• Title/Summary/Keyword: Peak airway pressure

Search Result 33, Processing Time 0.019 seconds

Airway Reactivity to Bronchoconstrictor and Bronchodilator: Assessment Using Thin-Section and Volumetric Three-Dimensional CT

  • Boo-Kyung Han;Jung-Gi Im;Hak Soo Kim;Jin Mo Koo;Hong Dae Kim;Kyung Mo Yeon
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.127-134
    • /
    • 2000
  • Objective: To determine the extent to which thin-section and volumetric three-dimensional CT can depict airway reactivity to bronchostimulator, and to assess the effect of different airway sizes on the degree of reactivity. Materials and Methods: In eight dogs, thin-section CT scans were obtained before and after the administration of methacholine and ventolin. Cross-sectional areas of bronchi at multiple levels, as shown by axial CT, proximal airway volume as revealed by three-dimensional imaging, and peak airway pressure were measured. The significance of airway change induced by methacholine and ventolin, expressed by percentage changes in cross-sectional area, proximal airway volume, and peak airway pressure was statistically evaluated, as was correlation between the degree of airway reactivity and the area of airways. Results: Cross-sectional areas of the bronchi decreased significantly after the administration of methacholine, and scans obtained after a delay of 5 minutes showed that normalization was insufficient. Ventolin induced a significant increase in cross-sectional areas and an increase in proximal airway volume, while the effect of methacholine on the latter was the opposite. Peak airway pressure increased after the administration of methacholine, and after a 5-minute delay its level was near that of the control state. Ventolin, however, induced no significant decrease. The degree of airway reactivity did not correlate with airway size. Conclusion: Thin-section and volumetric spiral CT with three-dimensional reconstruction can demonstrate airway reactivity to bronchostimulator. The degree of reactivity did not correlate with airway size.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF

Comparative Analysis of Tidal Volume and Airway Pressure with a Bag-valve Mask using RespiTrainer (RespiTrainer를 활용한 백-밸브마스크 환기에서 일회호흡량과 기도압 비교 연구)

  • Shin, So-Yeon;Lee, Jae-Gook;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.76-81
    • /
    • 2014
  • The purpose of this study was to comparative analysis of tidal volume and airway pressure after one-rescuer BVM, two-rescuer BVM, advanced airway devices with a Bag-valve mask using RespiTrainer. The data were obtained from June 2 to 10 in 2014. The collected data were analyzed using the SPSS WIN 18.0 program. The results showed that BVM ventilation using the endotracheal intubation produced higher mean tidal volume $497{\pm}78mL$, Two-rescuer ventilation $479{\pm}91mL$ One-rescuer ventilation $386{\pm}59mL$, King LTS-D $365{\pm}05mL$, Laryngeal mask airway (LMA) $351{\pm}35mL$. Peak airway pressure was higher in BVM ventilation using the endotracheal intubation. As a result, the study confirmed that the BVM Ventilation by endotracheal intubation and Two-rescuer BVM ventilation to one third the bag depth squeeze method is appropriate.

Effects of small tidal volume and positive end-expiratory pressure on oxygenation in pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation

  • Byun, Sung Hye;Lee, So Young;Jung, Jin Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.165-170
    • /
    • 2018
  • Background: The purpose of this study was to investigate whether tidal volume (TV) of 8 mL/kg without positive end-expiratory pressure (PEEP) and TV of 6 mL/kg with or without PEEP in pressure-controlled ventilation-volume guaranteed (PCV-VG) mode can maintain arterial oxygenation and decrease inspiratory airway pressure effectively during one-lung ventilation (OLV). Methods: The study enrolled 27 patients undergoing thoracic surgery. All patients were ventilated with PCV-VG mode. During OLV, patients were initially ventilated with TV 8 mL/kg (group TV8) without PEEP. Ventilation was subsequently changed to TV 6 mL/kg with PEEP ($5cmH_2O$; group TV6+PEEP) or without (group TV6) in random sequence. Peak inspiratory pressure ($P_{peak}$), mean airway pressure ($P_{mean}$), and arterial blood gas analysis were measured 30 min after changing ventilator settings. Ventilation was then changed once more to add or eliminate PEEP ($5cmH_2O$), while maintaining TV 6 mL/kg. Thirty min after changing ventilator settings, the same parameters were measured once more. Results: The $P_{peak}$ was significantly lower in group TV6 ($19.3{\pm}3.3cmH_2O$) than in group TV8 ($21.8{\pm}3.1cmH_2O$) and group TV6+PEEP ($20.1{\pm}3.4cmH_2O$). $PaO_2$ was significantly higher in group TV8 ($242.5{\pm}111.4mmHg$) than in group TV6 ($202.1{\pm}101.3mmHg$) (p=0.044). There was no significant difference in $PaO_2$ between group TV8 and group TV6+PEEP ($226.8{\pm}121.1mmHg$). However, three patients in group TV6 were dropped from the study because $PaO_2$ was lower than 80 mmHg after ventilation. Conclusion: It is postulated that TV 8 mL/kg without PEEP or TV 6 mL/kg with $5cmH_2O$ PEEP in PCV-VG mode during OLV can safely maintain adequate oxygenation.

