• Title/Summary/Keyword: Perfomance analysis

Search Result 44, Processing Time 0.025 seconds

A Study on the Perfomance Analysis of Low Energy Cooling Systems in Office building (사무소건물의 에너지절약형 냉방시스템 성능분석에 관한 연구)

  • Park, Chang-Bong;Rhee, Eon-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.89-94
    • /
    • 2010
  • A large portion of the energy cost of a building is cooling and heating to maintain a comfortable indoor environment. Air conditioning is now one of the important parts in the building design, as increase in energy consumption and pollutant emission in energy conversion process. In this study, elements that affects the energy consumption of model building are identified and the perfomance analysis of the alternative a Low Energy Cooling Systems considering characteristics of model building and energy saving performance is analyzed. In this study, elements that affect the energy consumption of office building are identified and energy saving performance of the alternative air conditioning system is analyzed. As a result, applied to earn and suggest basic data for energy saving measures. In this study, EnergyPlus simulation program was used to evaluate the energy load when alternative Low Energy Cooling Systems are applied to the model building. The reliability of simulation program is verified by comparing actual energy load from operation data of building management office and predicted energy load using simulation program. For Low Energy Cooling System application which considers the purpose and characteristics of the building, reasonable and energy-saving air conditioning method obtained by analyzing energy consumption elements for each expected air conditioning methods is used to deduct result of this study.

Perfomance Analysis of SRM according to Design Parameters (SRM의 설계파라메터 변화에 따른 성능해석)

  • Kim, Tae-Hyoung;Moon, Jae-Won;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.18-20
    • /
    • 2003
  • In this paper, design and performance analysis of switched reluctance motor(SRM) according to design parameters are foaled. The parameters which are sensitive to the performance are examined and selected to have a good performances. Prototype machines are constructed to compare with the simulated results.

  • PDF

A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System" (주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ))

  • Lee, Sung-Ok;Kim, Soo-Am;Shin, Sung-Eun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

Development of Kernel based High Speed Packet Filtering Imbedded Gateway and Firewall Using Cloud Database (클라우드 데이터베이스를 이용한 커널 기반 고속 패킷필터링 임베디드 게이트웨이 및 방화벽 개발)

  • Park, Daeseung;Kim, Soomin;Yoo, Hanseob;Moon, Songchul
    • Journal of Service Research and Studies
    • /
    • v.5 no.1
    • /
    • pp.57-70
    • /
    • 2015
  • This paper develop curnel based high speed packet filtering imbedded gateway and firewall using cloud database. This study develop equipment include of predict function through bigdata analysis using cloud system. This equipment include intrusion prevention for network attack, and include system security function of L7 switch based contents. This study can improve security level of little company and general family. This study can pioneer a new market. This study can develop high perfomance switch and replacement of existing security equipment. This study proposed new next generation algorithm for constuction of high performance system from low specifications.

A New Pattern Classification and the Analysis of the Lung Sound by Using Cepstrum (Cepstrum을 이용한 폐음의 분석 및 패턴 분류)

  • 김종원;김성환
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.159-166
    • /
    • 1994
  • A new pattern classification algorithm using cepstrum to analyze lung sounds for the classification of pattern with pulmonary and bronchial disorders is proposed. To evaluate the perfomance of the proposed method, the results are compared to the pattern classification with the AR modeling method. In the experiment lung sounds recorded for the training of physician used. As a results, the accuracy of the cepstrum classification is 92.3 % and AR modeling is the 53.8 %, therefore cepstrum modeling method has very high performance than AR and it turned out to be a very efficient algorithm.

  • PDF

Seismic Perfomance Evaluation of Wind-Designed Steel Highrise Buildings Based on Linear Dynamic Analysis (내풍설계된 철골조 초고층건물의 선형동적해석에 의한 내진성능평가)

  • Lee Cheol-Ho;Kim Seon-Woong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.652-659
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall building, the probable structural impact of the design basis earthquake or the maximum credible earthquake on the selected structural system should be considered at least in finalizing the design. In this study, by using response spectrum analysis and linear time history analysis method, seismic performance evaluation was conducted for wind-designed concentrically braced steel highrise buildings. Both spectrum-compatible artificial accelerograms and recorded accelerograms were used as input ground motions for the time history analysis. The analysis results showed that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seismic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. Time history analysis results generally tended to underestimate the seismic response as compared to those of response spectrum analysis.

  • PDF

Seismic Perfomance Evaluation of Wind-Designed Steel Highrise Buildings Based on Linear Dynamic Analysis (내풍설계된 철골조 초고층건물의 선형동적해석에 의한 내진성능평가)

  • Lee, Cheol-Ho;Kim, Seon-Woong
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.177-184
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall building, the probable structural impact of the design basis earthquake or the maximum credible earthquake on the selected structural system should be considered at least in finalizing the design. In this study, by using response spectrum analysis and time history analysis method, seismic performance evaluation was conducted for wind-designed concentrically braced steel highrise buildings. Input ensemble was normalized to be compatible with expected peak ground acceleration. The analysis results showed that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seismic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The time history analysis tended to significantly underestimated the seismic response as compared to response spectrum analysis. Further detailed studies regarding selection and scaling scheme of input ground motions is needed.

  • PDF

Sensitivity Analysis of Shape Design Parameters of a Toque Converter Using Potential Flow (포텐셜 유동 해석을 이용한 토크 컨버터의 형상설계 파라미터들의 민감도 해석)

  • 김준양;이장무;박찬일;임원식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.924-929
    • /
    • 1994
  • In using a performance model of a torque converter determined by its gemetric condition, it is possible that the analysis of two arbitrary converters produces the the same results because of the same value of equivalent parameters despite their different shapes. Therefore, it is necessary to understand the effect of shape factor on dynamic perfomance, and equivalent parameters reoresenting a performace model of a converter should into its defined by the behavior of flow field. In this study, torus flow of a torque converter is changed into its equivalent system defined by the behavior of flow, and govering equations for the system are presented and used for analysis. Equivalent parameters are obtained from the results of flow analysis and are compared with parameters of one dimensional performance model. The influence that shape change of a converter has on the behavior of flow and the equivalent parameters is studied qualitatively.

  • PDF

Performance Characteristic Anaysis of Micro Hydropower Sites (Micro급 수력발전입지의 성능특성 분석)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.498-501
    • /
    • 2012
  • A methodology to evaluate the performance analysis for micro hydropower sites has been studied. It consists of two main parts; flow duration function which can describe micro hydropower sites and performance analysis to estimate the output characteristics of micro hydropower plants. The output performance characteristics for Magok stream was analyzed, using developed model. Also, primary design specifications such as design flowrate, installed capacity, operational rate and annual electricity production were estimated and dicussed. Additionally, it was found that the developed model in this study is useful tool to estimate feasibility assessment for micro hydropower sites.

  • PDF

On the investigation of structural behaviour of nuclear containment building wall element using microscopic material model (미시적 재료모델을 사용한 원전 격납건물 벽체 요소의 구조거동 분석)

  • 이상진;이홍표;서정문
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.217-221
    • /
    • 2000
  • Nonlinear stress analysis of nuclear containment building wall element is carried out using microscopic material model. The present study mainly focuses on the finite element analysis of the nuclear containment building wall element under biaxial tensile stresses and it evaluates the perfomance of adopted microscopic material model in the membrane energy dominant situation. From the numerical analysis, the adopted material model peforms well and has a good agreement with experiment result. Finally, the result of present study can be severed as a benchmark test when concrete material model is in need of evaluation.

  • PDF