• Title/Summary/Keyword: Patient's data

Search Result 2,903, Processing Time 0.032 seconds

Anti-Obesity Effect of Panax Ginseng in Animal Models: Study Protocol for a Systematic Review and Meta-Analysis (동물실험에서 인삼의 항비만 효과: 체계적 고찰과 메타분석을 위한 연구 프로토콜)

  • Cho, Jae-Heung;Kim, Koh-Woon;Park, Hye-Sung;Yoon, Ye-Ji;Song, Mi-Yeon
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2017
  • Recently the global epidemic problem of obesity has stimulated intense interest in the study of physiological mechanisms using animal models as a way to gain crucial data required for translation to human studies. Panax ginseng has been reported to have anti-obesity or antidiabetic effects in many animal studies; however, there have been few studies investigating human obesity. Herein, we will assess and examine the evidence supporting the anti-obesity effect of Panax ginseng in animal models with respect to anthropometric and metabolic outcomes. We will include controlled, comparative studies assessing the effect of Panax ginseng in preclinical studies of obesity. Panax ginseng will be administered during or following the induction of experimental obesity. The primary outcome measure will be anthropometric assessment and the secondary outcome measures will include adipose tissue weight, total amount of food consumed and metabolic parameters. We will search MEDLINE, Embase, PubMed, Web of Science, and Scopus without language, publication date, or other restrictions. Ethical approval will not be necessary as the data collected in this study will not be individual patient data, consequently there will be no concerns about violations of privacy. After finishing the whole procedure, the results will be disseminated by publication in a peer-reviewed journal or presented at a relevant conference. This protocol has been registered on the Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) website (http://www.camarades.info).

Tooth size and arch parameters of normal occlusion in a Iarge Korean sample (한국인 정상교합자의 치아크키와 치열궁 계측치에 관한 연구)

  • Lee, Shin-Jae;Moon, Seong-Cheol;Kim, Tae-Woo;Nahm, Dong-Seok;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.473-480
    • /
    • 2004
  • The aim of this study was to establish normative data on the tooth size and arch parameters of Koreans with normal occlusion, This study employed the dental casts of 296 (male: 179; female 117) normal occlusion samples, who were selected from 15,836 adults through a community dental health survey. The mesiodistal diameters of teeth, arch width, and arch length were measured by digital electronic calipers(accurate to 0.01 mm) and Bolton's indices as well as intermaxillary arch width ratios were calculated. In order to ensure reliability, intra- and inter-examiner error were evaluated. Although our dimensional data showed overt differences between genders, the indices and intermaxillary ratios evaluated were the same. The resultant data obtained were compared with the previous data to reveal whether any changes have occurred over the time. The clinical implication of the present findings was also discussed. This biometric study seemed to provide a clinically applicable diagnostic criteria for an individual malocclusion patient.

A COVID-19 Chest X-ray Reading Technique based on Deep Learning (딥 러닝 기반 코로나19 흉부 X선 판독 기법)

  • Ann, Kyung-Hee;Ohm, Seong-Yong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.789-795
    • /
    • 2020
  • Many deaths have been reported due to the worldwide pandemic of COVID-19. In order to prevent the further spread of COVID-19, it is necessary to quickly and accurately read images of suspected patients and take appropriate measures. To this end, this paper introduces a deep learning-based COVID-19 chest X-ray reading technique that can assist in image reading by providing medical staff whether a patient is infected. First of all, in order to learn the reading model, a sufficient dataset must be secured, but the currently provided COVID-19 open dataset does not have enough image data to ensure the accuracy of learning. Therefore, we solved the image data number imbalance problem that degrades AI learning performance by using a Stacked Generative Adversarial Network(StackGAN++). Next, the DenseNet-based classification model was trained using the augmented data set to develop the reading model. This classification model is a model for binary classification of normal chest X-ray and COVID-19 chest X-ray, and the performance of the model was evaluated using part of the actual image data as test data. Finally, the reliability of the model was secured by presenting the basis for judging the presence or absence of disease in the input image using Grad-CAM, one of the explainable artificial intelligence called XAI.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Improved Anatomical Landmark Detection Using Attention Modules and Geometric Data Augmentation in X-ray Images (어텐션 모듈과 기하학적 데이터 증강을 통한 X-ray 영상 내 해부학적 랜드마크 검출 성능 향상)