Airway obstruction by dissection of the inner layer of a reinforced endotracheal tube in a patient with Ludwig's angina: A case report

  • Shim, Sung-Min;Park, Jae-Ho;Hyun, Dong-Min;Lee, Hwa-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.135-138
    • /
    • 2017
  • Intraoperative airway obstruction is perplexing to anesthesiologists because the patient may fall into danger rapidly. A 74-year-old woman underwent an emergency incision and drainage for a deep neck infection of dental origin. She was orally intubated with a 6. 0 mm internal diameter reinforced endotracheal tube by video laryngoscope using volatile induction and maintenance anesthesia (VIMA) with sevoflurane, fentanyl ($100{\mu}g$), and succinylcholine (75 mg). During surgery, peak inspiratory pressure increased from 22 to $38cmH_2O$ and plateau pressure increased from 20 to $28cmH_2O$. We maintained anesthesia because we were unable to access the airway, which was covered with surgical drapes, and tidal volume was delivered. At the end of surgery, we found a longitudinal fold inside the tube with a fiberoptic bronchoscope. The patient was reintubated with another tube and ventilation immediately improved. We recognized that the tube was obstructed due to dissection of the inner layer.

Harmonic Peak Picking-based MVF Estimation for Improvement of HMM-based Speech Synthesis System Using TBE Model (TBE 모델을 사용하는 HMM 기반 음성합성기 성능 향상을 위한 하모닉 선택에 기반한 MVF 예측 방법)

  • Park, Jihoon;Hahn, Minsoo
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.79-86
    • /
    • 2012
  • In the two-band excitation (TBE) model, maximum voiced frequency (MVF) is the most important feature of the excitation parameter because the synthetic speech quality depends on MVF. Thus, this paper proposes an enhanced MVF estimation scheme based on the peak picking method. In the proposed scheme, the local peak and the peak lobe are picked from the spectrum of a linear predictive residual signal. The normalized distance between neighboring peak lobes is calculated and utilized as a feature to estimate MVF. Experimental results of both objective and subjective tests show that the proposed scheme improves synthetic speech quality compared with that of the conventional one.

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation (압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교)

  • Jeong, Seong-Han;Choi, Won-Jun;Lee, Jung-A;Kim, Jin-A;Lee, Mun-Woo;Shin, Hyoung-Shik;Kim, Mi-Kyeong;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.662-673
    • /
    • 1999
  • Background : Pressure-controlled ventilation (PCV) is frequently used recently as the initial mode of mechanical ventilation in the patients with respiratory failure. Theoretically, because of its high initial inspiratory flow, pressure-controlled ventilation has lower peak inspiratory pressure and improved gas exchange than volume-controlled ventilation (VCV). But the data from previous studies showed controversial results about the gas exchange. Moreover, the comparison study between PCV and VCV with various inspiration : expiration time ratios (I : E ratios) is rare. So this study was performed to compare the respiratory mechanics and gas exchange between PCV and VCV with various I : E raitos. Methods : Nine patients receiving mechanical ventilation for respiratory failure were enrolled. They were ventilated by both PCV and VCV with various I : E ratios (1 : 2, 1 : 1.3 and 1.7 : 1). $FiO_2$, tidal volume, respiratory rate and external positive end-expiratory pressure (PEEP) were kept constant throughout the study. After 20 minutes of each ventilation mode, arterial blood gas, airway pressures, expired $CO_2$ were measured. Results : In both PCV and VCV, as the I : E ratio increased, the mean airway pressure was increased, and $PaCO_2$ and physiologic dead space fraction were decreased. But P(A-a)$O_2$ was not changed. In all three different I : E ratios, peak inspiratory pressure was lower during PCV, and mean airway pressure was higher during PCV. But $PaCO_2$ level, physiologic dead space fraction and P(A-a)$O_2$ were not different between PCV and VCV with three different I : E ratios. Conclusion : There was no difference in gas exchange between PCV and VCV under the same tidal volume, frequency and I : E ratio.

  • PDF

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Bronchial compression in an infant with isolated secundum atrial septal defect associated with severe pulmonary arterial hypertension

  • Park, Sung-Hee;Park, So-Young;Kim, Nam-Kyun;Park, Su-Jin;Park, Han-Ki;Park, Young-Hwan;Choi, Jae-Young
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.8
    • /
    • pp.297-300
    • /
    • 2012
  • Symptomatic pulmonary arterial hypertension (PAH) in patients with isolated atrial septal defect (ASD) is rare during infancy. We report a case of isolated ASD with severe PAH in an infant who developed airway obstruction as cardiomegaly progressed. The patient presented with recurrent severe respiratory insufficiency and failure to thrive before the repair of the ASD. Echocardiography confirmed volume overload on the right side of heart and severe PAH (tricuspid regurgitation [TR] with a peak pressure gradient of 55 to 60 mmHg). The chest radiographs demonstrated severe collapse of both lung fields, and a computed tomography scan showed narrowing of the main bronchus because of an intrinsic cause, as well as a dilated pulmonary artery compressing the main bronchus on the left and the intermediate bronchus on the right. ASD patch closure was performed when the infant was 8 months old. After the repair of the ASD, echocardiography showed improvement of PAH (TR with a peak pressure gradient of 22 to 26 mmHg), and the patient has not developed recurrent respiratory infections while showing successful catch-up growth. In infants with symptomatic isolated ASD, especially in those with respiratory insufficiency associated with severe PAH, extrinsic airway compression should be considered. Correcting any congenital heart diseases in these patients may improve their symptoms.