ASSESSMENT OF IMPLANT STABILITY AFTER IMMEDIATE LOADING IN DOGS : CLINICAL AND RADIOGRAPHIC STUDY

성견에서 즉시 부하 후 임프란트 안정성 평가 : 임상적, 방사선학적 연구

  • Lee, Joo-Young (Dept. of Oral and Maxillofacial Surgery, College of Dentistry, Chosun University) ;
  • Kim, Su-Gwan (Dept. of Oral and Maxillofacial Surgery, College of Dentistry, Chosun University) ;
  • Kim, Sang-Ho (Dept. of Oral and Maxillofacial Surgery, College of Dentistry, Chosun University) ;
  • Kim, Wan-Bae (Dept. of Oral and Maxillofacial Surgery, College of Dentistry, Chosun University)
  • 이주영 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 김수관 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 김상호 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 김완배 (조선대학교 치과대학 구강악안면외과학교실)
  • Published : 2005.03.31

Abstract

The therapeutic goal of implant dentistry is not merely tooth replacement but total oral rehabilitation. Considering dental implants as a treatment option can be provided patients with positive, long-term results. Implant dentistry has gone through many phases over the years. Modern technology and design allows us to predictably place our dental implants often load the implants at the time of placement. The purpose of this study is to evaluate the implant stability after immediate loading in dogs. The control group was performed delay loading and experimental group was immediate loading. Each group was measured periotest value(PTV) to evaluate clinical mobility and performed radiographic examination to evaluate marginal bone loss. Statistically significant difference was not founded in control group between experimental group in PTV(P>0.05) and marginal bone loss(P>0.05). Finally, implant stability after immediate loading was similar to delay loading implant.

