• Title/Summary/Keyword: Periprosthetic fracture

Search Result 29, Processing Time 0.026 seconds

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

Periprosthetic Occult Femoral Fracture: An Unknown Side Effect of Press-Fit Fixation in Primary Cementless Total Hip Arthroplasty

  • Ho Hyun Yun;Woo Seung Lee;Young Bin Shin;Tae Hyuck Yoon
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.88-98
    • /
    • 2023
  • Purpose: The objectives of this study were to examine the prevalence and risk factors for development of periprosthetic occult femoral fractures during primary cementless total hip arthroplasty (THA) and to assess the clinical consequences of these fractures. Materials and Methods: A total of 199 hips were examined. Periprosthetic occult femoral fractures were defined as fractures not detected intraoperatively and on postoperative radiographs, but only observed on postoperative computed tomography (CT). Clinical, surgical, and radiographic analysis of variables was performed for identification of risk factors for periprosthetic occult femoral fractures. A comparison of stem subsidence, stem alignment, and thigh pain between the occult fracture group and the non-fracture group was also performed. Results: Periprosthetic occult femoral fractures were detected during the operation in 21 (10.6%) of 199 hips. Of eight hips with periprosthetic occult femoral fractures that were detected around the lesser trochanter, concurrent periprosthetic occult femoral fractures located at different levels were detected in six hips (75.0%). Only the female sex showed significant association with an increased risk of periprosthetic occult femoral fractures (odds ratio for males, 0.38; 95% confidence interval, 0.15-1.01; P=0.04). A significant difference in the incidence of thigh pain was observed between the occult fracture group and the non-fracture group (P<0.05). Conclusion: Occurrence of periprosthetic occult femoral fractures is relatively common during primary THA using tapered wedge stems. We recommend CT referral for female patients who report unexplained early postoperative thigh pain or developed periprosthetic intraoperative femoral fractures around the lesser trochanter during primary THA using tapered wedge stems.

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.

Botulinum toxin as adjunct therapy in surgical management of a periprosthetic scapular spine fracture: a case report

  • Alex E. White;Christopher M. Brusalis;David S. Wellman;Samuel A. Taylor
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.87-92
    • /
    • 2023
  • Six months after undergoing reverse shoulder arthroplasty (RSA) a 73-year-old woman sustained a periprosthetic scapular spine fracture following a fall. She was treated with open reduction and internal fixation (ORIF), followed by botulinum toxin injection into the deltoid muscle to temporarily minimize strain at the fracture. Fracture union was achieved by 3 months, with excellent clinical function more than 1 year following fracture fixation and full resolution of deltoid function. Scapular spine fracture following RSA can be treated with ORIF and temporary deltoid paralysis using botulinum toxin in the immediate postoperative period to safely support fracture healing.

Femoral Periprosthetic Fractures after Total Knee Arthroplasty: New Surgically Oriented Classification with a Review of Current Treatments

  • Rhee, Seung Joon;Cho, Jae Young;Choi, Yoon Young;Sawaguchi, Takeshi;Suh, Jeung Tak
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.284-292
    • /
    • 2018
  • Purpose: As the number of total knee arthroplasties (TKAs) increases, the incidence of femoral periprosthetic fractures after TKA is also increasing. This review aimed to suggest a new surgically oriented classification system for femoral periprosthetic fractures. Methods: We investigated the classifications, and current treatment trends for femoral periprosthetic fractures after TKA by means of a thorough review of the relevant literature. Results: Numerous studies reported good results of surgical treatment with modern fixatives including locking compression plates and retrograde intramedullary nails. However, few classifications of femoral periprosthetic fractures reflect the recent developments in surgical treatment. Conclusions: We recommend that surgical management be considered the first-line treatment for femoral periprosthetic fractures after TKA. Our new classification will help in deciding the surgical treatment option for femoral periprosthetic fractures after TKA.