  • Lee, Hyo-Jeong;Ma, Se-Rie;Choi, Jang-Hwan
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.55-65
    • /
    • 2022
  • Recently, deep learning-based automated systems for identifying and detecting landmarks have been proposed. In order to train such a deep learning-based model without overfitting, a large amount of image and labeling data is required. Conventionally, an experienced reader manually identifies and labels landmarks in a patient's image. However, such measurement is not only expensive, but also has poor reproducibility, so the need for an automated labeling method has been raised. In addition, in the X-ray image, since various human tissues on the path through which the photons pass are displayed, it is difficult to identify the landmark compared to a general natural image or a 3D image modality image. In this study, we propose a geometric data augmentation technique that enables the generation of a large amount of labeling data in X-ray images. In addition, the optimal attention mechanism for landmark detection was presented through the implementation and application of various attention techniques to improve the detection performance of 16 major landmarks in the skull. Finally, among the major cranial landmarks, markers that ensure stable detection are derived, and these markers are expected to have high clinical application potential.

Medical Costs between Dietary Supplement Users and Non-users Using the Korea Health Panel Data (한국의료패널 자료를 활용한 건강기능식품 섭취에 따른 의료비 지출 비교분석)

  • Hye-Young Kwon;Soohyun Oh
    • Health Policy and Management
    • /
    • v.34 no.1
    • /
    • pp.87-93
    • /
    • 2024
  • Background: In recent years, studies have shown conflicting results regarding the benefits of dietary supplements in reducing healthcare expenditures. This study aimed to address this inconsistency by examining the association between supplement consumption and health expenditures using nationally representative data from the Korea Health Panel Survey (2019-2020). Methods: A 1:1 matched case-control dataset was established using propensity score matching technique based on supplement consumption. Then, total annual healthcare expenditures were compared between the two groups. In addition, a multivariate regression analysis (Proc Surveyreg) was performed to determine the association between the supplement consumption and medical costs. Results: The supplement user group spent about 1.72 million Korean won, while the non-user group spent about 1.43 million Korean won on medical services (p=0.0186). The results of multivariate regression showed that the costs were approximately 26.15% higher in the user group than in the non-user group (p=0.0004). Conclusion: Contrary to the previous studies that have shown the benefits of supplement use in reducing healthcare costs, this study showed that those who consistently consumed supplements spent more on medical services. This can be interpreted in the same context as previous studies suggesting that dietary supplement intake is a healthy behavior for managing one's health. However, we caution against drawing firm conclusions due to data limitations. Further analysis using patient-level epidemiologic data is needed.

Medium and Long-Term Data from a Series of 96 Endoscopic Transsphenoidal Surgeries for Cushing Disease

  • Buruc Erkan;Muhammed Bayindir;Ebubekir Akpinar;Osman Tanriverdi;Ozan Hasimoglu;Lutfi Sinasi Postalci;Didem Acarer Bugun;Dilara Tekin;Sema Ciftci;Ilkay Cakir;Meral Mert;Omur Gunaldi;Esra Hatipoglu
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.2
    • /
    • pp.237-248
    • /
    • 2024
  • Objective : Postoperative data on Cushing's disease (CD) are equivocal in the literature. These discrepancies may be attributed to different series with different criteria for remission and variable follow-up durations. Additional data from experienced centers may address these discrepancies. In this study, we present the results obtained from 96 endoscopic transsphenoidal surgeries (ETSSs) for CD conducted in a well-experienced center. Methods : Pre- and postoperative data of 96 ETSS in 87 patients with CD were included. All cases were handled by the same neurosurgical team between 2014 and 2022. We obtained data on remission status 3-6 months postoperatively (medium-term) and during the latest follow-up (long-term). Additionally, magnetic resonance imaging (MRI) and pathology results were obtained for each case. Results : The mean follow-up duration was 39.5±3.2 months. Medium and long-term remission rates were 77% and 82%, respectively. When only first-time operations were considered, the medium- and long-term remission rates were 78% and 82%, respectively. The recurrence rate in this series was 2.5%. Patients who showed remission between 3-6 months had higher long-term remission rates than did those without initial remission. Tumors >2 cm and extended tumor invasion of the cavernous sinus (Knosp 4) were associated with lower postoperative remission rates. Conclusion : Adenoma size and the presence/absence of cavernous sinus invasion on preopera-tive MRI may predict long-term postoperative remission. A tumor size of 2 cm may be a supporting criterion for predicting remission in Knosp 4 tumors. Further studies with larger patient populations are necessary to support this finding.

