• Title/Summary/Keyword: Performance Evaluations

Search Result 887, Processing Time 0.031 seconds

A Non-Uniform Convergence Tolerance Scheme for Enhancing the Branch-and-Bound Method (비균일 수렴허용오차 방법을 이용한 분지한계법 개선에 관한 연구)

  • Jung, Sang-Jin;Chen, Xi;Choi, Gyung-Hyun;Choi, Dong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.361-371
    • /
    • 2012
  • In order to improve the efficiency of the branch-and-bound method for mixed-discrete nonlinear programming, a nonuniform convergence tolerance scheme is proposed for the continuous subproblem optimizations. The suggested scheme assigns the convergence tolerances for each continuous subproblem optimization according to the maximum constraint violation obtained from the first iteration of each subproblem optimization in order to reduce the total number of function evaluations needed to reach the discrete optimal solution. The proposed tolerance scheme is integrated with five branching order options. The comparative performance test results using the ten combinations of the five branching orders and two convergence tolerance schemes show that the suggested non-uniform convergence tolerance scheme is obviously superior to the uniform one. The results also show that the branching order option using the minimum clearance difference method performed best among the five branching order options. Therefore, we recommend using the "minimum clearance difference method" for branching and the "non-uniform convergence tolerance scheme" for solving discrete optimization problems.

Voice Quality in Patients with Asthma (천식환자에서의 음성의 질)

  • Han, Myung-Woul;Kim, Seong-Tae;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.63-67
    • /
    • 2009
  • Background and Objectives: In patients with asthma, increased obstruction and resistance of airway result in impairment in the generation of voice. Allergy and nasal polyposis, which are frequently observed in patients with asthma, are other factors that affect the vocal performance. Bronchodilators and steroids are commonly used in the treatment of asthma, and these agents also have been reported to be associated with voice changes. The aim of this study is to evaluate the voice quality in patients with mild to-moderate asthma by subjective and objective methods. Materials and Methods: A total of 36 patients with asthma established in the Department of Respiratory Medicine were included in this study. 23 were women and 13 were men, with a mean age of 51.7 years. The average duration of asthma was 77.0 months. All patients had mild-to moderate asthma. Acoustic and aerodynamic analyses were performed and the movements of the vocal cords were examined by videolaryngostroboscopy (VLS). Voice Handicap Index (VHI) and GRABS scales were used for subjective evaluations. Results: 50% of patients suffered from dysphonia and FO was 119.3${\pm}$23.7 Hz in male and 198.2${\pm}$18.4 Hz in female patients. There were no significant differences in average shimmer and NHR between females (4.90${\pm}$2.95% ; 0.1O${\pm}$0.04 dB) and males (4.64${\pm}$2.45% ; 0.20${\pm}$0.15 dB). However, the value of jitter was greater for females (2.60${\pm}$1.92%) than for males (1.21${\pm}$0.84%). The VHI score was above the normal limit in 35%, and VLS findings were shown diverse abnormality in 89% asthmatics from mucosal change to hyperfunction of supragottis and contact granuloma. But duration of illness and steroid dose did not correlate with these findings. Conclusion: Subjective and objective abnormality was shown in more than 50% of asthmatic patients. We suggest that persons who suffer from asthma should be examined for possible voice disorders by laryngologist. Additionally, appropriate medical care and voice therapy should be provided for those who have voice disorders associated with asthma.

  • PDF

Future Directions for Education of Social Welfare Administration: Training Students as Managers in Social Service Agencies (한국 사회복지 행정교육의 발전방향 : 사회복지 기관관리자 양성을 중심으로)

  • Choi, Youseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2573-2584
    • /
    • 2015
  • The purpose of this study is to identify increasing needs for training students as managers in social service agencies and to suggest ways to develop the education of social welfare administration. Agency evaluations and performance management has increased demands for effectiveness and accountability of social service agencies, which also has increased the roles of managers in social service agencies. Using 'Korean Social Worker Survey' conducted by Korean Association of Social Workers, this study examines job characteristics of 2,479 social workers. The results show that administration/management activities take about 40% of social workers' daily activities. Community organization, human resource management, and planning/financial management are regarded as more important and difficult than other tasks. However, sufficient education for preparing students as social service managers is not provided in undergraduate and graduate level of college education. In addition, social workers make their life long careers as managers. Thus, the education of social welfare administration needs to refocus on the provision of knowledge and skills required for competent social service managers. This study suggests future directions for developing education of social welfare administration in undergraduate and graduate level of college education including field practice.