Intraoperative periprosthetic humeral fracture during reverse shoulder arthroplasty: a sequelae of prior biceps tenodesis

  • Serge Sultanem;Mohamad Y. Fares;Hasan Baydoun
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2023
  • Intraoperative periprosthetic humeral fractures are a rare but debilitating complication of reverse shoulder arthroplasty and can occur during multiple stages of the procedure. Prior biceps tenodesis has been found to reduce cortical humeral strength and predispose the patient to humeral fracture. We present a case of a 68-year-old female with a previous history of biceps tenodesis due to an irreparable rotator cuff tear. Months later, and after symptoms persisted, a reverse shoulder arthroplasty was performed. During the surgery and while performing final reduction, a fracture line was observed involving the hole used for the previous tenodesis procedure. The fracture was repaired, and the patient reported favorable outcomes. We report several factors that might have contributed to sustenance of this intraoperative fracture including prior biceps tenodesis, use of a press fit humeral stem, and the sex of the patient. Level of evidence: V.

Periprosthetic Acetabular Fracture after Total Hip Arthroplasty: A Report on Two Cases

  • Joonkyoo Kang;Chan Young Lee;Taek-Rim Yoon;Kyung-Soon Park
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.155-160
    • /
    • 2024
  • We report two cases of postoperative total hip arthroplasty periprostehtic fracture of the acetabulum which treated by open reduction with internal fixation without acetabular cup revision. From these cases, we should consider open reduction with internal fixation as the first treatment option in cases where spot welding of the cup to the host bone is observed.

Periprosthetic Fracture around Tumor Prosthesis, Comparison of Results with or without Cortical Strut Onlay Allograft (종양인공관절 주위 골절의 피질골 지주 중첩 동종골 이식술 유무에 따른 결과 비교)

  • Kim, Yongsung;Cho, Wan Hyeong;Song, Won Seok;Lee, Kyupyung;Jeon, Dae-Geun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.42-50
    • /
    • 2021
  • Purpose: Periprosthetic fractures of a tumor prosthesis are rare but have difficulties in achieving sound fixation because of the poor bone quality, which increases the risk of loosening or re-fracture, even after bone union. A cortical strut onlay allograft was adopted for peri-prosthetic fractures after hip arthroplasty into the periprosthetic fracture of a tumor prosthesis, assuming that it would assist in firm fixation, shorten the time to union, and increase the bone stock, thereby, lower the chance of loosening and re-fracture. Materials and Methods: This study reviewed 27 patients (30 cases) of periprosthetic fracture of tumor prosthesis. Sixteen cases (allograft group) had augmentation with an onlay allograft, while 14 cases (conventional group) had internal fixation or conservative treatment. The following were assessed; mode of periprosthetic fracture, difference in the time to union between a strut cortical onlay allograft and without it, and survival of prosthesis, complication, and functional outcome between the two groups. Results: According to the unified classification system (UCS), 21 cases were type B (70.0%; B1, 14; B2, 1; B3, 6) and 9 cases were type C. The five-, 10-year survival of the 30 reconstructions by Kaplan-Meier plot was 84.5%±4.18% and 42.2%±7.83%, respectively. The average time to bone union of the entire cohort was 5.1 months (range, 2.0-11.2 months). The allograft group (3.5 months) showed a shorter period for union than the conventional group (7.2 months) (p<0.0001). All four cases of major complications occurred in the conventional group. Two cases with loosening and anterior angulation were treated with a change of prosthesis, and another with infection underwent amputation. The remaining case with loosening had conservative management. At the final follow-up, the average Musculosketal Tumor Society score of the allograft group (26.1) was better than that of the conventional group (20.9). Conclusion: Bone union in periprosthetic fractures of a tumor prosthesis can be achieved, but the minimization of complications is important. An onlay allograft facilitates firm fixation and increases the bone stock with a shortened time to union. This simple method can minimize the risk of loosening, joint contracture, and re-fracture.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.