• 제목/요약/키워드: Patient Uniform

검색결과 91건 처리시간 0.028초

X선관의 실효초점 측정에 관한 고찰 (Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes)

  • 장광현;임오수;김형기;송창욱;정경모;정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권1호
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

점액 유두상 상의세포종의 압착도말 세포학적 소견 - 1예 보고 - (Crush Cytologic Findings of Myxopapillary Ependymoma in Spinal Cord - A Case Report -)

  • 정수진;양영일
    • 대한세포병리학회지
    • /
    • 제10권1호
    • /
    • pp.73-78
    • /
    • 1999
  • Myxopapillary ependymoma generally arise in the conus medullaris and filum terminale of adult spinal cord. These tumors are readily recognized due to unique histopathologic features, however, their cytologic features are not well described. When only a tiny sample is obtained, cytologic examination using crush preparation may be a useful diagnostic tool to help appropriate intraoperative diagnosis. We present the crush cytologic features of myxopapillary ependymoma arising in thoracic and lumbar spinal cord of a 13-year-old boy. The patient had complained of paraparesis and back pain for 1 month. The MRI image revealed a relatively well demarcated intramedullary mass in T11-L1 levels. Crush preparation for cytology were peformed by biopsy material. Crush cytologic findings revealed high cellularity and small sized branching papillary clusters on fibrillary or mucinous background. The tumor cells had uniform round or elongated nuclei. The cytoplasmic process of tumor cells were attached to the vascular wall. Between the tumor cells and vascular walls, the perivascular collar of globoid acellular stroma with metachromatic reaction on toluidin blue stain was noted. The crush preparation of myxopapillary ependymoma is considered as a simple and highly accurate diagnostic tool for differentiation from other intramedullary neoplasms of central nervous system.

  • PDF

이중음성을 보인 변성발성장애 환자 음성의 음향학적 특성 및 치험례 -증 례 보 고- (Diplophonia in Mutational Falsetto : Acoustic Characteristics and Treatment -A Case Report-)

  • 임재열;임성은;이성은;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제15권1호
    • /
    • pp.47-51
    • /
    • 2004
  • Normally, as a result of increased laryngeal growth, the male voice drops about one octave in pitch level during adolescence. Failure of the voice to drop in pitch is consider to be a clinically significant voice disorder - 'mutational dysphonia'. The aim of this article is to evaluate the changes brought about by voice therapy, using the analysis of the EGG measure from Lx Speech Studio program(Laryngograph Ltd, UK) as well as acoustic, and aerodynamic studies in 18-year-old mutational dysphonia patient. The results from the Lx Speech Studio program demonstrated bimodal distribution of DFx(Hz), DQx(%), QxFx and diplophonic characteristic. After voice therapy combined with manual compression method, the distribution of DFx, DQx, QxFx was changed uniform with a dramatic reduction of higher pitch level. In addition, this finding suggests the EGG measure helps to choice treatment options, monitor the efficacy of therapy, and estimate the prognosis of diseases.

  • PDF

CT 조영제 혈관외유출의 방사선학적 고찰 (Radiological Evaluation of CT Contrast Medium Extravasation)

  • 권대철;박창희;정재호;강희두;송은홍
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.39-49
    • /
    • 2008
  • Extravasation of contrast material is a not infrequent complication of enhanced imaging studies and large volume extravasation may result in severe damage. Subcutaneous extravasation of the radiographic contrast medium is one of the complications of the contrast medium-enhanced procedures. Automated power injectors enable the contrast material to be delivered at a uniform high-flow-rate and as a nonfragmented bolus, and this is essential for many contrast material enhanced CT(computed tomography) applications. The major risk associated with the use of automated power injectors is the well known complication of contrast material extravasation at the injection site. Automated injection of CT contrast material can produce the compartment syndrome. Selection of the nonionic contrast material after careful evaluation of the intravenous administration site and monitoring of the patient during the use of a mechanical power injector may help minimize or prevent extravasation injuries. Early identification is important and conservative management is effective in most cases. Prevention of these injuries with the education of radiological technologist remains the ultimate aim.

