• Title/Summary/Keyword: Patient evaluation

Search Result 3,043, Processing Time 0.031 seconds

Efficacy of I-123/I-131 Metaiodobenzylguanidine Scan as A Single Initial Diagnostic Modality in Pheochromocytoma: Comparison with Biochemical Test and Anatomic Imaging (갈색세포종의 초기 진단에서 I-123/I-131 Metaiodobenzylguanidine 스캔의 단일 검사로써의 진단 성능: 생화학적 검사, 해부학적 영상과 비교)

  • Moon, Eun-Ha;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.436-442
    • /
    • 2009
  • Purpose: We underwent this study to evaluate the diagnostic potential of I-123/I-131 metaiodobenzylguanidine (MIBG) scintigraphy alone in the initial diagnosis of pheochromocytoma, compared with biochemical test and anatomic imaging. Materials & Methods: Twenty two patients (M:F=13:9, Age: $44.3{\pm}\;19.3$ years) having the clinical evaluation due to suspicious pheochromocytoma received the biochemical test, anatomic imaging modality (CT and/or MRI) and I-123/I-131 MIBG scan for diagnosis of pheochromocytoma, prior to histopathological confirmation. MIBG scans were independently reviewed by 2 nuclear medicine physicians. Results: All patients were confirmed histopathologically by operation or biopsy (incisional or excisonal). In comparison of final diagnosis and findings of each diagnostic modality, the sensitivities of the biochemical test, anatomic imaging, and MIBG scan were 88.9%, 55.6%, and 88.9%, respectively. And the specificities of the biochemical test, anatomic imaging, and MIBG scan also were 69.2%, 69.2%, and 92.3%, respectively. MIBG scan showed one false positive (neuroblastoma) and one false negative finding. There was one patient with positive MIBG scan and negative findings of the biochemical test, anatomic imaging. Conclusion: Our data suggest that I-123/I-131 MIBG scan has higher sensitivity, specificity, positive predictive value, negative predictive value and accuracy than those of biochemical test and anatomic imaging. Thus, we expect that MIBG scan is e tectively used for initial diagnosis of pheochromocytoma alone as well as biochemical test and anatomic imaging.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Clinical Result of Layered Suture Bridge Technique in Arthroscopic Repair for Delaminated Rotator Cuff Tear (회전근 개 층간 분리 파열에서 관절경을 이용한 층상 교량형 봉합술의 임상 결과)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Kim, Dong-Whan;Keum, Sang-Wook;Cha, Jung-Kwon
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.84-93
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repair integrity and clinical outcomes of delaminated tears following arthroscopic layered suture bridge rotator cuff repair in a prospective fashion. Materials and Methods: A consecutive series of 67 patients with delaminated rotator cuff tears who underwent surgery using the arthroscopic Layered Suture Bridge Technique were followed prospectively. Of 67 shoulders, 26 patients were male and 40 patients were female (one patient had bilateral tears); the mean age was 58.8(40~76) years. The clinical evaluation was performed according to ASES, UCLA, and KSS (Korea Shoulder Scoring System) scores with an average follow up period of 33 months. Repair integrity was estimated using MRI, which was performed six months postoperatively. Results: The average clinical outcome in ASES, UCLA, and KSS scores showed significant improvement at the time of the final follow-up compared to preoperatively, from 50.2 to 92.3, 15 to 31.3, and 54.4 to 90.7, respectively (p<0.001 for all scores). Follow up by MRI showed that 16 shoulders had a type-I; 14, a type-II; five, a type-III; two, a type-IV; one, a type-V re-tear. The overall rate of re-tear (types IV and V) was 7.9%. Conclusion: Use of the Arthroscopic Layered Suture Bridge Technique can result in improved functional and structural outcome in cases of delaminated rotator cuff tear.

Novel Real Time PCR Method for Detection of Plasmodium vivax (새로운 Real Time PCR 방법을 통한 Malaria(Plasmodium vivax)의 검출)

