• Title/Summary/Keyword: Performance based standard

Search Result 2,658, Processing Time 0.023 seconds

A Fundamental Study on the Application of Performance-Based Construction Standard in Building Construction (건축분야에서의 성능중심 건설기준 적용 방안에 관한 기초적 연구 - 시방서를 중심으로 -)

  • Roh, Tae-Im;Kim, Sang-Heon;Ji, Suk-Won;Choi, Soo-Kyung;Seo, Chee-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.187-191
    • /
    • 2008
  • This study focuses on applying performance-based design to construction standard in building construction. First, it realizes situation and issues of standard specification in building construction, deduces the need factors for establishing performance-based construction standard, and then, it proposes the application of performance standard. The required stages for deducing performance-based construction standard consist of dividing building parts, deducing required functions, performance items and performance requirement and deciding a method of performance evaluation. Through these stages, performance-based design process is deduced.

  • PDF

The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit- (예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로-)

  • 윤용운
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

Nursing Students' Awareness and Performance on Standard Precautions of Infection Control in the Hospital (간호대학생의 병원감염관리 표준주의에 대한 인지도와 수행도)

  • Hong, Sun-Yung;Kwon, Young-Sook;Park, Hee-Ok
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.2
    • /
    • pp.293-302
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate nursing students' awareness and performance on standard precautions and to provide meaningful information for nursing students' education regarding hospital infection control. Method: Four hundred forty seven nursing students at 6 universities in D-city participated in this study. Data collection was conducted from March to April 2011. Students' awareness and performance on standard precautions of infection control in hospitals were measured using the modified 2007 CDC standard precautions guidelines. Data analysis was performed using the SPSS WIN 18.0 program, descriptive statistics, t-test, and ANOVA. Results: The level of students' awareness in the standard precautions was higher than performance. The higher levels of students' awareness and performance on standard precautions included patient care equipment, safe injection practices, and worker safety. The lower levels of students' awareness and performance on standard precautions included hand hygiene and personal protective equipment. There was no difference in the students' awareness and performance of standard precautions according to their characteristics. Conclusions: Based on the findings of this study, hand hygiene and personal protective equipment need to be stressed more within the program to improve nursing students' infection control techniques.

Study on the Development of Standard Reference Materials for Safety Control of Construction Materials (건설재료의 안전적 제어를 위한 표준물질 (Standard Reference Materials) 도출)

  • Lee, Dong Kyu;Lee, Keon Woo;Choi, Myoung Sung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.54-61
    • /
    • 2017
  • The purpose of this study is to develop standard reference materials for safety control of construction materials considering the required performance of standard materials including flow performance incorporating particles. The flow characteristics of concrete are very complicated depending on mixing proportions of constituent materials, admixtures, amount of mixing, type of mixer, time of mixing, temperature and so forth. Uncertainties and multidimensional properties of concrete have been evaluated through various studies but there are few researches for the development of standard reference material. In this study, based on the rheological concept, the flow performance of construction materials was evaluated to understand the properties of standard reference materials and was finally obtained representing materials which simulate the standard reference materials.

Measuring and Reporting Corporate Social Performance: An Exploratory Study for Practical Application of Double Bottom Line (기업의 사회적 성과 측정과 보고: 더블바텀라인의 실무 적용을 위한 탐색적 연구)

  • Jo, Illhyung
    • Knowledge Management Research
    • /
    • v.21 no.2
    • /
    • pp.1-19
    • /
    • 2020
  • The purpose of this study is to suggest a practical way to measure and report corporate social performance as public interest in corporate social value pursuits increases. In particular, we will look for ways to measure and report on the financial and social performance of a company based on the concept of the Double Bottom Line (DBL), which has recently spread to big companies. For this purpose, this study analyzed the theoretical background and practical techniques related to measuring and reporting corporate social performance, and examined methods for measuring and reporting social performance in the existing financial performance measurement system. As a result, SROI was the most suitable method for measuring social performance of a company. It is recommended that social performance reporting follows the disclosure method of the accounting system, and the details of reporting suggest that using the standard of GRI Standard, an international standard related to sustainability reporting, is the most reasonable alternative to 'Double Bottom Line' performance reporting.

An Implementation and Performance Test of Automotive RTOS Based on OSEK/VDX (OSEK/VDX 기반 차량용 RTOS의 구현과 성능 테스트)

  • Cho, Sung-Rae;Kim, Byung-Joon;Jin, Sung-Ho;Lee, Jun-Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.3
    • /
    • pp.139-148
    • /
    • 2011
  • As the architecture of automotive software is complicated and LOC of software increases, there is an increasing demand for standard operating system. OSEK/VDX defines an industry standard for automotive operating system and middleware. This paper introduces an implementation of RTOS(OSCAR-OSEK) based on OSEK/VDX standard. For better speed of scheduling, we suggest a new method for ready queue implementation considering the characteristic of automotive application software. Also we introduce a method for improving the portability of RTOS on various MCUs. And, we show OSCAR-OSEK implementation and performance test results.

The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance (에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구)

  • Yun, Hiwon;Ryu, Hyung Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

Performance Based Fire Engineering in Japan

  • Kohno, Mamoru;Okazaki, Tomohito
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • This paper explains the Japanese present situations relevant to the fire resistance performance. Performance-based fire provisions was introduced in 1998 for the first time when the Building Standard Law was amended. However, performance-based fire resistance design had been used since long before the official introduction of performance-based provisions. A Comprehensive Technology Development Project of Ministry of Construction from 1982 to 1986 established a technical basis for performance-based fire safety engineering in Japan. A system of calculation methods for fire resistance verification was prescribed in the Ministry Notification in 2000 utilizing the results of this project as a background. This method, referred to as the Fire Resistance Verification Method (FRVM), is the standard method to verify the fire resistance performance of principal building parts such as columns, beams, and walls of steel, concrete, or wood structured buildings. For tall buildings, however, more advanced method for performance verification is often necessary because new building materials or structural systems are often used for these buildings. An example project of tall building owned by a major newspaper company is presented in this paper. Advanced thermal deformation analysis is executed to secure the fire resistance of the building.

Video Coding Algorithm Based on High Efficiency Video Coding (HEVC) and Hybrid Transforms

  • Wang, Chengyou;Shan, Rongyang;Zhou, Xiao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4448-4466
    • /
    • 2018
  • In recent years, due to its high efficiency and better performance, the high efficiency video coding (HEVC) has become the most common compression standard in the field of video coding. In this paper, the framework of HEVC is deeply analyzed, and an improved HEVC video coding algorithm based on all phase biorthogonal transform (APBT) is proposed, where APBT is utilized to replace the discrete cosine transform (DCT) and discrete sine transform (DST) in original HEVC standard. Based on the relationship between APBT and DCT, the integer APBT is deduced. To further improve the coding performance, an optimal HEVC video coding algorithm based on hybrid APBT is proposed. The coding performance of the proposed HEVC coding algorithm is improved without increasing the complexity. Experimental results show that compared with HEVC standard algorithm, the improved HEVC video coding algorithm based on hybrid APBT can improve the coding performance of chrominance components by about 0.3%.

A Study on Domestic Standard Parameter Setting for BIM-based Energy Performance Evaluation - Focused on Possession Area per Person of Occupants in Government Offices - (BIM 기반 에너지성능평가를 위한 국내 표준 매개변수 설정 방안에 대한 연구 - 공공청사 업무시설의 재실자 1인당 점유면적을 중심으로 -)

  • Lee, Yun-Jeong;Lee, Kweon-Hyoung;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-21
    • /
    • 2015
  • Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.