Keywords

References

  1. Maggiolo : Le Mannual de I art du dentiste, Nancy, 1807. in new, I : Progress in implant dentistry-An elevation. J Am Dent Assoc 59 : 478, 1959
  2. Adell R, Lekholm U, Rockeler B et al : A 15-year study of ossteointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 10 : 381, 1981
  3. Branemark PI : Ossteointegration and its experimental background. J Prosthet Dent 50 : 399-410, 1983 https://doi.org/10.1016/S0022-3913(83)80101-2
  4. Lorenzoni M : In patient comparison of immediately load and non loaded implants within 6 month. Clin Oral Implant Res 14 : 1273, 2003
  5. Donath K, Laass M : The histopathology of different forign body reaction to oral soft tissue and bone tissue. Virchows Archiv Pathological Anatomy 420 : 131, 1992 https://doi.org/10.1007/BF02358804
  6. Piattelli A, Corigliano M, Scrano A : Microscopical observations of the osseous responses in early loaded human titanium implants: a report of two cases. Biomaterials 17 : 1333, 1996 https://doi.org/10.1016/0142-9612(96)88680-7
  7. Piattelli A. Corigliano M, Scrano A et al : Bone reactions to early occlusal loading of two stage titanium pasma sprayed implants: pilot study in monkeys. Int J Periodontics Restorative Dent 17 : 163, 1997
  8. Piattelli A, Paolantonio M, Corigliano M et al : Immediate loading of titanium plasma sprayed screw shaped implants in man: A Clinical and histological report of two cases. J Periodontol 68 : 591, 1997 https://doi.org/10.1902/jop.1997.68.6.591
  9. Piattelli A, Ruggeri A, Romasco N et al : A histologic and histomorphometric study of the bone reaction to non-submerged unloaded and loaded single implants in monkeys. J Oral Implantol 19 : 314, 1993
  10. Piattelli A, Scrano A, Corigliano M et al : Immediate loading of titanium plasma sprayed implants: A pilot study in monkeys. J Periodontol 69 : 321, 1998 https://doi.org/10.1902/jop.1998.69.3.321
  11. Piattelli A, Scrano A, Paolantonio M : Immediately loaded screw implant removed for fracture after a 15 year loading period; histological and histochemical analysis. J Oral Implantol 23 : 75, 1997
  12. Piattelli A, Trisi P, Romasco N et al : Histological analysis of a screw implants retrieved from man: influence of early loading and primary stability. J Oral Implantol 19 : 303, 1993
  13. Randow K, Ericsson I, Nilner K et al : Immediate functional loading of Branemark dental implants. An 18-month clinical follow-up study. Clin Oral Implan Res 10 : 8, 1999 https://doi.org/10.1034/j.1600-0501.1999.100102.x
  14. Gapski R, Wang HL, Mascarenhas P et al : Critical review of morphometric study in dogs. Int J Periodontics Restorative Dent 19 : 343, 1999
  15. Zubery Y : Immediate loading of modular trantional implants : A histological and histometric study in dogs. Int J Periodontics Restorative Dent 19 : 343, 1999
  16. Zabloski : Stegprothetische versorgung des ahnloseunderkiefers mit Hilfe von plasmabeschichteten Titanschraubenimplantaten. Dtsch Zahnarztl Z 34 : 907, 1979
  17. Albrektsson T : Osteointegrated dental implants. Dent Clin North 30 : 151, 1986
  18. Boyan BD, Degidi M: Response of bone and cartilage cells to biomaterials in vivo and in vitro. J Oral Implants 19 : 116, 1993
  19. Schenk R : Healing pattern of regeneration in membrane protected defects: A histologic study in the canine mandible. Int J Oral Maxillofac Implants 9 : 13, 1994
  20. Steinemman SG : Titanium-the material of choice? Periodontology 2000 17 : 7, 1998 https://doi.org/10.1111/j.1600-0757.1998.tb00119.x
  21. Andersen E, Brunski JB, Becker W : Immediate loading of single tooth ITI implants in the anterial maxilla: a prospective 5-year pilot study. Int J Oral Maxillofac implants 8 : 45, 1993
  22. Babbush CA, Kent J, Misiek D : Titanium plasma prayed(TPS) screw implants for the reconstrutction of the edentulous mandible. Int J Oral Maxillofac Surg 44 : 274, 1986 https://doi.org/10.1016/0278-2391(86)90078-9
  23. Joseph C, Buser D, Tzohar A et al : Extraction immediate- load implants, impressions and final restorations in two patient visits. JADA 134 : 715, 2003
  24. Nowzari H, Romasco N, Ortman I : Clinical and microbiological aspects of the sargon immediate load implant. Dental implants 19 : 686, 1998
  25. Pierrisnard L, Garber DA, Ganeles J : Two dental implants designed for immediate loading: A Finite element analysis. Int Oral Maxillofac implants 17 : 353, 2002
  26. Lorenzoni M : In patient comparision of immediately loaded and non-loaded implants within 6 months. Clin Oral Implant Res 14 : 273, 2003 https://doi.org/10.1034/j.1600-0501.2003.140304.x
  27. Ericsson I, Becker W : Immediate functional loading of Br¨anemark single tooth implants : an 18 months clinical pilot follow-up study. Clin Oral Res 22 : 26, 2002
  28. Schnitmann PA : Immediate fixed interim prostheses supported by two-stage threaded implants: Methodology and results. J Oral Implantol 16 : 96, 1990
