DOI QR코드

DOI QR Code

Shaking table test of pounding tuned mass damper (PTMD) on a frame structure under earthquake excitation

  • Lin, Wei (School of Civil Engineering, Fuzhou University) ;
  • Wang, Qiuzhang (School of Civil Engineering, Fuzhou University) ;
  • Li, Jun (Centre for Infrastructural Monitoring and Protection, School of Civil and Mechanical Engineering, Curtin University) ;
  • Chen, Shanghong (School of Civil Engineering, Fuzhou University) ;
  • Qi, Ai (School of Civil Engineering, Fuzhou University)
  • Received : 2017.07.25
  • Accepted : 2017.08.19
  • Published : 2017.11.25

Abstract

A pounding tuned mass damper (PTMD) can be considered as a passive device, which combines the merits of a traditional tuned mass damper (TMD) and a collision damper. A recent analytical study by the authors demonstrated that the PTMD base on the energy dissipation during impact is able to achieve better control effectiveness over the traditional TMD. In this paper, a PTMD prototype is manufactured and applied for seismic response reduction to examine its efficacy. A series of shaking table tests is conducted in a three-story building frame model under single-dimensional and two-dimensional broadband earthquake excitations with different excitation intensities. The ability of the PTMD to reduce the structural responses is experimentally investigated. The results show that the traditional TMD is sensitive to input excitations, while the PTMD mostly has improved control performance over the TMD to remarkably reduce both the peak and root-mean-square (RMS) structural responses under single-dimensional earthquake excitation. Unlike the TMD, the PTMD is found to have the merit of maintaining a stable performance when subjected to different earthquake loadings. In addition, it is also indicated that the performance of the PTMD can be enhanced by adjusting the initial gap value, and the control effectiveness improves with the increasing excitation intensity. Under two-dimensional earthquake inputs, the PTMD controls remain outperform the TMD controls; however, the oscillation of the added mass is observed during the test, which may induce torsional vibration modes of the structure, and hence, result in poor control performance especially after a strong earthquake period.