  • PDF

보호자없는 병원과 간호인력 활용방안 (Increasing the use of nursing staff in hospitals instead of relying on family members' assistance)

  • 유선주
    • Perspectives in Nursing Science
    • /
    • 제6권1호
    • /
    • pp.77-83
    • /
    • 2009
  • The number of nurses per bed at acute-stage hospitals is quite low in Korea compared with other OECD countries. In order to prevent the degradation of the quality of inpatient nursing services due to insufficient nurse staffs, the national health insurance introduced the differentiated nursing care fee system. This did not work as a motive for inducing the employment of nursing staff due to insufficient cost compensation. Because of insufficient nursing staff, family members have to stay with the patient or patients have to hire a personal care attendant. This increases the burden and cost to families. For the activation of hospitals without guardians, there should be policies for raising additional nursing staff such as standardizing jobs among nursing staff, particularly between nurses and nursing assistants, setting adequate standards of staffing in nursing according to medical service, substantiating the cost of nursing under the differentiated nursing care fee system, improving the medical fee system of hospitals without guardians including health insurance payment, supplying nursing staff stably through improving their working conditions such as providing child rearing services and salary increase, clarifying the qualification of personal care attendants working at acute.stage hospitals, developing indexes for assessing the quality of nursing care services, and monitoring for the management of uniform quality.

  • PDF

뇌압 펄스에 의한 션트밸브의 압력-유량제어 특성의 변화 (Changes in The Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation)

  • 홍이송;이종선;장종윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.391-395
    • /
    • 2002
  • 수두증 환자를 치료하기 위해 머리에 시술 되는 션트밸브가 받는 뇌압 펄스가 밸브의 유량조절 특성에 미치는 영향을 수치적으로 해석하였다. 션트밸브를 통한 유량을 계산하기 위하여 밸브 다이아프램이 형성하는 유량 오리피스를 모델링 하여 맥동압력과 변동하는 압력에 의한 다이아프램의 움직임을 고려하였다. 연구 결과, 압력 펄스와 이에 따른 다이아프램의 움직임에 의하여 유량이 40% 이상 증가함을 보였다. 이 결과는, 뇌실에 시술 되는 션트밸브의 압력-유량 조절특성이 제조 직후 맥동이 없는 유량을 공급하는 시린지 펌프를 사용하여 구한 실험 결과와 상당히 다르다는 사실을 보여주었다.

전신조사방사선치료에서 열형광선량계를 이용한 선량 측정과 체질량지수에 관한 고찰 (Study on Dosimetry Used TLD Dosimeter and Body Mass Index at Total Body Irradiation)

  • 서동린;김연수;김대섭;윤화룡;백금문;곽정원
    • 대한방사선치료학회지
    • /
    • 제23권2호
    • /
    • pp.91-96
    • /
    • 2011
  • 목 적: 전신조사방사선치료를 시행한 환자에서 체질량지수와 열형광선량계를 이용한 선량측정 정보를 비교 분석하여 환자에게 보다 균등한 선량을 조사하고자 한다. 대상 및 방법: 2006년부터 2011년 8월까지 전신조사방사선치료를 시행한 환자 28명을 대상으로 하였다. 각 환자는 열형광선량계를 이용하여 두부, 경부, 흉부, 복부, 골반부, 대퇴부, 슬관절부, 족관절부에서 선량을 측정하였다. 각각의 환자에 대하여 처방 중심점인 복부점과 각 측정점에서의 선량측정치를 비교하였고, 선량기준이 되는 복부점의 측정값과 환자의 체질량지수를 비교 분석하였다. 결 과: 28명 환자에서 처방에 기준이 되는 중심점인 복부선량은 평균 $100.6{\pm}5.5%$이었고, 복부점과 다른 7개의 측정점 평균값과의 최대 차이는 두부, 경부, 흉부, 골반부, 대퇴부, 슬관절부, 족관절부에서 각각 $92.8{\pm}4.2%$, $97.6{\pm}6.2%$, $96.4{\pm}5.5%$, $102.6{\pm}5.3%$, $103.4{\pm}7.9%$, $95.8{\pm}5.9%$, $96.1{\pm}5.5%$였다. 각각의 환자에 대하여 복부점의 선량과 환자의 체질량지수와 관계를 산점도(scatter plot)로 나타내고 선형관계를 회귀분석 한 결과, 회귀직선은 선량(y)=-1.009 BMI (x)+123.3이고 $R^2$값은 0.697로 나타났다. 결 론: 전신방사선치료시 열형광선량계로 측정된 자료를 바탕으로 선량을 평가하였고 분석 결과 처방 선량에 대하여 기준이 되는 복부선량은 평균 $100.6%{\pm}5.5%$로 만족하였다. 본 실험결과 체질량지수와 선량과의 관계 분석을 통하여 얻은 정보에 따라 체질량지수가 높은 환자에 대하여 보정 값을 적용한다면 보다 균등한 선량을 달성할 수 있을 것으로 사료된다.

