• Title/Summary/Keyword: Payback Period

Search Result 135, Processing Time 0.026 seconds

Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House (단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가)

  • Byonghu Sohn;Su-In Lee;Jae-Sik Kang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

A Study on the Application Effect of Central-Grid PV System at a Streetlamp using RETScreen - A Case Study of Gwangjin-gu - (RETScreen을 이용한 가로등의 계통연계형 태양광시스템 적용 효과 분석 - 서울시 광진구를 중심으로 -)

  • Kang, Seongmin;Choi, Bong-Seok;Kim, Seungjin;Mun, Hyo-dong;Lee, Jeongwoo;Park, Nyun-Bae;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • With continued economic growth, Korea has seen an increase in the nighttime activities of its citizens as hours of activity have extended into night. There is an increasing trend in energy consumption related to citizens' nighttime activities. In order to analyze ideas for an efficient replacement of the power consumption of streetlights and for profit generation by applying grid-type solar systems, this study used an RETScreen model. Through energy analysis and cost analysis, the application benefit and viability of grid-type solar street light systems were analyzed. With analysis result of a total weekly power generation of 114 kWh via a grid-connected solar streetlight system, it was shown that the net present value of a grid-connected solar street light system is 155,362 KRW, which would mean a payback period of about 5.2 years, and as such, it was shown that profit could be generated after about 6 years. In addition, if the grid-connected solar power generation system proposed by this study is to be applied, it was shown that 401,935 KRW in profit could be generated after the 20-year useful life set for the solar system. In addition, the sensitivity analysis was performed taking into account the price fluctuations of SMP, maintenance. As a result, a payback period has increased by 1~2 years, and there were no significant differences. Because the most important factor that affect the economic analysis is the cost of supply certification of renewable energy, a stable sales and acquisition of this certification are very important. the Seoul-type Feed in Tariff(FIT) connected to other institutions will enable steady sales by confirming to purchase the certification for 12 years. Therefore, if those issues mentioned above are properly reflected, Central-grid PV system project will be able to perform well in the face of unfavorable condition of solar PV installation.

Evaluation of Economic-Environmental Impact of Heat Exchanger Network in Naphtha Cracking Center (납사분해 공정 내 열 교환 네트워크 경제적-환경영향 평가)

  • Hyojin Jung;Subin Jung;Yuchan Ahn
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.378-387
    • /
    • 2023
  • Petrochemical is an energy consuming industry that consumes about 30% of total industrial energy consumption and is a representative carbon dioxide (CO2) emission source. Among them, the Naphtha Cracking Center (NCC), which produces ethylene, propylene, propane and mixed C4, consumes large amounts of energy and emits significant amounts of CO2. For this reason, an integrated techno economic- environmental impact assessment aimed at reducing energy consumption and environmental impact factors is necessary to ensure efficiency in terms of economics and environment. This study aims to analyze the efficiency of the heat exchanger network used in the existing NCC base on the pinch analysis and select an improvement plan that can reduced energy consumption. In order to reduces the utility consumption in the process, an optimal heat exchanger network considering the high-temperature and low-temperature stream was derived, and the economic evaluation was conducted by considering the trade-off between the reduction in utility consumption and the increase in heat exchanger installation cost. In addition, an environmental impact assessment was conducted on the reduced CO2 emission in consideration of the environmental aspect, and the economic environmental impact assessment used the payback period to recover the invested funds to come up with an energy saving plan that can be applied based on the actual process. As a result of considering the economic-environmental impact assessment, when the environmental impact assessment was not considered, it was 4.29 months, 3.21 months, and 3.39 months for each case, and when considering the environmental impact assessment, it was 4.24 months, 3.17 months, and 3.35 months for each case. These results appeared equally both when the environmental impact assessment was not include and when it was include. In addition, a sensitivity analysis was conducted for each case to determine how important factors affect the payback period. As a result of the sensitivity analysis, the cost of the heat exchanger was identified as a major factor influencing the overall cost.

To Improve Production Process of the Modular Using the Conveyor System (모듈러 공장생산 프로세스 개선을 위한 컨베이어시스템 적용 방안 - 공장생산 중심으로 -)

  • Bae, Byung-Yoon;Kim, Kyung-Rai;Cha, Hee-Sung;Shin, Dong-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.5
    • /
    • pp.103-112
    • /
    • 2012
  • Republic of Korea is recently becoming an advanced country with increasing standard of living. This is causing a lack of employment in the construction industry because of high labor costs and it is resulting rapid increase in foreign labors. Modular Method of Construction can be defined as 50%~90% of the entire process is completed in factory, and transferred to construction field to install. The main purpose of this process is to minimize the entire process that possibly can be done at construction field in order to maximize the quality. The current local usage of Modular Method of Construction started at Shin Ki Elementary School during 2003 and it is widely used for military facilities. It should be used more because it has strengths of spending short time period to complete and low production costs. It can make a change if Modular Method of Construction is applied. Toyota is currently producing vehicle with conveyor system and if Modular Method of Construction is applied, then it is possible to reduce the waste of labor, and automatic production time. Expansion of the modular Market can be expected by applying this method because it will improve producing costs, high quality, and enforced process. This research tried to solve the problem of factory's manufacturing production by applying local Modular Method of Construction to provide suggestions and analyze the profitability with applied conveyor system. It is depending on produced model, but this research's model will take 20 months including assessment of payback period.