Keywords

Acknowledgement

Supported by : National Natural Science Foundation of China

References

  1. Casado, C.M., Poncela, A.V. and Lorenzana, A. (2007), "Adaptive tuned mass damper for the construction of concrete piers", Struct. Eng., 17(3), 252-255.
  2. Chen, S.H., Lin, W., Yu, J.X. and Qi, A. (2014), "Free-interface modal synthesis based substructural damage detection method", Shock Vibr.
  3. Eason, R.P., Sun, C., Dick, A.J. and Nagarajaiah, S. (2013), "Attenuation of a linear oscillator using a nonlinear and a semiactive tuned mass damper in series", J. Sound Vibr., 332(1), 154-166. https://doi.org/10.1016/j.jsv.2012.07.048
  4. Inaudi, J.A. and Kelly, J.M. (1995), "Mass damper using frictiondissipating devices", J. Eng. Mech., 121(1), 142-149. https://doi.org/10.1061/(ASCE)0733-9399(1995)121:1(142)
  5. Kawaguchi, A., Teramura, A. and Omote, Y. (1992), "Time history response of a tall building with a tuned mass damper under wind force", J. Wind Eng. Industr. Aerodyn., 43(1), 1949-1960. https://doi.org/10.1016/0167-6105(92)90619-L
  6. Lee, C.L., Chen, Y.T., Chung, L.L. and Wang, Y.P. (2006), "Optimal design theories and applications of tuned mass dampers", Eng. Struct., 28(1), 43-53. https://doi.org/10.1016/j.engstruct.2005.06.023
  7. Li, H.N., Yi, T.H., Ming, G.U. and Huo, L.S. (2009), "Evaluation of earthquake-induced structural damages by wavelet transform", Progr. Nat. Sci., 19(4), 461-470. https://doi.org/10.1016/j.pnsc.2008.09.002
  8. Li, J. and Hao, H. (2016), "A review of recent research advances on structural health monitoring in Western Australia", Struct. Monitor. Mainten., 3(1), 33-49. https://doi.org/10.12989/smm.2016.3.1.033
  9. Lin, G.L., Lin, C.C., Chen, B.C. and Soong, T.T. (2015), "Vibration control performance of tuned mass dampers with resettable variable stiffness", Eng. Struct., 83, 187-197. https://doi.org/10.1016/j.engstruct.2014.10.041
  10. Lin, W., Chen, S.H., Yu, J.X. and Qi, A. (2013), "Seismic behavior of long-span connected structures under multi-supported and multi-dimensional earthquake excitations", Adv. Struct. Eng., 16(9), 1579-1586. https://doi.org/10.1260/1369-4332.16.9.1579
  11. Lin, W., Lin, Y., Song, G. and Li, J. (2016), "Multiple pounding tuned mass damper (MPTMD) control on benchmark tower subjected to earthquake excitations", Earthq. Struct., 11(6), 1123-1141. https://doi.org/10.12989/eas.2016.11.6.1123
  12. Lin, W., Song, G.B. and Chen, S.H. (2017), "PTMD control on a benchmark TV tower under earthquake and wind load excitations", Appl. Sci., 7(4), 7040425.
  13. Lu, X., Zhang, Q., Weng, D., Zhou, Z., Wang, S., Mahin, S.A. and Qian, F. (2017), "Improving performance of a super tall building using a new eddy-current tuned mass damper", Struct. Contr. Health Monitor., 24(3).
  14. Nagarajaiah, S. (2009), "Adaptive passive, semiactive, smart tuned mass dampers: identification and control using empirical mode decomposition, hilbert transform, and short-term fourier transform", Struct. Contr. Health Monitor., 16(7-8), 800-841. https://doi.org/10.1002/stc.349
  15. Occhiuzzi, A., Spizzuoco, M. and Ricciardelli, F. (2008), "Loading models and response control of footbridges excited by running pedestrians", Struct. Contr. Health Monitor., 15(3), 349-368. https://doi.org/10.1002/stc.248
  16. Ricciardelli, F., Occhiuzzi, A. and Clemente, P. (2000), "Semiactive tuned mass damper control strategy for wind-excited structures", J. Wind Eng. Industr. Aerodyn., 88(1), 57-74. https://doi.org/10.1016/S0167-6105(00)00024-6
  17. Roberto, V. (1994), "Seismic control of structures with resonant appendages", Proceedings of the 1st World Conference on Structural Control, Los Angeles, California, U.S.A.
  18. Roberto, V. and Scott, C.M. (1995), "Passive seismic control of cable-stayed bridges with damped resonant appendages", Earthq. Eng. Struct. Dyn., 24(2), 233-246. https://doi.org/10.1002/eqe.4290240208
  19. Song, G.B., Zhang, P., Li, L.Y., Singla, M., Patil, D., Li, H.N. and Mo, Y.L. (2016), "Vibration control of a pipeline structure using pounding tuned mass damper", J. Eng. Mech., 142(6), 04016031. https://doi.org/10.1061/(ASCE)EM.1943-7889.0001078
  20. Soong, T.T. and Spencer Jr, B.F. (2002), "Supplemental energy dissipation: State-of-the-art and state-of-the-practice", Eng. Struct., 24(3), 243-259. https://doi.org/10.1016/S0141-0296(01)00092-X
  21. Tubino, F. and Piccardo, G. (2015), "Tuned mass damper optimization for the mitigation of human-induced vibrations of pedestrian bridges", Meccan., 50(3), 809-824. https://doi.org/10.1007/s11012-014-0021-z
  22. Varadarajan, N. and Nagarajaiah, S. (2004), "Wind response control of building with variable stiffness tuned mass damper using empirical mode decomposition/hilbert transform", J. Eng. Mech., 130(4), 451-458. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(451)
  23. Weber, B. and Feltrin, G. (2010), "Assessment of long-term behavior of tuned mass dampers by system identification", Eng. Struct., 32(11), 3670-3682. https://doi.org/10.1016/j.engstruct.2010.08.011
  24. Weber, F., Distl, H., Fischer, S. and Braun, C. (2016), "MR damper controlled vibration absorber for enhanced mitigation of harmonic vibrations", Appl. Sci., 5(4), 5040027.
  25. Xiang, P. and Nishitani, A. (2014), "Seismic vibration control of building structures with multiple tuned mass damper floors integrated", Earthq. Eng. Struct. Dyn., 43(6), 909-925. https://doi.org/10.1002/eqe.2379
  26. Xu, Y.L., Samali, B. and Kwok, K.C.S. (1992), "Control of alongwind response of structures by mass and liquid dampers", J. Eng. Mech., 118(1), 20-39. https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)
  27. Yi, T.H., Li, H.N. and Sun H.M. (2013), "Multi-stage structural damage diagnosis method based on "energy-damage" theory", Smart Struct. Syst., 12(3-4), 345-361. https://doi.org/10.12989/sss.2013.12.3_4.345
  28. Yi, T.H., Li, H.N. and Zhang, X.D. (2015), "Health monitoring sensor placement optimization for canton tower using immune monkey algorithm", Struct. Contr. Health Monitor., 22(1), 123-138. https://doi.org/10.1002/stc.1664
  29. Zhang, P., Song, G., Li, H.N. and Lin, Y.X. (2012), "Seismic control of power transmission tower using pounding TMD", J. Eng. Mech., 139(10), 1395-1406.
  30. Zhang, Z. and Ou, J.P. (2017), "Optimization design of coupling beam metal damper in shear wall structures", Appl. Sci., 7(2), 7020137.

Cited by

  1. Seismic Vibration Mitigation of a Cable-Stayed Bridge with Asymmetric Pounding Tuned Mass Damper vol.2021, pp.None, 2021, https://doi.org/10.1155/2021/6647303