• Title/Summary/Keyword: Permeameter

Search Result 53, Processing Time 0.021 seconds

Effects of Column Boundary Flow and Surfactant Contents on Soil Hydraulic Conductivity (토양 칼럼의 경계흐름과 계면활성제가 수리전도도에 미치는 영향연구)

  • Jeong, Seung-Woo;Ju, Byung-Kyu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.73-79
    • /
    • 2009
  • The hydraulic conductivity of porous media is the most important property in soil characteristics. The hydraulic conductivity is determined by outdoor and indoor methods. Indoor methods normally use soil columns for flow test. Assumption of the column test is that fluid one-dimensionally flows through the column. However, fluids may flow toward the wall of the column, resulting in "boundary flow". This study investigated the effect of boundary flow on the hydraulic conductivity by using a permeameter excluding boundary flow. The results showed that the hydraulic conductivity excluding boundary flow was much smaller than the hydraulic conductivity employing the conventional determination method. This study also investigated the effects of particle size and surfactant on the hydraulic conductivity. As the particle size increased, the hydraulic conductivity was increased. The hydraulic conductivity was reduced by increasing surfactant concentration. The result showed that the viscosity of fluid significantly affected the determination of hydraulic conductivity.

Effects of Waste Leachate on Permeability of Marine Clay (해성점토의 투수성에 대한 폐기물 침출수의 영향)

  • 강병희;장경수
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.37-42
    • /
    • 1995
  • The laboratory hydraulic conducti vita tests with rigid wall permeameter were performed to study the effects of waste leachate on the permeability of a marine clay. The marine clay and waste leachate for this study were sampled from Kimpo Wastefills, and the hydraulic gradients applied to the clay specimens aTe relatively high from 37.5 to 225. The test results show that the permeability of a marine clay is increased with increasing the concentration of leachate and with decreasing the hydraulic gradient. And also both the liquid limit and the plasticity index of the marine clay miRed with waste leachate decrease with increasing the concentration of leachate.

  • PDF

Permeability Characteristics of Sand- Bentonite Mixtures

  • Chang, Pyoung-Wuck;Chae, Yong-Suk
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.26-31
    • /
    • 1997
  • Abstract A series of permeability tests was performed on the mixtures with specific mixing rates of sand and bentonite using modified rigid-wall permeameter. Sand-bentonite mixtures were permeated by organics, ethanol and TCE. Permeability of bentonite with several mixing rates had a tendency to decrease up to initial one pore volume and permeability was thereafter converged to a constant value. When sand-bentonite mixtures was permeated by water, permeability was decreased at the beginning but it was thereafter converged to a constant. Among several mixing rates, permeability was greatly decreased at 15% of mixing rate. When sand-bentonite mixtures with 15% mixing rate was permeated by ethanol, permeability was about 10 times larger value than permeability of water. Peameability was shown greater values when permeated by TCE (TrichloroEthylene) followed by ethanol. Suitable mixing rate of sand-bentonite for a liner of waste landfills was detected.

  • PDF

Efficient Optimum Design of Reinforced Concrete Structures using the Mixed-Discrete Optimization Method

  • Kim, Jong-Ok
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.32-43
    • /
    • 1997
  • Abstract A series of permeability tests was performed on the mixtures with specific mixing rates of sand and bentonite using modified rigid-wall permeameter. Sand-bentonite mixtures were permeated by organics, ethanol and TCE. Permeability of bentonite with several mixing rates had a tendency to decrease up to initial one pore volume and permeability was thereafter converged to a constant value. When sand-bentonite mixtures was permeated by water, permeability was decreased at the beginning but it was thereafter converged to a constant. Among several mixing rates, permeability was greatly decreased at 15% of mixing rate. When sand-bentonite mixtures with 15% mixing rate was permeated by ethanol, permeability was about 10 times larger value than permeability of water. Peameability was shown greater values when permeated by TCE (TrichloroEthylene) followed by ethanol. Suitable mixing rate of sand-bentonite for a liner of waste landfills was detected.

