• Title/Summary/Keyword: Patient Monitoring System

Search Result 344, Processing Time 0.026 seconds

The Development of Patient Monitoring System Using Microcomputer (마이크로컴퓨터를 이용한 환자감시장치의 개발)

  • Kim, N.H.;Park, Y.C.;You, S.K.;Kim, W.K;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1280-1283
    • /
    • 1987
  • In this paper, we represent the development of microcomputer-based monitoring system which monitors patient's states-ECG, blood pressure, temperature and respiration. And since data acquisition and system controls are processed by microprocessor, this system improved the conventional method.

  • PDF

A Design of Intelligent Patient Monitoring System using Model Base (모델 베이스를 이용한 지능적 환자 감시 시스템의 설계)

  • Kim, Jung-Ook;Lee, Seok-Pil;Chi, Sung-Do;Park, Sang-Hui
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.155-159
    • /
    • 1995
  • A design method that can easily construct intelligent patient monitoring systems is proposed. To achieve the design method, the SES/MB concept and a discrete event-based logic control formalism based on a set theory is introduced. In this control paradigm the controller expects to receive confirming sensor responses to its control commands within definite time windows determined by DEVS model of the system under control. Because data to be used for rule-based symbolic reasoning are to be abstracted, several AI methods are applied the processes. These methods are applied to intelligent patient monitoring systems so that they facilitate transformation from low level raw data to high level linguistic data. Model-based system representations have advantages of reusability, extensibility, flexsibility, independent testability and encapsulation.

  • PDF

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

A Wireless ECG monitoring System for Application in Life Emergency Event Detection and Analysis (긴급환자 상황인식 및 분석을 위한 무선 ECG모니터링 시스템)

  • Bhardwaj Sachin;Lee Dae-Seok;Chung Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.421-425
    • /
    • 2006
  • An ubiquitous healthcare system for the home care of elderly persons was designed and implemented using wireless sensor network technology. The wireless technology for home-care purpose gives new possibilities for monitoring of vital parameter with wearable biomedical sensors, and will give the patient the freedom to be mobile and still be under continuously monitoring and thereby to better quality of patient care. Emphasis is placed on recent advances in wireless ECG system for cardiac event monitoring with particular attention to arrhythmia detection in patient. This paper presents a diagnostic system for cardiac arrhythmias from ECG data, using wireless sensor technology. The system also provides an application for recording activities, events and potentially important medical symptoms. The hardware allows data to be transmitted wirelessly from on-body sensor to the base station and then to PC/PDA. Data is also transmitted to a back-end server for analysis using wireless internet connection. Experiments were conducted using the system for activity monitoring, exercise monitoring and medical screening tests and present preliminary data and results.

  • PDF

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

Development of an Ambulatory Wearable System for Continuous Patient Monitoring (휴대용 심전도 모니터링 계측 시스템 개발에 관한 연구)

  • Park, Chan-Won;Jeon, Chan-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.920-923
    • /
    • 2003
  • An wearable electrocardiogram (ECG) monitoring system is a widely used non-invasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we have a portable ECG monitoring system with conductive fiber which was characterized by the small-size and the low power consumption. The system consists of conductive fibers, one-chip microcontroller, ECG preprocessing circuit, and monitoring software to be able to record and analyze in PC. ECG preprocessing circuit is made of pre-amplifier with gain of 10, band-pass filter with bandwidth of 0.5-120Hz and 2.5V offset circuit for A/D conversion. ECG signals obtained by sensor are included with corrupted noises such as a baseline wandering, 60 Hz power noise and interference noise by body movement. For cancellation corrupted noises in signals obtained by conductive fiber, we used the wavelet decomposition of wavelet transforms in MATLAB toolbox.

  • PDF

Patient Flow Monitoring System based on Rheumatic Patient History Data (류머티스 환자 이력 데이터에 기반한 환자 플로우 모니터링 시스템)

  • Kim, Jun Woo;Lee, Sang Chul;Park, Sang Chan
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.10-19
    • /
    • 2014
  • In recent, hospital information systems are widely used to electronically record, manage and share the data collected in hospitals. Such systems have contributed greatly to improving the work efficiency in modern hospitals, however, the collected data concerning the patients should be appropriately processed and reused to provide the healthcare service providers with decision supports. Especially, this paper proposes the patient flow monitoring system for the operations management of the outpatient department for patients with chronic diseases, and discusses the related issues. The proposed system visualizes the standard process model extracted from the patient history data and various performance measures, and this enables the managers to evaluate and enhance the operations of the outpatient clinic. In this paper, the patient flow monitoring system is applied to the rheumatology clinic, and the prototype system optimized for I-pad is illustrated.

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Nam, Jae-Hyun;Chang, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.67-71
    • /
    • 2007
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, Sp02, and heart rate.

  • PDF

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Chang, Yong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1401-1407
    • /
    • 2008
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, SpO2, and heart rate.

Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현)

  • Kim, Dong-Hak;Kim, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF