• 제목/요약/키워드: Periotest value(PTV)

검색결과 16건 처리시간 0.02초

$Periotest^{(R)}$를 이용한 임프란트지지 보철물의 적합도 평가에 관한 연구 (AN EVALUATION OF PRECISION FIT OF IMPLANT-SUPPORTED PROSTHESIS USING THE PERIOTEST)

  • 김영민;배정식
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.587-597
    • /
    • 1998
  • In this study, the Periotest value was measured with Periotest to evaluate precision fit of the 2-unit and 3-unit implant-supported prosthesis by modifying the size and location of ill-fitted conditions. The 2-unit prosthesis was fabricated with the right implant fitted incorrectly and the 3-unit prosthesis with the right and center implant fitted incorrectly. To evaluate the effects of the ill-fitted sizes, 4 groups were divided.:The control group being the accurately fabricated sample group fitted properly. Group 1 was constructed with $40{\mu}m$ ill-fitted conditions, group 2 with $70{\mu}m$ and group 3 with $100{\mu}m$ ill-fitted conditions. The Periotest value was measured at each implant site after tightening 10Ncm. The result was follows : 1. The PTV on the ill-fitted area in the 2-unit implant-supported prosthesis increased as the ill-fitted conditions increased. There was a statistically significant difference among groups(p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05) 2. The PTV on the ill-fitted area of the 3-unit implant-supported with an ill-fitted condition in the right implant increased as the ill-fitted conditions increased. There was a significant difference among groups (p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05). 3. In the 3-unit implant-supported prosthesis with ill fitting conditions in the center implant, the PTV on the ill-fitted area demonstrated a statistically significant difference between the control group, group 1 and group 2 (p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated significant difference between the gap side and the adjacent side with over $70{\mu}m$ ill-fitted conditions (p<0.05). The results suggest that Periotest is a valuable objective method for evaluating the precision fit of an implant superstructure.

  • PDF

즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest$^{(R)}$의 유효성 (The validation of Periotest values for the evaluation of orthodontic mini-implants' stability)

  • 차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제40권3호
    • /
    • pp.167-175
    • /
    • 2010
  • Periotest$^{(R)}$는 보철용 임플랜트 식립 3 - 4개월 후 골유착 정도를 평가하기 위해 사용되는 동요도 측정 기기로 교정용 미니임플랜트 안정성 평가에 적용가능성이 높다. 본 연구는 교정용 미니임플랜트의 안정성 평가를 위해 Periotest$^{(R)}$의 유효성을 검증하고자 하였다. 성견 다섯 마리의 상악, 하악 협측골에 교정용 미니임플랜트를 식립하고, 식립 시 식립토오크와 동요도를 측정하고 12주 동안 교정력을 부여한 후, 제거 시 제거 토오크와 동요도를 측정하였다. 동요도 (Periotest$^{(R)}$ value, PTV) 측정은 재현성을 위해 동일 부위에 2회 측정하였다. PTV와 다른 변수와의 상관성 분석을 위해 모든 실험견은 CT 촬영 후 식립 부위의 골밀도와 피질골 두께를 계측하였다. 동요도 측정에 대한 재현성은 0.96의 상관계수를 나타내 매우 높았으며 (p < 0.001) 골밀도와 피질골 두께에 있어 하악골 협측치조골이 상악골에 비해 유의하게 컸다 (p < 0.05). 12주 동안 PTV 값은 -3.2에서 4.8의 범위를 나타내며 모든 임플랜트는 임상적으로 안정적이었다. 식립 시 PTV 값은 하악에서 식립 토오크(-0.51), 골밀도(-0.48), 피질골 두께(-0.42)와 상관성이 있었으나 (p < 0.05), 상악에서는 상관성이 없었다. 제거 시 PTV 값은 하악에서 제거 토오크(-0.66)와 상관성이 있었으며(p < 0.05), 상악에서는 상관성이 없었다. 이상의 결과는 Periotest$^{(R)}$를 이용하여 교정용 미니임플랜트의 안정성을 간접적으로 평가할 수 있으나 골밀도가 높고 피질골이 두꺼운 부위에서 제한적으로 응용할 수 있음을 시사한다.

