References
- Athwal GS, Sperling JW, Rispoli DM, Cofield RH. Periprosthetic humeral fractures during shoulder arthroplasty. J Bone Joint Surg Am 2009;91:594-603. https://doi.org/10.2106/JBJS.H.00439
- Dillon MT, Prentice HA, Burfeind WE, Chan PH, Navarro RA. The increasing role of reverse total shoulder arthroplasty in the treatment of proximal humerus fractures. Injury 2019;50:676-80. https://doi.org/10.1016/j.injury.2019.01.034
- Chen CH, Hsu KY, Chen WJ, Shih CH. Incidence and severity of biceps long head tendon lesion in patients with complete rotator cuff tears. J Trauma 2005;58:1189-93. https://doi.org/10.1097/01.TA.0000170052.84544.34
- Creech MJ, Yeung M, Denkers M, Simunovic N, Athwal GS, Ayeni OR. Surgical indications for long head biceps tenodesis: a systematic review. Knee Surg Sports Traumatol Arthrosc 2016;24:2156-66. https://doi.org/10.1007/s00167-014-3383-9
- Walch G, Edwards TB, Boulahia A, Nove-Josserand L, Neyton L, Szabo I. Arthroscopic tenotomy of the long head of the biceps in the treatment of rotator cuff tears: clinical and radiographic results of 307 cases. J Shoulder Elbow Surg 2005;14:238-46. https://doi.org/10.1016/j.jse.2004.07.008
- American Academy of Orthopaedic Surgeons. Clinical practice guideline on the management of rotator cuff injuries. American Academy of Orthopaedic Surgeons; 2019.
- Friedel R, Markgraf E, Schmidt I, Donicke T. Proximal humerus shaft fracture as a complication after keyhole-plasty: a case report. Unfallchirurgie 1995;21:198-201. https://doi.org/10.1007/BF02588699
- Reiff SN, Nho SJ, Romeo AA. Proximal humerus fracture after keyhole biceps tenodesis. Am J Orthop (Belle Mead NJ) 2010;39:E61-3.
- Sears BW, Spencer EE, Getz CL. Humeral fracture following subpectoral biceps tenodesis in 2 active, healthy patients. J Shoulder Elbow Surg 2011;20:e7-11. https://doi.org/10.1016/j.jse.2011.02.020
- Dein EJ, Huri G, Gordon JC, McFarland EG. A humerus fracture in a baseball pitcher after biceps tenodesis. Am J Sports Med 2014;42:877-9. https://doi.org/10.1177/0363546513519218
- Jacobs AN, Umlauf JA, Kniss JR. Proximal humerus fracture following arthroscopic biceps tenodesis. J Orthop Sports Phys Ther 2020;50:649.
- Erdle NJ, Osier CJ, Hammond JE. Humerus fractures after open subpectoral biceps tenodesis: three cases with 2-year functional outcome data and review of the literature. JBJS Case Connect 2020;10:e0033.
- Ashmyan RI, Kelly JP, Tucker MM, Baker CL 3rd. Humeral shaft fracture after open biceps tenodesis following use of continuous passive motion machine: a case report. JSES Int 2021;5:546-8. https://doi.org/10.1016/j.jseint.2020.12.008
- Baleani M, Francesconi D, Zani L, Giannini S, Snyder SJ. Suprapectoral biceps tenodesis: a biomechanical comparison of a new "soft anchor" tenodesis technique versus interference screw biceps tendon fixation. Clin Biomech (Bristol, Avon) 2015;30:188-94. https://doi.org/10.1016/j.clinbiomech.2014.12.001
- Chiang FL, Hong CK, Chang CH, Lin CL, Jou IM, Su WR. Biomechanical comparison of all-suture anchor fixation and interference screw technique for subpectoral biceps tenodesis. Arthroscopy 2016;32:1247-52. https://doi.org/10.1016/j.arthro.2016.01.016
- Hipp JA, Edgerton BC, An KN, Hayes WC. Structural consequences of transcortical holes in long bones loaded in torsion. J Biomech 1990;23:1261-8. https://doi.org/10.1016/0021-9290(90)90383-E
- Beason DP, Shah JP, Duckett JW, Jost PW, Fleisig GS, Cain EL Jr. Torsional fracture of the humerus after subpectoral biceps tenodesis with an interference screw: a biomechanical cadaveric study. Clin Biomech (Bristol, Avon) 2015;30:915-20. https://doi.org/10.1016/j.clinbiomech.2015.07.009
- Lee M, Chebli C, Mounce D, Bertelsen A, Richardson M, Matsen F 3rd. Intramedullary reaming for press-fit fixation of a humeral component removes cortical bone asymmetrically. J Shoulder Elbow Surg 2008;17:150-5. https://doi.org/10.1016/j.jse.2007.03.032
- King JJ, Farmer KW, Struk AM, Wright TW. Uncemented versus cemented humeral stem fixation in reverse shoulder arthroplasty. Int Orthop 2015;39:291-8. https://doi.org/10.1007/s00264-014-2593-6
- Wagner ER, Houdek MT, Elhassan BT, Sanchez-Sotelo J, Cofield RH, Sperling JW. What are risk factors for intraoperative humerus fractures during revision reverse shoulder arthroplasty and do they influence outcomes. Clin Orthop Relat Res 2015;473:3228-34. https://doi.org/10.1007/s11999-015-4448-x
- Alswat KA. Gender disparities in osteoporosis. J Clin Med Res 2017;9:382-7. https://doi.org/10.14740/jocmr2970w
- Eyberg BA, Walker JB, Harmsen SM, Gobezie R, Denard PJ, Lederman ES. Suture cerclage for stabilizing the humeral shaft during shoulder arthroplasty. JSES Int 2020;4:688-93. https://doi.org/10.1016/j.jseint.2020.03.002
- Renner N, Wieser K, Lajtai G, Morrey ME, Meyer DC. Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplasty. J Shoulder Elbow Surg 2014;23:1568-74. https://doi.org/10.1016/j.jse.2014.02.012
- Denard PJ, Nolte PC, Millett PJ, et al. A tensionable suture-based cerclage is an alternative to stainless steel cerclage fixation for stabilization of a humeral osteotomy during shoulder arthroplasty. J Am Acad Orthop Surg 2021;29:e609-17. https://doi.org/10.5435/JAAOS-D-20-00047