  29. Randow K, Ericsson I, Nilner K et al : Immediate functional loading of Branemark dental implants. An 18-month clinical follow-up study. Clin Oral Implan Res 10 : 8, 1999 https://doi.org/10.1034/j.1600-0501.1999.100102.x
  30. Bronski, Nowzari H, Romasco N et al : Clinical and microbiological aspects of the sargon immediate load implant. Dental Implants 19 : 686, 1998
  31. Schatzer J, Lundgren D, Rylander H : The effect of movement of the holding power of screw in bone. Clin Ortho Res 3 : 257, 1975
  32. Olive J : The periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 5 : 390, 1990
  33. Akakawa Y, Hashimoto M, Konto N : Initial bone-implant interfaces of submergible and supramergible endosseous single crystal sapphire implants. J Prosthet Dent 55 : 96, 1986 https://doi.org/10.1016/0022-3913(86)90083-1
  34. Tarnow DP : Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1 to 5 year data. Int J Oral Maxillofac implant 12 : 319, 1997
  35. Lendermann PD : Sechsjaehrige klinische Erfahrung mit dem titanplasmabeschichteten ITI-Schrauben implantat in der Regio interforaminalis des Unterkiefers. Schweiz Monatsschr Zahnmed 93 : 1080, 1983
  36. Graber G, Besmino C : Hybridprothetische Suprastrukturen mit Konuskronen oder Hulsen-stift-systemen auf Ha-Ti implantaten. Fortsch Zahnarztl Implantol 7 : 125, 1991
  37. Skalak R : Biomechanical considerations in osseointegrated protheses. J Prosthet Dent 49 : 843, 1983 https://doi.org/10.1016/0022-3913(83)90361-X
  38. Schulte W : Actiology of periodontal diseases. The position and evaluation of endogenous factors. Deutsche Zahnarztliche Zeitung 28 : 1154, 1973
  39. Degidi M, Piattelli A : Immediate functional and nonfunctional loading of dental implants: A 2- to 60-month followup study of 646 titanium implants. J Peroodontol 74 : 225, 2003 https://doi.org/10.1902/jop.2003.74.2.225
  40. Pillar RM, Lee GM : Observations on the effect of movement on bone ingrowth into porous surfaced implants. Clin Ortho Res (208) : 108, 1986
  41. Szmukler-Moncler S, Salama H : Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43 : 192, 1998 https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
  42. Pillar RM, Deporter D, Watson PA : Tissue-implant interface : Micromovement effects. In: Vicenzini P. Advanced in science and technology. Vol 12: Materials in clinical applications: Proceedings of the 8th CIMTEC WORLD CERAMICS CONGRESS and Forum on new materials. Florence, Italy, June 28 to July 4,1994. Faenza, Italy:Techna, 569-579, 1995. J Periodontol Feb. 225-241, 2003
  43. Schulte W : Periotest values and tooth mobility in periodontal disease : A comparative study. Quintessence Int 21 : 289, 1990
  44. Schulte W : Periotest for measuring periodontal characteristics correlation with periodontal bone loss. J Periodon Res 27 : 184, 1992 https://doi.org/10.1111/j.1600-0765.1992.tb01667.x
  45. Ahn JH, Kim HJ, Park JC et al : Healing of the bone around pure titanium implants without primary bone contact. J Korean Aca Periodontol 29(1) : 233, 1999
  46. Teerlinck J, Quirymen M, Daris P : Periotest: an object clinical diagnosis of bone apposition toward implants. Int J Oral Maxillofac implants 6 : 55, 1991
  47. Chavez H, Ortman I : Assessment of oral implant mobility. J Prosthet Dent 70 : 421, 1989
  48. Ericsson I, Randow K, Nilner K et al : PetersonA. Immediate functional loading of Branemark single tooth implants: an 18 months clinical pilot follow-up study. Clin Oral Implant Res II: 26, 2000
  49. Lorenzoni M, Walter A, Pertl C : Immediate loading of single tooth implants in the anterial maxilla. Preliminary results after one year. Clin Oral Implant Res 14 : 180, 2003 https://doi.org/10.1034/j.1600-0501.2003.140207.x
  50. Weber HP, Buser D, Donath K : Comparison of healed tissues adjacent to submerged and non-submerged unloaded titanium dental implants. A histometric study in beagle dogs. Clin Oral Implants Res 7 : 11, 1996 https://doi.org/10.1034/j.1600-0501.1996.070102.x
  51. Cooper L, Felton DA, Kugelberg CE : A multicenter 12- month evaluation of single tooth implants restored 3 weeks after I surgery. Int J Oral Maxillofac Implants 16 : 182, 2001
  52. Chaushu G, Tzohar A, Dayan D : Immediate loading of single tooth implants: immediate vs. non-immediate implantation. A clinical report. Int J Oral Maxillofac Implants 16 : 267, 2001
  53. Kim SG, Kim YG. The Management of Implant Complications. Vol 1. Narae Publishing. 2003
  54. Roberts WE : Bone tissue interface. J Dent Edu 42 : 804, 1998
  55. Murray G, Stefan T, Garbor T : Experimental and clinical study of new growth of bone in a cavity. Am J Surg 93 : 45, 1957
  56. Arthur B, Garbor F, Stefan T : Histomorphometric analysis of the bone-implant contact obtained with 4 different surface treatments placed side by side in the dog mandible. Int J Oral Maxillofac implants 17 : 377, 2002
  57. Werner Z, Tangl S, Garbor T et al : Osseous healing characteristics of three different implant types : A histologic and histometric study in mini-pigs. Clin Oral Impl Res 14 : 150, 2003 https://doi.org/10.1034/j.1600-0501.2003.140203.x