자연 치아와 골유착성 임플랜트의 동요도에 관한 연구 (MOBILITY OF NATURAL TEETH AND OSSEOINTEGRATED IMPLANTS)

  • 장경수;김용호;김영수
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.144-155
    • /
    • 1995
  • It is well known that implants showing no clinical mobility are successfully osseointegrated and have good prognosis. When implants are under load, their mobility begins to increase. It is of necessity to substantiate whether excessive load is on or premature occlusal force is acting prior to desirable osseointegration. Using Periotest unit, we could measure the pattern of mobility change. Consequently, osseointegrated treatment has come to success by intercepting progressive mobility and doing perceptive treatment according to the result of Periotest Value(PTV). In this study, we took records of intangible mobility of 70 osseointegrated implants. And we also measured the mobility of periodontally sound natural teeth as a standard from 30 dental personnel. Conclusions were summarized as followings ; 1. Lower lateral incisor has the highest PTV, whereas lower canine, upper canine, lower premolars and lower 1st molar have the lowest PTV in natural dentition. 2. There are little significant statistical difference of PTV between men and women in both(natural and implant) dentition. 3. In general, lower natural teeth show lower PTV than upper counterpart. 4. Mandibular implants have lower PTV than those of maxillary implants. 5. All of the successfully osseointegrated implants have lower PTV than those of periodontally healthy teeth.

  • PDF

$Periotest^(R)$ Value와 Implant Stability Quotient에 영향을 미치는 요소 (THE INFLUENCING FACTORS OF $PERIOTEST^(R)$ VALUE AND IMPLANT STABILITY QUOTIENT)

  • 이영아;차인호;이호용;한동후
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.40-50
    • /
    • 2006
  • Statement of problem: $Periotest^(R)\;and\;Osstell^{TM}$ were known as the most objective and quantitative mobility tests available for evaluating stability of implant in vivo. Although a correlation between PTV widely used and ISQ recently introduced exist, a PTV was corresponded to various ISQ. A correct evaluation of implant stability could be obtained only after one has a thorough understanding of the limitations of devices and factors that affect measurements. Purpose: The purpose of this study was to investigate the causes of variables in the values obtained with these two tests. Material and method: A total of 333 implants 134 $Br{\aa}nemark$, 5 Silhouette and 194 ITI implants were investigated. Result: 1. There was a correlation between PTV and ISQ (Spearman correlation =0.39, p<0.0001) 2. The factors that affected ISQ were diameter of implant future, location of implant and implant system (submerged type vs non-submerged type). 3. The factors that affected W were dimeter of implant future, location of implant, and elapsed time after implant placement. 4. There was no significant difference between different surface treatments of RBM, smooth surface and ti-unite on PTY and ISQ. 5. In radiographic finding, no saucerization or bone resorption has been detected in implants with ISQ values that were above the average level of each PTV. These higher values had higher bone densities around the implant fixture. Saucerization was observed in the most impants with ISQ values that were below the average level of each PTV. Conclusion: There was a correlation between ISQ and PTV. However, each measuring methods had factors influencing the measured values. PTV were less sensitive to marginal bone resorption and influenced with the striking point on an implant to the level of bone. With ISQ, the height of implant from bone level to transducer should be considered.

치주재생 치료를 받은 치아의 동요도와 다른 치주임상적 지표 간의 상관관계 (Correlation Between Tooth Mobility and other Periodontal Clinical Parameters of Teethhaving Periodontal Regenerative Treatment)

  • 손병찬;김성조;최점일;이주연
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.37-46
    • /
    • 2012
  • 치주치료의 궁극적 목표는 치주질환으로 상실된 치주조직의 재생이라고 볼 수 있다. 치주재생술식 후 회복을 평가하는 단계에서, 탐침과정이 초기 회복기의 신생조직에 위해한 영향을 줄 수 있다. 치아동요도는 치주조직이 치아를 지지하고 있는 상태를 평가하는 중요한 지표로 사용된다. 이에 본 연구에서는 치아동요도와 다른 임상지표간의 상관관계를 조사하고, 치아동요도를 측정하는 Periotest$^{(R)}$가 재생술식 후 초기 회복기에 탐침의 필요성을 배제할 수 있는지를 조사하고자 하는 것이다. 치주재생수술을 받은 25명의 환자, 29개의 치아를 대상으로 하였다. 부착수준, 치주낭 심도, 치아동요도 (Periotest$^{(R)}$ value PTV)등의 임상지표를 연구시작단계, 시술 후 6개월, 12개월에 측정하였다. 재생수술 후 모든 임상지표들이 개선되었고 (p<0.05), 각각의 시기에 부착수준, 탐침깊이, 치은퇴축과 PTV 사이의 통계적으로 유의한 상관관계가 관찰되었다. 또한 각 시기 사이의 임상지표와 PTV변화량의 상관관계에서 치주낭깊이와 부착수준이 상관관계가 있는 것으로 관찰되었다. 이상의 결과들로 치주재생술식 이후 임상지표들의 개선을 기대할 수 있으며, 재생술식 이후 회복기에 임상지표의 측정에 PTV가 보조적 역할을 할 수 있을 것으로 사료된다.

