• 제목/요약/키워드: Performance coefficient

검색결과 4,696건 처리시간 0.029초

Performance Evaluation of the Complex-Coefficient Adaptive Equalizer Using the Hilbert Transform

  • Park, Kyu-Chil;Yoon, Jong Rak
    • Journal of information and communication convergence engineering
    • /
    • 제14권2호
    • /
    • pp.78-83
    • /
    • 2016
  • In underwater acoustic communication, the transmitted signals are severely influenced by the reflections from both the sea surface and the sea bottom. As very large reflection signals from these boundaries cause an inter-symbol interference (ISI) effect, the communication quality worsens. A channel estimation-based equalizer is usually adopted to compensate for the reflected signals under the acoustic communication channel. In this study, a feed-forward equalizer (FFE) with the least mean squares (LMS) algorithm was applied to a quadrature phase-shift keying (QPSK) transmission system. Two different types of equalizers were adopted in the QPSK system, namely a real-coefficient equalizer and a complex-coefficient equalizer. The performance of the complex-coefficient equalizer was better than that of two real-coefficient equalizers. Therefore, a Hilbert transform was applied to the real-coefficient binary phase-shift keying (BPSK) system to obtain a complex-coefficient BPSK system. Consequently, we obtained better results than those of a real-coefficient equalizer.

Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구 (Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change)

  • 황준환;박성영
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

유막의 온도변화를 고려한 플로팅 링 저어널베어링의 성능해석 (An Analysis of Performance of Floating-Ring Journal Bearing Including Thermal Effects)

  • 김종수;최상규;유광택
    • Tribology and Lubricants
    • /
    • 제17권2호
    • /
    • pp.130-137
    • /
    • 2001
  • In this paper, the thermal effects on the performance of floating ring journal bearing are investigated theoretically. The numerical analyses include pressure drop at inner film due to a centrifugal force, fluid momentum effects of supply oil into inner film and thermal effects in lubricating films. All performance data are presented as the rotating speed of journal from 10,000 rpm to 70,000 rpm.

디지털 PID 제어기의 제한 요소 영향 분석(II):유한 단어 길이 문 (Analysis of Limitation Factor Effects on Digital PID Controller(II) : Finite Wordlength Issue)

  • 홍석민;김인중;이상정
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.318-329
    • /
    • 1994
  • This paper deals with the finite wordlength effect on the performance of digital PID controllers. The finite wordlength, one of the major limitation factors in digital controllers, results on two kinds of quantization error : the signal quantization error and the coefficient quantization error. This paper derives the variance of the plant output due to the signal quantization error. Using stability margins as performance criterion, the statistical wordlength concept is adopted for coefficient wordlength selection. Finally, the experimental results exhibit satisfactory performance of the digital PID controller with statistical coefficient wordlength.

Control of a Segway with unknown control coefficient and input constraint

  • Park, Bong Seok
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권2호
    • /
    • pp.140-146
    • /
    • 2016
  • This paper proposes a control method of the Segway with unknown control coefficient and input saturation. To design a simple controller for the Segway with the model uncertainty, the prescribed performance function is used. Furthermore, an auxiliary variable is introduced to deal with unknown time-varying control coefficient and input saturation problem. Due to the auxiliary variable, function approximators are not used in this paper although all model uncertainties are unknown. Thus, the controller can be simple. From the Lyapunov stability theory, it is proved that all errors of the proposed control system remain within the prescribed performance bounds. Finally, the simulation results are presented to demonstrate the performance of the proposed scheme.

공기구동 게이트밸브의 운전 성능평가 방법에 관한 연구 (A Evaluation Method of Operational Performance for Air-operated Gate Valve)

  • 김대웅;박성근;강신철;김양석
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The valve performance has been evaluated from the theoretical equation based on design information such as packing thrust, spring preload and friction coefficient(${\mu}$). The accuracy of those data can be lower than that of vendor's initial design data. Especially, the friction coefficient can be degraded with time than the original condition and the valve performance calculated using the previous friction coefficient can not be available. Accordingly, this paper is describing a new performance evaluation method of valve based on diagnostic test data which are acquired from a site valve tested in static and dynamic conditions. Especially, this paper provides a new method using friction coefficient(${\mu}$) which is derived from the diagnostic test data acquired in the valve's design basis condition.

