• Title/Summary/Keyword: Passive Vibration Control

Search Result 346, Processing Time 0.026 seconds

Vibration Characteristics and Tension Control of a Wire in WEDM (와이어 방전가공기용 와이어의 진동 특성과 장력 변동 저감을 위한 연구)

  • Chae, Ho-Jung;Lee, Seung-Yeop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.86-92
    • /
    • 2001
  • Vibrational characteristics and tension fluctuation of a translating wire in WEDM are the main problems to deteriorate the cutting accuracy and processing performance. In this paper, we analyze natural frequencies of the wire used in WEDM, both theoretically and experimentally. To reduce the tension variation of the wire, which directly affects cutting performance, we have designed a simply tension reduction device using springs and rollers. It is shown that tension fluctuation is reduced about 35% using the passive tension controller.

  • PDF

Swing Motion Analysis of the Container Crane Headblock (콘테이너 크레인의 헤드블록 횡동요 해석)

  • 조대승
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.765-772
    • /
    • 1997
  • This paper presents the swing motion analysis of the container crane headblock with the passive control device using hydraulic motors and anti-swing ropes. The device hauls at the headblock to opposite direction of its swing motion using the tension difference between anti-swing ropes connected to the headblock. To consider this control mechanism, the headblock is modelled as the rigid bar suspended by two hoist ropes at the overhead trolley and its non-linear equation of motion is derived using Lagrange's equation. Some numerical experiments using the equation are carried out to investigate the swing motion characteristics of the headblock under the variation of geometric relation among the cargo handling components and to evaluate the performance of the anti-swing device.

  • PDF

Innovative modeling of tuned liquid column damper controlled structures

  • Di Matteo, Alberto;Di Paola, Mario;Pirrotta, Antonina
    • Smart Structures and Systems
    • /
    • v.18 no.1
    • /
    • pp.117-138
    • /
    • 2016
  • In this paper a different formulation for the response of structural systems controlled by Tuned Liquid Column Damper (TLCD) devices is developed, based on the mathematical tool of fractional calculus. Although the increasing use of these devices for structural vibration control, it has been demonstrated that existing model may lead to inaccurate prediction of liquid motion, thus reflecting in a possible imprecise description of the structural response. For this reason the recently proposed fractional formulation introduced to model liquid displacements in TLCD devices, is here extended to deal with TLCD controlled structures under base excitations. As demonstrated through an extensive experimental analysis, the proposed model can accurately capture structural responses both in time and in frequency domain. Further, the proposed fractional formulation is linear, hence making identification of the involved parameters extremely easier.

Optimal placement of MR dampers for 20-story nonlinear benchmark building (20층 비선형 벤치마크 빌딩에 대한 MR 유체 감쇠기의 최적위치 결정)

  • 장종우;조상원;윤우현;이인원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.153-160
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effective-ness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for M dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor are. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et al. 2000, 2002). Passive On/on algorithms are used in order to represent the control algorithm of M dampers.

  • PDF

Mitigation of motions of tall buildings with specific examples of recent applications

  • Kareem, Ahsan;Kijewski, Tracy;Tamura, Yukio
    • Wind and Structures
    • /
    • v.2 no.3
    • /
    • pp.201-251
    • /
    • 1999
  • Flexible structures may experience excessive levels of vibration under the action of wind, adversely affecting serviceability and occupant comfort. To ensure the functional performance of a structure, various design modifications are possible, ranging from alternative structural systems to the utilization of passive and active control devices. This paper presents an overview of state-of-the-art measures that reduce the structural response of buildings, including a summary of recent work in aerodynamic tailoring and a discussion of auxiliary damping devices for mitigating the wind-induced motion of structures. In addition, some discussion of the application of such devices to improve structural resistance to seismic events is also presented, concluding with detailed examples of the application of auxiliary damping devices in Australia, Canada, China, Japan, and the United States.

Optimal placement of MR dampers for 20-story nonlinear benchmark building (20층 비선형 벤치마크 빌딩에 대한 자기유변유체 감쇠기의 최적위치 결정)

  • 장종우;조상원;이인원;윤우현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.467-472
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effectiveness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for MR dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor we. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et at. 2000, 2002). Passive On/Off algorithms are used in order to represent the control algorithm of MR dampers.