  • PDF

A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF

치과환자의 치과위생사 복장에 대한 선호도 연구 (A Study on the Dental Patient's Preference of Dental Hygienists' Attire)

  • 유미선;이지연
    • 치위생과학회지
    • /
    • 제4권2호
    • /
    • pp.49-53
    • /
    • 2004
  • 환자들의 치과 치료시 심리적으로 안정이 되고 편안하게 보일 수 있는 복장을 제시하고 치과위생사의 이미지 향상을 위해 치과에 내원한 성인환자 486명을 대상으로 2003년 1월 20일부터 2월 20일까지 자기기입식에 의한 설문조사를 실시하였으며 그 결과는 다음과 같다. 1. 선호하는 의복형태에 대해 39.1%의 환자들이 투피스치마를 가장 선호하였고 일반적 특성에 따른 의복형태 분석결과 성별에서 유의한 차이가 나타났다(p<0.01). 2. 의복색상에 대해 36.2%의 환자들이 분홍색 계열을 선호하였다. 3. 선호하는 신발은 44.2%의 환자들이 샌들을 가장 선호하였고 일반적 특성에 따른 분석결과 연령(p<0.01), 성별(p<0.05)에서 유의한 차이가 나타났다. 4. 머리스타일은 환자들의 43.6%가 뒤로 묶은 머리를 가장 선호하였고 일반적 특성에 따른 분석결과 연령(p<0.05), 성별(p<0.01)에서 유의한 차이가 나타났다. 5. 선호하는 화장정도는 45.9%의 환자들이 전체화장을 가장 선호했으며 일반적 특성에 따른 분석결과 성별(p<0.01)에서 유의한 차이가 나타났다. 6. 치과위생사 표시방법으로 환자들의 60.7%가 명찰을 가장 선호하였고 일반적 특성에 따른 분석결과 연령(p<0.05)에서 유의한 차이가 나타났다. 7. 자신이 선호하는 복장에 대해 75.9%의 환자들이 자신에게 안정을 준다고 하였다.

  • PDF

분말사출성형을 이용한 다수 캐비티 치과용 요오드 용기 금형제작에 관한 연구 (A Study on mold manufacture of multi-cavity dental iodine container using powder injection molding)

  • 최재훈
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 2014
  • 치과에서 사용되는 구강 치료용 요오드 용기는 개폐 시 용기의 캡에 부착되어 있는 칼날에 의해 치료용 실은 절단이 된다. 금속의 칼날은 요오드 용액과 반응하여 단기간에 부식이 되는 문제로 인해 환자의 위생에도 영향을 준다. 이러한 문제를 해결하기 위해 최근 세라믹 칼날로 대체되어진 제품들도 개발되어 생산되는데, 이때 세라믹 칼날은 수작업과 기계가공을 통해 만들어 진다. 본 연구에서는 세라믹 칼날을 분말사출성형공정으로 대량 생산할 수 있도록 20Cavity의 균일 충전을 위한 유동 시스템을 제안하였다. Moldflow를 이용하여 20cavity 유동성에 대한 시뮬레이션을 진행하였고, 금형제작과 수정을 통해 금형을 완성하였다. 사출성형 후 탈지와 소결공정을 통해 완성하고, 금형에 세라믹 칼날을 인서트 사출하여 캡 제품을 완성하였다. 본 연구를 통해 유효한 절단 성능을 갖는 세라믹칼날 대량생산 가능성을 검증하였다.