Classification of Soil Series by the Hydraulic Properties (수리학적 토양통군의 분류)

  • Park, Seung-Ki;Jeong, Jae-Hun;Lee, Chang-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.217-220
    • /
    • 2002
  • This study was carried out to investigate the characteristics of the field-saturated hydraulic conductivity$(K_{fs})$ and matric flux potential$({\Phi}_m)$ measured by the Guelph Permeameter at the Backokpo watershed in the Han river and at the Bangdong watershed in the Keum river. And the Alpha $({\alpha})$ value which is the ratio of $K_{fs}$ to ${\Phi}_m$ were determined and the ${\alpha}$ values along with the defined soil series could be utilized to classify the soil in the Korean watershed into the SCS hydrologic soil groups.

  • PDF

Shape factors of cylindrical permeameters

  • Silvestri, Vincenzo;Samra, Ghassan Abou;Bravo-Jonard, Christian
    • Geomechanics and Engineering
    • /
    • v.3 no.1
    • /
    • pp.17-28
    • /
    • 2011
  • This paper presents an analytical solution for steady state flow into a close-ended cylindrical permeameter. The soil medium is considered to be uniform, isotropic, and of infinite thickness. Laplace equation is solved by considering rotational symmetry and by using curvilinear coordinates obtained from conformal mapping. The deduced shape factors, which are compared to approximate relationships obtained from both numerical and physical modelling, and idealizations involving ellipsoidal cavities, are proposed for use in field measurements. It is shown that some of the shape factors obtained are significantly different from published values and show a much higher dependence of the rate of flow on the aspect ratio, than deduced from approximate solutions.

폐기물 매립지 침출수와 침출수 내의 휴믹물질이 GCL의 투수계수에 미치는 영향

  • 한영수;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.208-211
    • /
    • 2001
  • Geosynthetic Clay Liners (GCLs) have been used for the applications of the hydraulic containment system in landfill due to inexpensive costs, simple workability and distinguished ability as a barrier material. However, bentonite of GCLs is easy to be damaged by the chemical solutions. Thus, there is a need to evaluate the potential susceptibility of GCLs causing Increase the hydraulic conductivity when GCLs are exposed to raw leachate and dissolved humic substances from landfill leachate. The hydraulic conductivity tests were performed with flexible-wall permeameter (the falling -headwater/rising -tailwater procedure) in order to verify the potential susceptibility of GCLs. The values of the hydraulic conductivity conducted with raw leachate as a permeant liquid increased considerably; however, The change of the hydraulic conductivity in the case of humic and fulvic acid were not worthy of notice. As the results of swelling tests of bentonite, however, humic substances can affect badly on the dispersion behavior of bentonite. These results indicate that humic substances dissolved in leachate could reduce the hydraulic conductivity of GCLs in landfill.

  • PDF

Modeling Effective Rainfall for Upland Crops (밭에서의 유효우량 산정모형 개발)

  • 정하우;김성준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.1
    • /
    • pp.29-39
    • /
    • 1993
  • A model for estimating daily effective rainfall of upland crops was developed. The infiltration process was described by Green-Ampt infiltration model developed by Chu(1978). The model considers delayed surface ponding and surface detention storage under a uniform soil profile. The Green-Ampt parameters, that is, average hydraulic conductivity and average capillary pressure head on a sandy loam soil were determined from field experiment using Air-entry permeameter developed by Bouwer(1966). The model was verified by comparing measured and simulated surface runoff. The ratios of effective rainfall to total rainfall for red pepper, soybean, sesame and Chinese cabbage were evaluated using Borg's root growth model( 1986) respectively. The followings are a summary of this study results; 1.In a sandy loam soil average hydraulic conductivity was 3.28cm/hr and average capillary pressure head was 3.00cm. 2.The root growth of upland crops could be expressed by Borg's root growth model successively. 3.The measured and simulated surface runoff was agreed well with each other. 4.As the rainfall amount was increased, the ratio of effective rainfall to total rainfall was decreased exponentially till a certain growing period.

  • PDF

Soft Magnetic Applications for RF IT devices

  • Masahiro Yamaguchi;Kim, Ki-Hyeon;Seok Bae;Shinji Ikeda;Arai, Ken-Ichi
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.11-11
    • /
    • 2002
  • Huge applications of soft magnetic films can be expected as integrated passives in the infest IT devices, including CMOS compatible RF integrated inductors and transformers, transmission line devices, electromagnetic noise countermeasure, sensors, etc. A new 1MHz-9GHz permeameter has been completed and clarified the possibility of modern magnetic films for applications in integrated passives. The films evaluated include CoNbZr, CoZro, CoAlPdO, electroplated NiZn(Co) ferrite, etc. (omitted)

  • PDF

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.