  • PDF

Optimal assessment and location of tuned mass dampers for seismic response control of a plan-asymmetrical building

  • Desu, Nagendra Babu;Dutta, Anjan;Deb, S.K.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.4
    • /
    • pp.459-477
    • /
    • 2007
  • A bi-directional tuned mass damper (BTMD) in which a mass connected by two translational springs and two viscous dampers in two orthogonal directions has been introduced to control coupled lateral and torsional vibrations of asymmetric building. An efficient control strategy has been presented in this context to control displacements as well as acceleration responses of asymmetric buildings having asymmetry in both plan and elevation. The building is idealized as a simplified 3D model with two translational and a rotational degrees of freedom for each floor. The principles of rigid body transformation have been incorporated to account for eccentricity between center of mass and center of rigidity. The effective and robust design of BTMD for controlling the vibrations in structures has been presented. The redundancy of optimum design has been checked. Non dominated sorting genetic algorithm (NSGA) has been used for tuning optimum stages and locations of BTMDs and its parameters for control of vibration of seismically excited buildings. The optimal locations have been observed to be reasonably compact and practically implementable.

Shaking table test of pounding tuned mass damper (PTMD) on a frame structure under earthquake excitation

  • Lin, Wei;Wang, Qiuzhang;Li, Jun;Chen, Shanghong;Qi, Ai
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.545-553
    • /
    • 2017
  • A pounding tuned mass damper (PTMD) can be considered as a passive device, which combines the merits of a traditional tuned mass damper (TMD) and a collision damper. A recent analytical study by the authors demonstrated that the PTMD base on the energy dissipation during impact is able to achieve better control effectiveness over the traditional TMD. In this paper, a PTMD prototype is manufactured and applied for seismic response reduction to examine its efficacy. A series of shaking table tests is conducted in a three-story building frame model under single-dimensional and two-dimensional broadband earthquake excitations with different excitation intensities. The ability of the PTMD to reduce the structural responses is experimentally investigated. The results show that the traditional TMD is sensitive to input excitations, while the PTMD mostly has improved control performance over the TMD to remarkably reduce both the peak and root-mean-square (RMS) structural responses under single-dimensional earthquake excitation. Unlike the TMD, the PTMD is found to have the merit of maintaining a stable performance when subjected to different earthquake loadings. In addition, it is also indicated that the performance of the PTMD can be enhanced by adjusting the initial gap value, and the control effectiveness improves with the increasing excitation intensity. Under two-dimensional earthquake inputs, the PTMD controls remain outperform the TMD controls; however, the oscillation of the added mass is observed during the test, which may induce torsional vibration modes of the structure, and hence, result in poor control performance especially after a strong earthquake period.

Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag (Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템)

  • Hwang, Inho;Park, Jun Hyung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.657-664
    • /
    • 2008
  • Rain-wind induced cable vibration can cause the damages in the cable-stayed bridge due to very little inherent damping characteristics and low fundamental frequency. External Dampers attached to stay cables near anchorages have been shown to be effective means at short stay-cables. However, installation locations of external dampers are limited to a particular range due to aesthetic and practical reasons for very long stay-cables. A recent study by the authors showed that the stay-cable vibration system can perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges. This paper extends the previous study on the taut string representation of the cable by adding cable sag and inclination. The response of the proposed system compared to those of the cable with and without an external damper, and the movable anchorage system provides very effective mitigation of cable vibration. Cable damping ratio is seen to be remarkably reduced by movable anchorage system for a wide range of cable sag. This result shows that the sag effects of the proposed system should be considered.

Seismic control of offshore platform using artificial neural network (인공신경망을 이용한 해양구조물의 지진시 진동제어)

  • Kim, Dong Hyawn;Kim, Ju Myung;Shim, Jae Seol
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.175-181
    • /
    • 2009
  • An intelligent control technique using a neural network is proposed for offshore structures exposed to sea-bed earthquakes. Fluid-structure interaction effect was considered in developing controller and a training algorithm for the neural network is presented. In the numerical example, the performance of the proposed neural network controller was compared with that of a passive controller and uncontrolled structures. Based on the example, it can be concluded that the proposed neuro-control scheme can be used for offshore structures with nonlinear characteristics due to its interaction with fluid.