• Title/Summary/Keyword: Peak operation

Search Result 812, Processing Time 0.029 seconds

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

A Study the load Forecasting Techniques using load Composition Rates (Residential load) (부하구성비를 이용한 부하예측에 관한 연구 - 주거용 부하를 중심으로 한)

  • Park, Jun-Yioul;Lim, Jae-Yun;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.82-85
    • /
    • 1993
  • The load forecasting has been essential in planning and operation of power systems. The load composition rata is also needed to analyze power-systems - load flow calculation and system stability. This paper proposes the monthly peak load forecasting methods for load groups in residential class using load composition rate and electric consumption characteristics. The proposed methods were applied to a real-scale power system and the effectiveness was turned out.

  • PDF

Filter Design for Noise Suppression in IVP signals of a Korean-type Total Artificial Heart

  • Om, K.S.;Choi, W.W.;Ahn, J.M.;Cho, Y.H.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.268-272
    • /
    • 1996
  • The removal of impulsive noise terms which occur in interventricular pressure (IVP) signals of a Korean-type total artificial heart is essential for estimation of atrial pressure change. We compared various order statistic filters and conclude that median filter with sidelength L = 1 is the most appropriate filter for IVP signals in the perspectives of operation cost, detail preserving (peak value), and waveform.

  • PDF

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

Study on the Economic Analysis for Non-Prediction Algorithm with the Energy Storage System (에너지저장장치 도입 시 비예측 알고리즘의 경제성 분석에 관한 연구)

  • Hong, Jong-Seok;Kang, Byoung-Wook;Chai, Hui-Seok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.94-99
    • /
    • 2015
  • Prediction algorithm of the energy storage system in accordance with the load pattern can cause economic loss in case of a failure prediction. In addition, algorithm that uses TOU(Time of Use) based on the revelation by the power electric charge which covers most simply is an inefficient operation because it is only for the purpose of reducing the peak power. In this paper, we introduced a non-prediction algorithm with a conventional TOU in order to solve this problem operating the energy storage system economic and efficient.

Development of a 0.5MW PCS for efficient connection operation of wind power system (풍력 발전시스템의 효율적인 연계운전을 위한 0.5MW급 PCS 개발)

  • Lee, Yun-Jae;Choi, Eun-Sik;Lee, Chung-Woo;Ryu, Kang-Yeul;Jo, Jang-Ho;Lee, Jin
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.498-500
    • /
    • 2012
  • According to the climatic characteristics of the wind power output is difficult to predict and a severe strain due to a change in output has been very influential in the grid. Jeju Hangwon wind farm, many of the wind generator is installed in a wide area because it is not have this device that artificially Smoothing is needed. In addition, By the requirements of the power company active power supply / control and improve power system reliability and energy storage during the peak demand for electricity using the energy stored in the power supply is needed. In this paper, Unit 12 in Jeju Hangwon demonstrated 0.5MW PCS and energy storage system associated with the wind through the stabilization of output and the leveling of output and test results will be introduced.

  • PDF

The Operation and Monitoring of PV System with Peak-Cut Function (피크컷 기능을 가지는 태양광 시스템의 동작 및 모니터링)

  • Han, Donghwa;Lee, Y.G.;Ban, C.H.;Chun, T.W.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.120-121
    • /
    • 2012
  • 화석연료의 고갈로 인하여 신재생에너지의 중요성이 부각되고 있는 현재, 신재생에너지가 부각되고 있다. 본 논문에서는 신재생에너지원중 큰부분을 차지하는 태양광에서 발전되는 에너지를 효율적으로 사용하기 위함을 목적으로 한다. 기존의 태양광 시스템에 배터리를 이용하여 에너지를 저장하여 부하의 수요가 클 경우 배터리의 에너지를 방전하여 전체수요의 최대 전력을 삭감하고자 한다. 이를 위한 알고리즘, 실험, 모니터링을 통하여 이를 입증하고자 한다.

  • PDF

KPX Operating Study Summer 2007 (2007년도 하절기 전력계통 운영방안)

  • Hwang, Bong-Hwan;Shin, Yong-Son;Cho, Jong-Man;Song, Seok-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.427-428
    • /
    • 2007
  • This paper presents a study for the Korea power system at yearly peak load time in 2007 summer period. The power system become more complex due to the gradual increment of power demand. We analyze various problems in power system operation, by the use of PSS/E(power flow, fault and transient stability study) and VSAT for voltage stability. The results of power system operating plans and countermeasures are described.

  • PDF

Practical Applications of Reactive Power and Voltage Planning In Korea Power System (우리나라 계통에서의 무효전력 수급현황 및 전압특성 분석)

  • Lee, Joo-Ho;Jung, Eung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.158-161
    • /
    • 2004
  • This paper presents practical applications of reactive power and voltage planning to obtain voltage stability and operational voltage level for 2005 year summer peak Korea power system. It also describes the new electric facilities, operation criteria, voltage levels, MVAr flows, reactive power reserves in each control area. And reactive compensation devices are installed to maintain established voltage levels and stability margins. This simulation results show the improvement of voltage levels and the increase of reactive margins & interface flow margins. Finally, the paper reports the necessity of dynamic reactive reserves. It can be applied to analysis reactive compensation requirements and P-V & V-Q curves by PSS/E & VSAT.

  • PDF

The Analysis of Faults for the Excitation System of Generator (발전기 여자시스템의 에러 해석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Paik, Doo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1047-1049
    • /
    • 2005
  • Hydraulic power plant is operated for peak load and frequently start-stop because of no continuous operation. So the fault can happen due to field voltage swing in the middle of starting or reactive power swing on the line. On this research, we want to analyze that this status influence on line and generator. we hope this research can contribute to the power quality improvement.

  • PDF