Economic Evaluations of CO2 Capture Process from Power Plant Flue Gas Using Dry Sorbents (건식 흡수제를 이용한 발전소배가스의 CO2 회수공정 경제성분석)

  • Shin, Byung Chul;Kwak, Hyun;Lee, Kwang Min
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.646-653
    • /
    • 2012
  • We studied the economic evaluations on Korea Institute of Energy Research (KIER)'s $CO_2$ capture process using dry sorbents, and compared the results with those of comparable technologies. Capital and operating costs of the $CO_2$ capture system for 500 MW coal fired power plant were estimated to determine the economic feasibility. LCOE (Levelized Cost of Energy) and $CO_2$ capture cost appeared 32.46$/MWh and 28.15$/ton$CO_2$, respectively. The internal rate of return (IRR), the net present values (NPV), and the payback period (PBP), were calculated by assuming several variables. As the result of calculation, IRR of KIER's $CO_2$ capture system was 15%, NPV was calculated 6,631,000$, and PBP was 5.93 years at $50/t$CO_2$ of CER price. Consequently, this process can compete with other comparative processes using dry sorbents.

"Servicescape" Differentiation in a Hair Salon (헤어살롱 서비스스케이프 차별화 성공사례)

  • Lee, Sang-Hyun;Park, Chul-Ju
    • Journal of Distribution Science
    • /
    • v.13 no.9
    • /
    • pp.71-79
    • /
    • 2015
  • Purpose - The purpose of this paper is to find out the effect of changes in the differentiated "servicescape" on the business performance in the hair salon industry using a case study. For this, we selected hair salon M located in Suwon. The shop is innovatively different from existing shops in terms of spatial layout and functionality. We conducted in-depth research, beginning with the launch of the shop concept through investment and ongoing stable sales. Research design, data, and methodology - The M hair salon is a start up shop providing a differentiated servicescape (physical environment where the service takes place) located in Suwon, Yeongtong-gu. We conducted research to investigate how spatial layout and functionality of the servicescape impact customers' perceived quality. The interview period and case analysis was May 2014 through March 2015, covering 11 months. To conduct the case analysis, we analyzed the spatial layout and functionality of existing shops and interviewed customers and experts about the difference between hair salon M and existing shops. Results - Our results found clues to the positive effect of spatial layout and functionality among servicescape factors on perceived service quality at the salon. The shop showed a fast payback of the principal investment, growth potential in contrast to competitors near the salon, and 45 percent returning customers. The problem with the spatial layout at existing shops was that customers were aware of the way other people were looking at them, since viewing angles overlapped, therefore there was a limitation to the relationship intensity with an exclusive hair designer. In contrast, the layout of the stands at the M salon kept the number of dressing stands limited to maximize the customer's emotional response. Additionally, because of the new layout of dressing stands hiding other customer voices and appearance in the salon, customers perceived their service space as independent. Therefore, they did not have to focus on their personal emotional response, which was one of the advantages of the new layout. Conclusions - This study conducted case study analysis by offering a new perspective focusing on spatial layout, previously not considered as an independent variable of quality evaluations and customer satisfaction in existing literature on hair salon management. Therefore, this study contributes to the field by offering an opportunity to discover the causal relationships between the overlooked physical environment and a customer's perceived quality. However, a process objectifying the results of the study through empirical analysis and hypotheses is needed to overcome the limitations of the case study approach and generalize the results. Moreover, it would be beneficial to conduct further empirical study of the relationship between the spatial layout provided in the case and a customer's emotional response and change in mood. In addition, an analysis is needed regarding how customers feel about the factors using the Kano Model. These suggestions would be considered in further study.