  • Ki, Yeon-Ah;Kim, So-Youn
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Malaria is a re-emerging infectious disease that is spreading to areas where it had been eradicated, such as Eastern Europe and Central Asia. To avoid the mortality from malaria, early detection of the parasite is a very important issue. The peripheral blood smear has been the gold standard method for the diagnosis of malaria infection. Recently, several other methods have been introduced for quantitative detection of malaria parasites. Real time PCR that employs fluorescent labels to enable the continuous monitoring of PCR product formation throughout the reaction has recently been used to detect several human malaria parasites. 18S rRNA sequences from malaria parasites have been amplified using Taqman real time PCR assay. Here, a SYBR Green-based real time quantitative PCR assay for the detection of malaria parasite-especially, Plasmodium vivax - was applied for the evaluation of 26 blood samples from Korean malaria patients. Even though SYBR Green-based real time PCR is easier and cheaper than Taqman-based assay, SYBR Green-based assay cannot be used because 18S rRNA cannot be specifically amplified using 1 primer set. Therefore, we used DBP gene sequences from Plasmodium vivax, which is specific for the SYBR Green based assays. We amplified the DBP gene from the 26 blood samples of malaria patients using SYBR Green based assay and obtained the copy numbers of DBP genes for each sample. Also, we selected optimal reference gene between ACTB and B2M using real time assay to get the stable genes regardless of Malaria titer. Using selected ACTB reference genes, we successfully converted the copy numbers from samples into titer, ${\sharp}$ of parasites per microliter. Using the resultant titer from DBP based SYBER Green assay with ACTB reference gene, we compared the results from our study with the titer from Taqman-based assay. We found that our results showed identical tendency with the results of 18S rRNA Taqman assay, especially in lower titer range. Thus, our DBP gene-utilized real time assay can detect Plasmodium vivax in Korean patient group semi-quantitatively and easily.

Organic Acidopathies as Etiologic Diseases of Developmental Delay in Korean Childhood and Adolescent Age Group (한국인 소아청소년기 발달지연의 원인질환으로서의 유기산대사이상질환)

  • Lee, Jong Yoon;Lee, Ye Seung;Choi, Joong Wan;Bae, Eun Joo;Park, Won Il;Oh, Phil Soo;Lee, Hong Jin
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.12 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: Developmental delay is caused by very diverse etiologic diseases. Most chronic disorders has some influence on development. Chronic or acute disorders of CNS are main etiologic diseases of developmental delay. Up to now, over 60 diseases are included in organic acidopathies and most of them causes acute or chronic recurrent CNS damage and developmental delay. We have done this study to find out the importance of organic acidopathies causing developmental delay in Korean childhood and adolescent patients. Method: Retrograde analysis for 738 patients with developmental delay whose clinical informations are available and have done urine organic acid analysis for 5 years period, between Jan. 1st 2007 to Dec. 31th 2011. Statistical analysis was done with Student's t test using SPSS. Result: Out of 738 patients, 340 patients (46.1%) showed abnormalities on urine organic acid analysis. The most frequent disease was mitochondrial respiratory chain disorders (MRCD) (253, 34.3%), followed by ketolytic defects(39, 5.3%), 3-hydroxyisobutyric aciduria (26, 3.5%), glutaric aciduria type II (8, 1.1%), pyruvate dehydrogenase deficiency (3, 0.4%), 3-methylglutaric aciduria (2, 0.3%), glutaric aciduria type I (2, 0.3%), ethylmalonic aciduria (1, 0.15%), methylmalonic aciduria (1, 0.15%), HMG-CoA lyase deficiency (1, 0.15%), 3-methylcrotonylglycinuria (1, 0.15%), fatty acid oxidation disorders(1, 0.15%) and FAOD (1, 0.15%). Conclusion: Mitochondrial disorders are most frequent etiologic disease on all age group, followed by ketolytic defects and various organic acidopathies. The number and diversities of organic acidopathies emphasize meticulous evaluation of basic routine laboratory examinations and organic acid analysis with initial sample on every developmental patient.

  • PDF

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter (열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가)

  • Kim, Sang-Tae;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.336-343
    • /
    • 2010
  • Coronary artery CT angiography has short scanning length, the exposure dose is high. Therefore, it is required to study on the organ dose when using MDCT. We compared the differences between the absorbed dose and effective dose in the major organs assessing the absorbed dose in the major organs by 16-MDCT and 64-MDCT in the subjects with coronary artery CT angiography, the same protocol by 16-MDCT and 64-MDCT. As a result, the great orders of absorbed dose when conducting coronary artery CT angiography had been shown as heart, stomach, liver, pancreas, kidney, spleen, large intestine, lung, small intestine, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$ in 16-MDCT, and heart, stomach, pancreas, spleen, liver, kidney, small intestine, large intestine, lung, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$ in 64-MDCT, demonstrating some different distributions. The exposed doses to the patient per one time scanning with coronary artery CT angiography were $71.316{\pm}4.316mGy$ in 16-MDCT as the absorbed dose based on the heart and $115.26{\pm}1.59mGy$ in 64-MDCT. The effective doses were 7.41 mSv and 12.11 mSv in 16 and 64-MDCT, respectively. Taking into account the results of brain CT with 2.8 mSv that has comparatively large scanning length and size, facial CT 0.8 mSv, chest CT 5.7 mSv, pelvic CT 7.2 mSv, and abdominal and pelvic CT 14.4 mSv, it is very high considering the scanning length of 13 cm limited to the heart for the scanning range.