Experimental Study of the Heat Transfer Rate of the Plate Fin-Tube Condenser for a Household Refrigerator (냉장고용 판형 핀-관 응축기의 열전달 성능에 관한 실험적 연구)

  • Son, Young-Woo;Lee, Jang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4802-4808
    • /
    • 2014
  • A plate-fin tube type heat exchanger has a lighter weight, approximately 30%, than the conventional circular-fin type condenser of household refrigerator. Because the low weight means low cost, it can have significant effects on the growth of related businesses if similar performance can be guaranteed. To check the possibility of the use of such a plate fin-tube condenser, experimental evaluations were performed in this study. Four different condensers including a conventional circular fin-tube condenser were used for the test. A well designed refrigerant supply system was used to supply similar conditions with a refrigerator, and the heat transfer rate and pressure drops of air side were measured precisely. As a result, the plate fin-tube type condensers showed a lower heat transfer rate of more than 13% than the conventional circular fin-tube type condenser, but the air side pressure drop was reduced and the heat transfer per unit weight was increased. Therefore, it shows the possibility of the use of a plate fin-tube type condenser after optimizing the air flow path and increasing the air flow to make a similar heat transfer rate.

The Development of Scrubber for F-gas Reduction from Electronic Industry Using Pressure Swing Adsorption Method and Porous Media Combustion Method (압력순환흡착법과 다공성 매체 연소법을 이용한 전자산업 불화가스 저감 스크러버 개발)

  • Chung, Jong Kook;Lee, Ki Yong;Lee, Sang Gon;Lee, Eun Mi;Mo, Sun Hee;Lee, Dae Keun;Kim, Seung Gon
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.181-187
    • /
    • 2017
  • The perfluorocompounds (PFCs) emitted from the semiconductor and display manufacture is treated by abatement systems which use various technologies, such as combustion, thermal, plasma, catalyst. However, it is required that the system should overcome their drawbacks with excess energy consumption and low removal efficiency. The new technology using combination of pressure swing adsorption and excess enthalpy combustion for the reduction of PFCs emissions were developed and analyzed its characteristics. PFCs concentration ratio and PFCs loss factor were calculated from measuring concentration of PFCs at the calculated by comparing concentration of PFCs at the combustor's inlet and outlet. There were performance evaluations with various gas flow for comparing energy consumption and removal efficiency with existing equipments. The concentration ratio and the loss factor of PFCs were 1.65, 8.2%, respectively, when the total gas flow of the pressure swing absorption (PSA) inlet was 204 liter per minute (LPM) and $CF_4$ concentration was 1412 ppm. In comparison with existing system at constant condition, $CF_4$ removal efficiency for a porous media combustion (PMC) showed the improvement more than 16% and the consumed energy was also reduced up to approximately 41%. Then, the total gas flow introduced into PMC and $CF_4$ concentration were 91-LPM and 2335 ppm, respectively, and the destruction and removal efficiency of $CF_4$ was about 96% at 19-LPM $CH_4$, and 40-LPM $O_2$.

Evaluations on the Compaction Energy Effects on the Soil Compaction at Sub-Zero Temperature (영하에서의 다짐에너지에 따른 다짐 효과 평가)

  • Lee, Jeonghyeop;Hwang, Bumsik;Chae, Deokho;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.13-20
    • /
    • 2015
  • Due to the population growth and exhaustion of resource, the development on the harsh environment such as cold weather is emerging as an alternative for new resource development. The permafrost area covers about 14 percent of the world's land area and the global construction market for such area is rapidly expanded. Whereas the developed countries have already recognition of the need for research of coldest place and invested heavily in technology development, the domestic technology for the coldest place development is less developed and related research has rarely been performed. There is not a detailed national specification standard for the strength and deformation properties of the earthworks at sub-zero temperature but simple field directions. Therefore, the D compaction tests were conducted on the sand with fine contents of 0%, 5%, 10% and 15% at room temperature ($18^{\circ}C$), $-3^{\circ}C$ and $-8^{\circ}C$ to investigate the effect of the compaction energy on the compacted soils at sub-zero temperatures. Based on the test results, the larger compaction energy, the larger maximum dry unit weight under sub-zero temperature and D type compaction at $-3^{\circ}C$ show similar max. dry unit weights as those obtained from the compaction at the room temperature. However, compaction at $-8^{\circ}C$ showed significant performance degradation regardless of the compaction energy.