The reliability of Anycheck device related to healing abutment diameter

  • Lee, Dong-Hoon;Shin, Yo-Han;Park, Jin-Hong;Shim, Ji-Suk;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.83-88
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

발치와 치조제 보존술 시행 후 식립한 임플란트의 방사선학적 및 임상적 후향적 연구 (Retrospective radiographic and clinical analysis of implant survival placed after alveolar ridge preservation)

  • 이성조;장현;신현;박정철;송영균;조인우
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.167-174
    • /
    • 2018
  • 목적: 발치와에 치조제 보존술을 시행한 부위에 식립한 임플란트의 일정 기간의 생존율을 초기고정 값과 방사선학적 계측을 통해 분석해보고자 하였다. 연구 재료 및 방법: 19명의 환자에 sandblasted, large-grit, acid-etched (SLA) 표면을 갖는 단일 제품의 21개의 임플란트를 조사하였다. 임플란트는 치조제 보존술(Alveolar ridge preservation technique: ARP) 시행 후 2 - 3개월의 치유 기간 후 식립 되었으며, 식립 시 및 보철 시행 전 Periotest value (PTV)와 식립 시 및 최종 점검시의 방사선 사진을 통한 Marginal bone level (MBL)의 변화를 측정하였다. 결과: 전체 임플란트의 생존율은 100%로 나타났고 식립 시의 PTV는 평균 $-0.06{\pm}8.33$이었으며 보철 시행 전 PTV는 평균 $-5.75{\pm}1.72$이었다. 근 원심 평균 MBL의 변화는 -0.55 mm에서 1.6 mm의 범위로 평균 $0.19{\pm}0.58mm$를 나타내었다. 결론: 발치와 보존술을 시행한 부위에 식립한 임플란트는 높은 생존율을 나타내며 안정적인 변연골 유지를 보이는 것으로 사료된다.

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

성견에서 즉시 부하 후 임프란트 안정성 평가 : 임상적, 방사선학적 연구 (ASSESSMENT OF IMPLANT STABILITY AFTER IMMEDIATE LOADING IN DOGS : CLINICAL AND RADIOGRAPHIC STUDY)

  • 이주영;김수관;김상호;김완배
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.131-139
    • /
    • 2005
  • The therapeutic goal of implant dentistry is not merely tooth replacement but total oral rehabilitation. Considering dental implants as a treatment option can be provided patients with positive, long-term results. Implant dentistry has gone through many phases over the years. Modern technology and design allows us to predictably place our dental implants often load the implants at the time of placement. The purpose of this study is to evaluate the implant stability after immediate loading in dogs. The control group was performed delay loading and experimental group was immediate loading. Each group was measured periotest value(PTV) to evaluate clinical mobility and performed radiographic examination to evaluate marginal bone loss. Statistically significant difference was not founded in control group between experimental group in PTV(P>0.05) and marginal bone loss(P>0.05). Finally, implant stability after immediate loading was similar to delay loading implant.

양극산화 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구 (ON THE SURFACE CHARACTERISTICS AND STABILITY OF IMPLANT TREATED WITH ANODIZING OXIDATION)

  • 김원상;조인호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.549-560
    • /
    • 2006
  • Purpose : This experiment examined the effects of anodization on commercially pure titanium implant fixtures. Material & methods : The implant fixtures were anodized at three different voltage levels, producing three different levels of oxidation on the surface of the fixure. Implant were divided into four groups according to the level of oxidation. Group 1 consist of the control group of machined surface implants, Group 2 implants were treated by anodizing to 100 voltage, Group 3 implants were treated by anodizing oxidation to 200 voltage Group 4 implants were treated by anodizing oxidation to 350 voltage. Surface morphology was observed by Scanning Electron Microscope(SEM) and the surface roughness was measured using NanoScan $E-1000^{\circledR}$. Implantation of the fixtures were performed using New Zealand white rabbits. $Periotest^{\circledR}$ value(PTV) resonance frequency analysis(RFA), and removal torque were measured in 0, 2, 4, 8, 12 weeks after implantation. Results : The results of the study were as follows: 1. Values for the measured surface roughness indicate statistically significant differences in Ra, Rq, and Rt values among group 1, 2, 3, and 4 at the top portion of the thread,(p<0.05) while values at the base of the threads indicated no significant difference in these values. 2. A direct correlation between the firming voltage, and surface roughness and irregularities were observed using scanning electron microscope. 3. No statistically significant differences were found between test groups regarding $Periotest^{\circledR}$ values. 4. Analysis of the data produced by RFA, significant differences were found between group 1 and group 4 at 12 weeks after implantation.(p<0.05) Conclusions : In conclusion, no significant differences could be found among test groups up to a certain level of forming voltage threshold, beyond this firming voltage threshold, statistically significant differences occurred as the surface area of the oxide layer increased with the increase in surface porosity, resulting in enhanced bone response and osseointegration.