지중매설관 열교환장치의 성능분석(I) -연속운전실험에서의 온도특성 및 열교환성능- (Performance Analysis of an Earth Tube Heat Exchanger(I) -Temperature Variation Characteristics and Heat Exchange Performance on the Mode of Continuous Operation)

  • 김영복;백이
    • Journal of Biosystems Engineering
    • /
    • 제21권4호
    • /
    • pp.436-448
    • /
    • 1996
  • An earth tube soil air heat exchange system was designed, installed and operated as a single pass heat exchanger to utilize the geothermal energy as an natural energy source. This study was undertaken to investigate the potential of the heating and cooling, energy gain, heat exchange efficiency and coefficient of performance of the system. The system consisted of 30m in length and 30cm in diameter polyethylene pipes buried 2m deep in soil. Maximum heating and cooling performance were 2.51㎾ and 1.26㎾ at the air mass rate of 21cmm. Energy gain and coefficient of performance were the function of temperature difference between outside air and soil temperature. They were expressed as Q=0.33$ imes$$Delta T_{max}$+0.134(㎾) for energy gain and COP=0.44$ imes$$Delta T_{max}$+0.178 for coefficient of performance with correlation factor of 0.95. The mean of heat exchange efficiencies was 85.6%.

  • PDF

국산 트랙터의 성능 변화 (Performance Trend of Korean-made Agricultural Tractors)

  • 김경욱
    • Journal of Biosystems Engineering
    • /
    • 제30권6호통권113호
    • /
    • pp.321-326
    • /
    • 2005
  • Tractor performance was analyzed using the data from 226 Korean-made and 107 imported tractors tested at the National Institute of Agricultural Engineering for the 25-year period from 1980 through 2004. The performance analysis included the specific volumetric fuel consumption (svfc), power per unit weight and traction coefficient evaluated from the viewpoint of PTO power level. No significant performance improvement has been made for the Korean-made tractors over the last 25 years. The average svfc for the maximum PTO power has increased by only $2.1\%$ from 1980 to 2004, resulting in 2.86 kW${\cdot}$h/L in 2004. The average maximum PTO and drawbar power per unit weight of ballasted tractors were 1.38 and 1.19 kW/kN in 2000-2004, indicating $14.0\%$ and $5.9\%$ decreases respectively from 1980 to 2004. The traction coefficient has increased by $23.1\%$ over the 25 years, resulting in 0.68 in the 2000-2004 period. Poor performance improvement was also observed from the imported tractors. In the 2000-2004 period, average svfc for the maximum PTO power, PTO power per unit ballasted weight, drawbar power per unit ballasted weight and traction coefficient of the imported tractors were respectively 3.0 kW${\cdot}$h/L, 1.34 kW/kN, 1.13 kW/kN and 0.68. PTO and drawbar power per unit weight were lower in imported tractors than the Korean-made tractors. Comparing the test results with those of tractors less than 37 kW tested at the Nebraska Tractor Test Laboratory from 1981 to 2002, the Korean-made tractors have exhibited better performance in terms of power per unit weight. However, poor performance in the svfc and traction coefficient was observed. The average svfc and traction coefficient of the Korean-made tractors were respectively $86.4\%$ and $83.7\%$ of the tractors tested at the NTTL over the same period.

양서류 울음 소리 식별을 위한 특징 벡터 및 인식 알고리즘 성능 분석 (Performance assessments of feature vectors and classification algorithms for amphibian sound classification)

  • 박상욱;고경득;고한석
    • 한국음향학회지
    • /
    • 제36권6호
    • /
    • pp.401-406
    • /
    • 2017
  • 본 논문에서는 양서류 울음소리를 통한 종 인식 시스템 개발을 위해, 음향 신호 분석에서 활용되는 주요 알고리즘의 인식 성능을 평가했다. 먼저, 멸종위기 종을 포함하여 총 9 종의 양서류를 선정하여, 각 종별 울음소리를 야생에서 녹음하여 실험 데이터를 구축했다. 성능평가를 위해, MFCC(Mel Frequency Cepstral Coefficient), RCGCC(Robust Compressive Gammachirp filterbank Cepstral Coefficient), SPCC(Subspace Projection Cepstral Coefficient)의 세 특징벡터와 GMM(Gaussian Mixture Model), SVM(Support Vector Machine), DBN-DNN(Deep Belief Network - Deep Neural Network)의 세 인식기가 고려됐다. 추가적으로, 화자 인식에 널리 사용되는 i-vector를 이용한 인식 실험도 수행했다. 인식 실험 결과, SPCC-SVM의 경우 98.81 %로 가장 높은 인식률을 확인 할 수 있었으며, 다른 알고리즘에서도 90 %에 가까운 인식률을 확인했다.

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구 (A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window)

  • 이장범
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.