Improving the Efficiency of DMAIC Application Process through the Case Studies of Practical Six Sigma Construction Projects (6시그마 건설실무 적용사례 분석을 통한 DMAIC 적용 프로세스의 효율성 제고)

  • Kwon, O-Bin;Lee, Seung-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.1
    • /
    • pp.88-100
    • /
    • 2010
  • As the competition between companies are deepened, the number of companies adopting six sigma principles, which is one of the innovative management strategies, are increasing. According to this trend, the changes in both strategies and methodologies of six sigma are continuous. However, the evaluations and the management principles included in the process after the six sigma applications are insufficient, and the cooperation between the parties in the company is also not enough because the application process of six sigma is too complex and not efficient. In order to solve this problem, a research for developing the methodology which can learn about and do six sigma applications is so necessary, specifically for expanding the six sigma applications and introducing the participation of all company members. The purpose of this study, therefore, was to develop and present more efficient Six Sigma applied process by reducing the existing unnecessary steps in improvement one, by applying the examination method of wasteful elements on the potential factors, through analyzing the Six Sigma DMAIC applied case in the construction industry. The result of those application showed that the detection of potential factors using wasting elements was possible in measurement step and that it was possible for the improved process with reduced steps compared to existing process while to remain the outcomes. It is considered that the performance rate of Six Sigma project will be improved significantly because the reduction in the improvement step does not affect the improvement effect within the whole Six Sigma project.

Nonlinear Conte-Zbilut-Federici (CZF) Method of Computing LF/HF Ratio: A More Reliable Index of Changes in Heart Rate Variability

  • Vernon Bond, Jr;Curry, Bryan H;Kumar, Krishna;Pemminati, Sudhakar;Gorantla, Vasavi R;Kadur, Kishan;Millis, Richard M
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.207-212
    • /
    • 2016
  • Objectives: Acupuncture treatments are safe and effective for a wide variety of diseases involving autonomic dysregulation. Heart rate variability (HRV) is a noninvasive method for assessing sympathovagal balance. The low frequency/high frequency (LF/HF) spectral power ratio is an index of sympathovagal influence on heart rate and of cardiovascular health. This study tests the hypothesis that from rest to 30% to 50% of peak oxygen consumption, the nonlinear Conte-Zbilut-Federici (CZF) method of computing the LF/HF ratio is a more reliable index of changes in the HRV than linear methods are. Methods: The subjects of this study were 10 healthy young adults. Electrocardiogram RR intervals were measured during 6-minute periods of rest and aerobic exercise on a cycle ergometer at 30% and 50% of peak oxygen consumption ($VO_{2peak}$). Results: The frequency domain CZF computations of the LF/HF ratio and the time domain computations of the standard deviation of normal-to-normal intervals (SDNN) decreased sequentially from rest to 30% $VO_{2peak}$ (P < 0.001) to 50% $VO_{2peak}$ (P < 0.05). The SDNN and the CZF computations of the LF/HF ratio were positively correlated (Pearson's r = 0.75, P < 0.001). fast Fourier transform (FFT), autoregressive (AR) and Lomb periodogram computations of the LF/HF ratio increased only from rest to 50% $VO_{2peak}$. Conclusion: Computations of the LF/HF ratio by using the nonlinear CZF method appear to be more sensitive to changes in physical activity than computations of the LF/HF ratio by using linear methods. Future studies should determine whether the CZF computation of the LF/HF ratio improves evaluations of pharmacopuncture and other treatment modalities.

Power Allocation Scheme For Mobile Communication Systems Using Directional Transmission (방향성 전송을 사용하는 이동통신 시스템을 고려한 파워 할당 방안)

  • Lee, Woongsup;Jung, Bang Chul;Ban, Tae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2621-2627
    • /
    • 2014
  • Directional transmission is one of key technology to solve the utmost problem that current mobile communication system faces, which is explosively increasing data traffic, since directional transmission can maximize the throughput of mobile communication systems. In this work, we consider power allocation scheme for mobile communication system which utilizing directional transmission. Especially, we consider the case in which multiple users in the same sector of base station, are served at the same time by utilizing directional transmission. For this scenarios, we consider equal power allocation scheme, Water-filling based scheme and inverse SNR scheme. Moreover, we propose beam power allocation scheme whose objective is to maximize overall system throughput by taking into account interference between different directional transmissions. Moreover, we have examined the spectral efficiency and Jain's fairness index of various power allocation schemes for directional transmission by using system level simulator that has been developed in our previous work. Through simulations, it has been verified that the proposed power allocation scheme can improve the spectral efficiency of the system by 28%.

Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator (토네이도 블록형 선회류 침사제거기의 침사제거효율 평가)

  • Kim, Jong-Je;Lee, Bum-Soo;Yeom, Cheol-Min;Lim, Hee-Jae;Jung, Seok-Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.