• Title/Summary/Keyword: Periodic Testing

Search Result 80, Processing Time 0.026 seconds

Actual Condition of Periodic Visual Acuity Testing for Undergraduate Students (대학생의 정기적 시력검진 실태에 관한 연구)

  • Lee, Ok-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.117-120
    • /
    • 2007
  • The actual condition of periodic visual acuity testing for 304 undergraduate students were investigated for the purpose of prepared some fundamental data on the development of the eye-health education program and conducting a practical application. Many undergraduate students (59.21%) had not been tested periodic visual acuity testing. The ratio of periodic visual acuity testing for female was higher than male. There was statistical significant difference dependence on the native place, the educational system, and the division of major. The ratio of periodic visual acuity testing for undergraduate students from city was 43.07%, from rural area was 24.32% (p<0.05). According to the educational system, the ratio of periodic visual acuity testing of university students was 65.71%, college students was 27.64% (p<0.001). The ratio of periodic visual acuity testing of undergraduate students who have corrected their visual acuity was 50.25%, while that of students who have not corrected was 23.36% (p<0.001).

  • PDF

RPS Periodic Testing Method for Reliability and Availability (신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발)

  • Park, Joo-Hyun;Lee, Dong-Young;Lee, Seong-Jin;Song, Deok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

Optimal Release Time for Software Considering Distribution of Periodic Service Packs and Uncertain Patches during Operational Phase (사용단계에서 주기적 서비스 팩 배포와 불확실한 패치 배포를 고려한 소프트웨어의 최적 출시시기)

  • Park, Il Gwang;Kong, Myung Bock
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.33 no.4
    • /
    • pp.487-493
    • /
    • 2007
  • In this paper, we deal with an optimal software-release problem of determining the time to stop testing and release the software system to the user. The optimal release time problem is considered from maintenance like the periodic distribution of service packs and the unpredictable distribution of patches after the release. Moreover, the environment of software error-detection during operation differs from the environment during testing. This paper proposes the software reliability growth model which incorporates periodic service packs, unpredictable patches and operational environment. Based on the proposed model, we derive optimal release time to minimize total cost composed of fixing an error, testing and maintenance. Using numerical examples, optimal release time is determined and illustrated.

CONSISTENT AND ASYMPTOTICALLY NORMAL ESTIMATORS FOR PERIODIC BILINEAR MODELS

  • Bibi, Abdelouahab;Gautier, Antony
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.5
    • /
    • pp.889-905
    • /
    • 2010
  • In this paper, a distribution free approach to the parameter estimation of a simple bilinear model with periodic coefficients is presented. The proposed method relies on minimum distance estimator based on the autocovariances of the squared process. Consistency and asymptotic normality of the estimator, as well as hypotheses testing, are derived. Numerical experiments on simulated data sets are presented to highlight the theoretical results.

The Fault Tolerant Evaluation Model due to the Periodic Automatic Fault Detection Function of the Safety-critical I&C Systems in the Nuclear Power Plants (원전 안전필수 계측제어시스템의 주기적 자동고장검출기능에 따른 고장허용 평가모델)

  • Hur, Seop;Kim, Dong-Hoon;Choi, Jong-Gyun;Kim, Chang-Hwoi;Lee, Dong-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.994-1002
    • /
    • 2013
  • This study suggests a generalized availability and safety evaluation model to evaluate the influences to the system's fault tolerant capabilities depending on automatic fault detection function such as the automatic periodic testings. The conventional evaluation model of automatic fault detection function deals only with the self diagnostics, and supposes that the fault detection coverage of self diagnostics is always constant. But all of the fault detection methods could be degraded. For example, the periodic surveillance test has the potential human errors or test equipment errors, the self diagnostics has the potential degradation of built-in logics, and the automatic periodic testing has the potential degradation of automatic test facilities. The suggested evaluation models have incorporated the loss or erroneous behaviors of the automatic fault detection methods. The availability and the safety of each module of the safety grade platform have been evaluated as they were applied the automatic periodic test methodology and the fault tolerant evaluation models. The availability and safety of the safety grade platform were improved when applied the automatic periodic testing. Especially the fault tolerant capability of the processor module with a weak self-diagnostics and the process parameter input modules were dramatically improved compared to the conventional cases. In addition, as a result of the safety evaluation of the digital reactor protection system, the system safety of the digital parts was improved about 4 times compared to the conventional cases.