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

Lung Volumes and Diffusing Capacity in Bronchiectasis: Correlation with the Findings of High Resolutional CT (기관지확장증의 흉부고해상전산화단층촬영소견과 폐기량 및 폐확산능과의 관계)

  • Kim, Yeon-Jae;Park, Jae-Yong;Won, Jun-Hee;Kim, Chang-Ho;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.489-499
    • /
    • 1999
  • Background: The patient with bronchiectasis may have obstructive ventilatory impairment combined with mild restrictive ventilatory impairment due to fibrosis of surrounding lung parenchyme and pleural adhesions caused by chronic recurrent pulmonary infections. Since hyperinflation or emphysematous change can be occured in bronchiectasis, pulmonary functions such as lung volumes and diffusing capacity may also vary with associated emphysema. Methods: For the evaluation of lung volumes and diffusing capacity in bronchiectasis with respect to the anatomic types and severity of bronchiectasis, a total of 40 cases comprising 24 cases of tubular, and 16 cystic type of bronchiectasis were analyzed retrospectively. Correlation between lung functions and extent of bronchiectasis or associated emphysema detected in HRCT were also evaluated. Results: Vital capacity(VC) tended to decrease in cystic type than in tubular type. As the severity of bronchiectasis became serious, the VC were significantly reduced, whereas the total lung capacity(TLC), residual volume(RV) and its ratio to the total lung capacity(RV/TLC) had no significant difference. Lung clearance index(LCI) was significantly increased in cystic type than in tubular type, whereas the slope of phase III in single breath nitrogen curve($\triangle$N2/L) was not significantly changed regard to the type and severity of bronchiectasis. DLCO and DLCO/VA reflecting diffusing capacity were significantly decreased in cystic type and also as the severity of bronchiectasis became serious. The correlation coefficient of VC, DLCO and LCI with the extent of bronchiectasis were -0.322, -0.339 and 0.487, respectively, whereas other parameters were not significantly correlated with the extent of bronchiectasis. VC and DLCO correlated negatively with the extent of emphysema while RV, RV/TLC, LCI and $\triangle$N2/L correlated positively. Conclusion: These findings suggest that the reduction of VC and diffusing capacity or uneven distribution of inspired gas in bronchiectasis are related to both the extent of bronchiectasis and associated emphysema while increased residual volume be related to the extent of associated emphysema alone.

  • PDF

Evaluation of Tumor Registry Validity in Samsung Medical Center Radiation Oncology Department (삼성서울병원 방사선종양학과 종양등록 정보의 타당도 평가)

  • Park Won;Huh Seung Jae;Kim Dae Yong;Shin Seong Soo;Ahn Yong Chan;Lim Do Hoon;Kim Seonwoo
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • Purpose : A tumor registry system for the patients treated by radiotherapy at Samsung Medical Center since the opening of a hospital at 1994 was employed. In this study, the tumor registry system was introduced and the validity of the tumor registration was analyzed. Materials and Methods: The tumor registry system was composed of three parts: patient demographic, diagnostic, and treatment Information. All data were input in a screen using a mouse only. Among the 10,000 registered cases in the tumor registry system until Aug, 2002, 199 were randomly selected and their registration data were compared with the patients' medical records. Results : Total input errors were detected on 15 cases (7.5%). There were 8 error items In the part relating to diagnostic Information: tumor site 3, pathology 2, AJCC staging 2 and performance status 1. In the part relating to treatment information there were 9 mistaken items: combination treatment 4, the date of initial treatment 3 and radiation completeness 2. According to the assignment doctor, the error ratio was consequently variable. The doctors who 010 no double-checks showed higher errors than those that 010 (15.6%:3.7%). Conclusion: Our tumor registry had errors within 2% for each Item. Although the overall data qualify was high, further improvement might be achieved through promoting sincerity, continuing training, periodic validity tests and keeping double-checks. Also, some items associated with the hospital Information system will be input automatically In the next step.