이 혼합되어 함유되어 있는 것으로 조사되었다. 또한, 시판되는 스크리닝 키트(20 ppm, 50 ppm)를 이용한 절연유 시료 분석방법의 적용성을 검토하였다.

여수지역 비정규직 플랜트 건설 근로자의 안전보건 실태와 개선방안 (Health Status and Improvement Measures for Irregular Plant Construction Workers at Yeosu National Industrial Complex)

  • 최상준;김신범
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.182-194
    • /
    • 2009
  • This study was conducted to evaluate health status and to propose health protection measures of irregular plant construction workers in Yoesu National Industrial Complex (YNIC). The status of safety and health management was examined in five areas including safety and health education, work environment monitoring, health examination, health management record, and personal protective equipment (PPE) for plant construction workers. The safety training rate for plant construction workers was reached high at 91%, The training was mostly consisted of safety accident related things, but training on hazardous materials was found to be insufficient. Workplace monitoring results showed that the compliance rate for work environment for irregular construction workers was 54% and workplace monitoring during turnaround (TA) period with high risk of exposure to hazardous agents has not been implemented. While 61.4% of irregular workers received the general health examination but only 36.8% received the special health examination. The special health examination was found to be conducted only upon welders from 2-3 years ago. The issue of health management record upon irregular construction workers was not being implemented. In case of PPE, basic safety protective equipments such as safety shoes, safety belt, safety helmet were being supplied well while the supply rate of respirator for organic vapor was relatively low at 40%. Based on this study, two suggestions to maximize the utilization of the current safety and health program were made while boosting its effectiveness in protecting workers' health. First, the role of owners (petrochemical plant) related to safety and health should be strengthened. Second, in consideration of the characteristics of construction workers who usually engage in short term employment and frequent movement, community based health management organization is suggested that can overcome such structural problem and carry out the implementation of health examination and sustained health management.

증기운 폭발에 의해 발생된 폭풍 과압 예측 모델 검토 (A Review of the Different Models for Predicting Blast Overpressures Caused by Vapor Cloud Explosions)

  • 박달재;이영순;임영훈
    • 한국가스학회지
    • /
    • 제4권4호
    • /
    • pp.50-57
    • /
    • 2000
  • 가연성 증기 또는 가스 누출로 인해 발생하는 증기운 폭발은 엄청난 과압을 생성시켜 사고 영향이 매우 크기 때문에 공정 중에 잠재하고 있는 사고의 위험요소를 발굴하여 제거하여야 한다. 이를 위해서는 사고 결과 영향평가가 선행되어야 한다. 이러한 평가를 수행하기 위해서는 신뢰할만한 예측 도구(Tool)가 필요하다(13). 현재 여러 가지 사고결과 피해예측 모델이 제시되어 활용되고 있는 바 이러한 예측 모델(TNT-Equivalency, TNO Hemispherical, TNO Multi-Energy, CFD)이 어느 정도 타당성이 있는지에 대한 검토가 필요하다. 따라서 본 연구에서는 증기운 폭발 위험성 정량화를 위해 사용된 각 모델을 비교 검토하여 여러 가지 모델의 가정 및 정확성을 알아보고 가장 타당성 있는 모델을 선정 하고자 한다.

  • PDF

전기비저항법을 이용한 고압반응기 열화도 현장평가 (Degradation Evaluation of High Pressure Reactor Vessel in field Using Electrical Resistivity Method)

  • 박종서;백운봉;남승훈;한상인
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.377-383
    • /
    • 2005
  • 석유화학 및 정유설비는 고온이나 고압에서 폭발 위험성을 지닌 유체를 사용하기 때문에 방재기술에 관한 관심이 높다. 이들 설비 중에서도 고압반응기는 특히 고온/고압 하에서 사용되므로 안전성이 요구된다. 본 연구에서는 석유화학 플랜트의 고압반응기 소재로 많이 사용되고 있는 2.25Cr-1Mo강을 대상으로 하였으며, 3가지 온도조건에서 열화시간을 달리하여 총 8 종류의 인공열화 시험편을 준비하였다. 열화는 고압반응기의 사용온도인 $391^{\circ}C$보다 약간 높은 온도에서 둥온 열처리하였다. 미열화재를 포함하여 인공열화재에 대해 비커스경도값과 전기비저항값을 측정하였으며, Larson-Miller parameter와의 상관관계로부터 master curve를 작성하였다. 그리고 현장의 고압반응기에서 비커스경도와 전기비저항을 측정하여 실험실에서 작성한 master curve와 비교하였다. 전기비저항법을 이용한 고압반응기의 현장에서의 열화평가 가능성을 검토하였으며, 현장에서 측정한 전기비저항은 비슷한 열화수준에서의 인공열화재의 전기비저항값과 비슷하였다.

H2S 독성가스감지기가 필요한 정량적 공정설비 기준 및 비상시 안전을 위한 위치선정 방안에 대한 연구 (A Study on the Quantitative Process Facility Standards that Require H2S Toxic Gas Detectors and Location Selection for Emergency Safety)

  • 최재영;권정환
    • 한국가스학회지
    • /
    • 제22권2호
    • /
    • pp.90-96
    • /
    • 2018
  • 천연가스 및 석유를 정제 및 가공하는 화공플랜트에서 원료에 함유된 황화수소($H_2S$)의 누출로 인한 피해를 최소화시키기 위한 설계 기법들이 세계적으로 널리 연구되어왔다. 그러나 국내에서는 화공플랜트에서 $H_2S$ 가스 피해 최소화를 위한 별도의 뚜렷한 설계 지침 및 규제가 없는 실정이다. 그러므로 본 연구는 $H_2S$ 독성가스감지기를 설치해야 할 공정설비의 $H_2S$ 가스 함량의 정량적 기준을 500 ppm으로 제시하고 타당한 근거를 설명하였다. 또한 ALOHA 프로그램을 사용하여 과거 $H_2S$ 가스 누출 사고를 재구성하여 IDLH 값인 100 ppm까지의 확산 반경을 산출하였다. 모델링의 기상 조건은 국내 3대 석유화학단지가 위치한 울산, 여수, 대산의 조건을 각각 적용하였으며, 울산, 대산, 여수 순서로 긴 반경이 도출되었다. 비상시 안전을 위해서 본 연구에서 얻은 $H_2S$ 가스의 100 ppm까지의 확산 반경을 고려한 추가적인 $H_2S$ 독성가스감지기가 설치되어야 하고, 이때는 반드시 지역별 기후조건이 고려되어야 할 것이다.