An Exploratory Study of Hospice Care to Patients with Advanced Cancer (암환자를 위한 호스피스 케어에 관한 탐색적 연구)

  • Park, Hye-Ja
    • The Korean Nurse
    • /
    • v.28 no.3
    • /
    • pp.52-67
    • /
    • 1989
  • True nursing care means total nursing care which includes physical, emotional and spiritual care. The modern nursing care has tendency to focus toward physical care and needs attention toward emotional and spiritual care. The total nursing care is mandatory for patients with terminal cancer and for this purpose, hospice care became emerged. Hospice case originated from the place or shelter for the travellers to Jerusalem in medieval stage. However, the meaning of modem hospice care became changed to total nursing care for dying patients. Modern hospice care has been developed in England, and spreaded to U.S.A. and Canada for the patients with terminal cancer. Nowaday, it became a part of nursing care and the concept of hospice care extended to the palliative care of the cancer patients. Recently, it was introduced to Korea and received attention as model of total nursing care. This study was attempted to assess the efficacy of hospice care. The purpose of this study was to prove a difference in terms of physical, emotional a d spiritual aspect between the group who received hospice care and who didn't receive hospice care. The subject for this study were 113 patients with advanced cancer who were hospitalized in the S different hospitals. 67 patients received hospice care in 4 different hospitals, and 46 patients didn't receive hospice care in another 4 different hospitals. The method of this study was the questionaire which was made through the descriptive study. The descriptive study was made by individual contact with 102 patients cf advanced cancer for 9 months period. The measurement tool for questionaire was made by author through the descriptive study, and included the personal religious orientation obtained from chung(originated R. Fleck) and 5 emotional stages before dying from Kubler Ross. The content ol questionaire consisted in 67 items which included 11 for general characteristics, 10 for related condition with cancer, 13 for wishes far physical therapy, 13 for emotional reactions and 20 for personal religious orientation. Data for this study was collected from Aug. 25 to Oct. 6 by author and 4 other nurse's who received education and training by author for the collection of data. The collected data were ana lysed using descriptive statistics, $X^2-test$, t-test and pearson correlation coefficient. Results of the study were as follows: "H.C Group" means the group of patient with cancer who received hospice care. "Non H.C Group" means the group of patient with cancer who did not receive hospice care. 1. There is a difference between H.C Group and Non H.C Group in term of the number of physical symptoms, subjective degree of pain sensation and pain control, subjective beliefs in physical cure, emotional reaction, help of present emotional and spiritual care from other personal, needs of emotional and spiritual care in future, selection of treatment method by patients and personal religious orientation. 2. The comparison of H.C Group and Non H.C Group 1) There is no difference in wishes for physical therapy between two groups(p=.522). Among Non H.C Group, a group, who didn't receive traditional therapy and herb medicine was higher than a group who received these in degree of belief that the traditional therapy and herb medicine can cure their disease, and this result was higher in comparison to H.C Group(p=.025, p=.050). 2) Non H.C Group was higher than H.C Group in degree of emotional reaction(p=.050). H.C Group was higher than Non H.C Group in denial and acceptant stage among 5 different emotional stages before dying described by Kubler Ross, especially among the patient who had disease more than 13 months(p=.0069, p=.0198). 3) Non H.C Group was higher than H. C Group in demanding more emotional and spiritual care to doctor, nurse, family and pastor(p=. 010). 4) Non H.C Group was higher than H.C Group in demanding more emotional and spiritual care to each individual of doctor, nurse and family (p=.0110, p=.0029, P=. 0053). 5) H.C Group was higher th2.n Non H.C Group in degree of intrinsic behavior orientation and intrinsic belief orientation of personal religious orientation(p=.034, p=.026). 6) In H.C Group and Non H.C Group, the degree of emotional demanding of christians was significantly higher than non christians to doctor, nurse, family and pastor(p=. 000, p=.035). 7) In H.C Group there were significant positive correlations as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and: the degree of intrinsic behavior orientation in personal religious orientation(r=. 5512, p=.000). (2) Between the degree of emotional demandings to doctor, nurse. family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.4795, p=.000). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic: belief orientation in personal religious orientation(r=.8986, p=.000). (4) Between the degree of extrinsic religious orientation and the degree of consensus religious orientation in personal religious orientation (r=. 2640, p=.015). In H.C. Group there were significant negative correlations as following; (1) Between the degree of intrinsic behavior orientation and extrinsic religious orientation in personal religious orientation (r=-.4218, p=.000). (2) Between the degree or intrinsic behavior orientation and consensus religious orientation in personal religious orientation(r=-. 4597, p=.000). (3) Between the degree of intrinsic belief orientations and the degree of extrinsic religious orientation in personal religious orientation(r=-.4388, p=.000). (4) Between the degree of intrinsic belief orientation and the degree of consensus religious orientation in personal religious orientation(r=-. 5424, p=.000). 8) In Non H.C Group there were significant positive correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic behavior orientation in personal religious orientation(r= .3566, p=.007). (2) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of intrinsic belief orientation in personal religious orientation(r=.3430, p=.010). (3) Between the degree of intrinsic behavior orientation and the degree of intrinsic belief orientation in personal religious orientation(r=.9723, p=.000). In Non H.C Group there were significant negative correlation as following; (1) Between the degree of emotional demandings to doctor, nurse, family & pastor and the degree of extrinsic religious orientation in personal religious orientation(r= -.2862, p=.027). (2) Between the degree of intrinsic behavior orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5083, p=.000). (3) Between the degree of intrinsic belief orientation and the degree of extrinsic religious orientation in personal religious orientation(r=-. 5013, p=.000). In conclusion above datas suggest that hospice care provide effective total nursing care for the patients with terminal cancer, and hospice care is mandatory in all medical institutions.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