Process Simulation and Economic Feasibility of Upgraded Biooil Production Plant from Sawdust (톱밥으로부터 생산되는 개질 바이오오일 생산공장의 공정모사 및 경제성 분석)

  • Oh, Chang-Ho;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.496-523
    • /
    • 2018
  • The objective of this study is to evaluate the economic feasibility of two fast pyrolysis and biooil upgrading (FPBU) plants including feed drying, fast pyrolysis by fluidized-bed, biooil recovery, hydro-processing for biooil upgrading, electricity generation, and wastewater treatment. The two FPBU plants are Case 1 of an FPBU plant with steam methane reforming (SMR) for $H_2$ generation (FPBU-HG, 20% yield), and Case 2 of an FPBU with external $H_2$ supply (FPBUEH, 25% yield). The process flow diagrams (PFDs) for the two plants were constructed, and the mass and energy balances were calculated, using a commercial process simulator (ASPEN Plus). A four-level economic potential approach (4-level EP) was used for techno-economic analysis (TEA) under the assumption of sawdust 100 t//d containing 40% water, 30% equity, capital expenditure equal to the equity, $H_2$ price of $1050/ton, and hydrocarbon yield from dried sawdust equal to 20 and 25 % for Case 1 and 2, respectively. TCI (total capital investment), TPC (total production cost), ASR (annual sales revenue), and MFSP (minimum fuel selling price) of Case 1 were $22.2 million, $3.98 million/yr, $4.64 million/yr, and $1.56/l, respectively. Those of Case 2 were $16.1 million, $5.20 million/yr, $5.55 million/yr, and $1.18/l, respectively. Both ROI (return on investment) and PBP (payback period) of Case 1(FPBU-HG) and Case 2(FPBU-EH) were the almost same. If the plant capacity increases into 1,500 t/d for Case 1 and Case 2, ROI would be improved into 15%/yr.

Economic Assessment of the Battery Energy Storage System with Its Customer Type (수용가 형태에 따른 전지전력저장시스템의 경제성 평가)

  • 손학식;최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.81-89
    • /
    • 2002
  • The Battery Energy Storage System (BESS) has lots of advantages such as load leveling, quick response emergency power (spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. However, it is very critical that economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS in nation widely. In this paper, we proposed the economic assessment model of customer owned BESS which is complemented and improved the existing model. The proposed model is applied to the typical customer types, i.e. light industrial, commercial, and residential, which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic viability performed for each customer load type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, Net Present Worth (NPW), Rate Of Return (ROR). The results show that the BESS has economic benefits to the specific customer type, i.e. residential customer. Therefore, the government and the energy agency should be committing the support program, such as tax incentive, financial support, to disseminate the BESS nation widely. The results of this paper are useful to the customer investment decision-making and the national energy policy & strategy in Korea.

Economic Evaluations of DCL/ICL Processes (직·간접석탄액화공정의 경제성 평가)

  • Park, Joo-Won;Bae, Jong-Soo;Kweon, Yeong-jin;Kim, Hak-Joo;Jung, Heon;Han, Choon
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.781-787
    • /
    • 2009
  • This report investigates the economic proprieties of commercial 50,000 barrel per day direct/indirect coal liquefaction(DCL/ICL) plants to produce commercial-grade diesel and naphtha liquids. The scope of the study includes capital and operating cost estimates, sensitivity analyses and a comparative financial analyses. Based on plant capacity of 50,000BPD, employing Illinois #6 bituminous coal as feed coal, the total capital cost appeared $3,994,858,000(DCL) and $4,962,263,000(ICL). Also, the internal rate of return of DCL/ICL appeared 13.27% and 12.68% on the base condition respectively. In this case, coal price and sale price of products were the most influence factors. And ICL's payback period(6.8 years) was longer than DCL's(6.6 years). According to sensitivity analyses, the important factors on both DCL/ICL processes were product sale price, feed coal price and the capital cost in order.

Reuse Technology Development and Economic Evaluation of Dyeing Wastewater Treatment Sludge (폐수처리슬러지의 재활용기술개발 및 경제성 평가 -B염색조합을 중심으로-)

  • 임재호;이정연
    • Resources Recycling
    • /
    • v.9 no.1
    • /
    • pp.36-43
    • /
    • 2000
  • This study was carried out for treatment and reuse of inorganic sludge from Fenton process at B dyeing wastewater treatment plant. The parameters for pilot-scale treatment system were derived from the results of this study. It was found that $COD_{cl}$ of the treated effluent became lower than 100 mg/l approximately on the optimal reaction condition. 2nd sludge which was generated after redissolving sludge was analyzed, and it showed that reduction ratio of ash in 2nd sludge and total dry sludge weight in comparison with current sludge were 85% and 65%. Also Fe salt in sludge was redissolved about 90~95% of initial Fe by weight. It was estimated almost ₩350,000,000 for sludge reuse process. It was estimated saving of about ₩1,300,000 per day (₩420,000,000 per year) in operating cost based on 30,000 $m^3$/d treatment, which these were about ₩430,000 per day in chemical, ₩1,100,000 per day in sludge transportation and ₩200,000 per day in equipment maintenance. Payback period with interest charge for investment cost was estimated about 10.5 months. Also, net present value (NPV) was ₩792,000,000 and internal rat of return (IRR) was about 110%.

  • PDF