The errors and reducing method in the frequency response function from impact hammer testing (충격햄머 가진으로 구한 주파수응답함수의 오차와 해결방법)

  • 안세진;정의봉
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.71-77
    • /
    • 2002
  • The spectrum of impulse response signal which is obtained from an impulse hammer testing is used for frequency response function, nevertheless it has serious faults when the record length for the signal processing is not very long. The faults cannot be avoided with the conventional signal analyzer that is processing all the signals as if they are always periodic. The signals generated by the impact hammer are undoubtedly non-periodic because of the damping, and are acquired for limited recording time due to the memory as well as the computation performance of the signal analyzer. This paper will make clear the relation between the faults and the length of recording time, and propose the way for solving the faults.

  • PDF

An Enhancement of Multi-Dof Frequency Response Spectrum From Impact Hammer Testing (충격햄머 실험에서 다자유도 주파수 응답스팩트럼의 개선)

  • Ahn, Se-Jin;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.623-629
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF) of the structure. However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the finite record length error and the leakage error. In this paper, the errors in the frequency response function of multi degree of freedom system are formulated theoretically. And the method to remove these errors is also suggested. This method is based on the optimization technique. A numerical example of 3-dof model shows the validity of the proposed method.

  • PDF

The Errors and Reducing Method in 1-dof Frequency Response Function from Impact Hammer Testing (충격햄머 실험에 의한 1자유도 주파수응답함수의 오차와 해결방법)

  • 안세진;정의봉
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.702-708
    • /
    • 2002
  • The spectrum of impulse response signal from an impulse hammer testing is widely used to obtain frequency response function(FRF). However the FRFs obtained from impact hammer testing have not only leakage errors but also finite record length errors when the record length for the signal processing is not sufficiently long. The errors cannot be removed with the conventional signal analyzer which treats the signals as if they are always steady and periodic. Since the response signals generated by the impact hammer are transient and have damping, they are undoubtedly non-periodic. It is inevitable that the signals be acquired for limited recording time, which causes the errors. This paper makes clear the relation between the errors of FRF and the length of recording time. A new method is suggested to reduce the errors of FRF in this paper. Several numerical examples for 1-dof model are carried out to show the property of the errors and the validity of the proposed method.

Development of Reliability Acceptance Sampling Plan for the Exponential Lifetime Distribution under Periodic Inspection and Type I Censoring (수명이 지수분포를 따를 때 정기검사 및 정시종결하에서 신뢰성 샘플링검사계획의 개발)

  • 서순근;김갑석
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.21 no.1
    • /
    • pp.115-129
    • /
    • 1996
  • A reliability Acceptance Sampling Plan (RASP) is developed for testing the exponential mean lifetime under the periodic (i. e., equally-spaced) inspection and Type I censoring. Under the periodic inspection, the exact sampling distribution of maximum likelihood (ML) estimator of mean can not be derived. Hence sample size and acceptance criterion are determined by the algorithm proposed on the basis of Monte Carlo simulation such that the producer's and consumer's risks are satisfied for given censoring time and number of inspections. In addition, the developed RASP is compared in terms of sampling size, OC curve, and expected completion time. The effects for the RASP by the chosen inspection scheme are also discussed.

  • PDF

Hypokalemic periodic paralysis: two different genes responsible for similar clinical manifestations

  • Kim, Hun-Min;Hwang, Hee;Cheong, Hae-Il;Park, Hye-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.11
    • /
    • pp.473-476
    • /
    • 2011
  • Primary hypokalemic periodic paralysis (HOKPP) is an autosomal dominant disorder manifesting as recurrent periodic flaccid paralysis and concomitant hypokalemia. HOKPP is divided into type 1 and type 2 based on the causative gene. Although 2 different ion channels have been identified as the molecular genetic cause of HOKPP, the clinical manifestations between the 2 groups are similar. We report the cases of 2 patients with HOKPP who both presented with typical clinical manifestations, but with mutations in 2 different genes ($CACNA1S$ p.Arg528His and $SCN4A$ p.Arg672His). Despite the similar clinical manifestations, there were differences in the response to acetazolamide treatment between certain genotypes of $SCN4A$ mutations and $CACNA1S$ mutations. We identified p.Arg672His in the $SCN4A$ gene of patient 2 immediately after the first attack through a molecular genetic testing strategy. Molecular genetic diagnosis is important for genetic counseling and selecting preventive treatment.