The evaluate the usefulness of various CT kernel applications by PET/CT attenuation correction (PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가)

  • Lee, Jae-Young;Seong, Yong-Jun;Yoon, Seok-Hwan;Park, Chan-Rok;Lee, Hong-Jae;Noh, Kyung-Wun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.37-43
    • /
    • 2017
  • Purpose Recently PET/CT image's attenuation correction is used CTAC(Computed Tomgraphy Attenuation Correction). it can quantitative evaluation by SUV(Standard Uptake Value). This study's purpose is to evaluate SUV and to find proper CT kernel using CTAC with applied various CT kernel to PET/CT construction. Materials and Methods Biograph mCT 64 was used for the equipment. We were performed on 20 patients who had examed at our hospital from february through March 2017. Using NEMA IEC Body Phantom, The data was reconstructed PET/CT images with CTAC appiled various CT kernel. ANOVA was used to evaluated the significant difference in the result. Results The result of measuring the radioactivity concentration of Phantom was B45F 96% and B80F 6.58% against B08F CT kernel, each respectively. the SUVmax increased to B45F 0.86% and B80F 6.54% against B08F CT kernel, In case of patient's parts data, the Lung SUVmax increased to B45F 1.6% and B80F 6.6%, Liver SUVmax increased to B45F 0.7% and B80F 4.7%, and Bone SUVmax increased to B45F 1.3% and B80F 6.2%, respectively. As for parts of patient's about Standard Deviation(SD), the Lung SD increased to B45F 4.2% and B80F 15.4%, Liver SD increased to B45F 2.1% and B80F 11%, and Bone SD increased to B45F 2.3% and B80F 14.7%, respectively. There was no significant difference discovered in three CT kernel (P >.05). Conclusion When using increased noise CT kernel for PET/CT reconstruction, It tends to change both SUVmax and SD in ROI(region of interest), Due to the increase the CT kernel number, Sharp noise increased in ROI. so SUVmax and SD were highly measured, but there was no statistically significant difference. Therefore Using CT kernel of low variation of SD occur less variation of SUV.

  • PDF