• Title/Summary/Keyword: Particle Counter

Search Result 211, Processing Time 0.03 seconds

Intercomparison of Number Concentrations by CPCs using Generated Particles in Chamber (챔버 내 발생 입자를 이용한 CPC 수농도 비교 평가)

  • Bae, Min-Suk;Park, Da-Jeong;Park, Seung-Shik;Chen, Wei-Nai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.619-630
    • /
    • 2014
  • Two butanol-based Condensation Particle Counters (CPC 3022, CPC 3025), three water-based CPCs (CPC3781, CPC3785${\times}$2), a Gardner Counter, a Fast Mobility Particle Sizer (FMPS), and an Aerosol Electrometer (AE) were deployed to measure the number concentrations from atomized aerosol under six different conditions. Comparisons of particle number concentrations measured by the CPCs, FMPS, and AE were conducted to evaluate the performance of the each CPCs using laboratory generated artificial particles such as NaCl, succinic acid ($C_4H_6O_4$), and particles generated by propane torch & heat gun in the chamber. Good correlation between the CPC3025 and FMPS was observed for the total particle number concentrations in the size range 15 nm to 90 nm. In addition, this paper suggests that photometric mode in water-based CPC3785 could not be used as quantitative of number concentrations for CPC3785.

Applicability of Optical Particle Counters for Measurement of Airborne Pesticide Spray Drift (공기 중 농약 비산의 측정을 위한 광학 입자 측정기의 적용성 평가)

  • Kim, Rack-Woo;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.79-87
    • /
    • 2019
  • With desires for safe food, there is growing concern that pesticide spray drift will expose people, plants, and the environment to pesticide residue and potential negative effects thereof. For highly efficient, safe spray application, technologies for measuring the spray drift should be developed and improved with some urgency. This study investigated the applicability of two optical particle counters (OPCs), which are mostly used to measure airborne particle mass concentration, for measurement of airborne pesticide spray drift. Experiments were conducted in a controlled laboratory and an ash tree orchard to evaluate the handiness and accuracy of two OPCs, OPC 1 and OPC 2. The experimental results indicated that the OPC 1 was better applicable to the measurement of spray drift in the field while the use of the OPC 2 was limited due to its narrow range of measurable droplet sizes. The readings of the OPC 1 produced highly accurate results ($R^2=0.9637$) compared to the actual spray drift. For better application of OPCs, this study suggests the OPCs should be positioned properly to inhale spray droplets of the appropriate size and concentration.

Effect of Disk Rotational Speed on Contamination Nano Particles Generated in a Hard Disk Drive (하드 디스크 드라이브 회전수 변화가 드라이브 내 나노 오염 입자 발생에 미치는 영향)

  • Lee, Dae-Young;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.976-983
    • /
    • 2004
  • In high-density hard disk drives, the slider should be made to fly close to the magnetic recording disk to generate better signal resolution and at an increasingly high velocity to achieve better data rate. The slider disk interaction in CSS (contact-start-stop) mode is an important source of particle generation. Contamination particles in the hard disk drive can cause serious problems including slider crash and thermal asperities. We investigated the number and the sizes of particles generated in the hard disk drive, operating at increasing disk rotational speeds, in the CSS mode. CNC (condensation nucleus counter) and PSS (particle size selector) were used for this investigation. In addition, we examined the particle components by using SEM (scanning electron microscopes), AES (auger electron spectroscopy), and TOF-SIMS (time of flight-secondary ions mass spectrometry). The increasing disk rotational speed directly affected the particle generation by slider disk interaction. The number of particles that were generated increased with the disk rotational speed. The particle generation rate increased rapidly at motor speeds above 8000 rpm. This increase may be due to the increased slider disk interaction. Particle sizes ranged from 14 to 200 nm. The particles generated by slider disk interaction came from the lubricant on the disk, coating layer of the disk, and also slider surface.

Coal particle distribution inside fuel droplets of high loading CWM (고부하도 CWM 연료방울안에 존재하는 미분탄 분포)

  • 김성준;유영길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.618-629
    • /
    • 1991
  • The purpose of this experiment is to understand the distribution of coal particles inside CWM droplet which is believed to be a very important factor controlling the flame stability. CWM slurry is atomized by an air assisted twin fluid nozzle. An experimental rig is designed and fabricated. The mean size of coal particle distribution in CWM slurry, atomizing air pressure, coal particle loading in slurry and sampling position inside spray are main experimental variables. The atomized CWM droplets are sampled on the thin white layer of magnesium oxide by the emergency sampling shutter. The sampled coal particles on magnesium oxide layers are collected into test tubes and dispersed completely by Ultra-Sonicator. The size distribution of coal particles inside droplets are measured by Coulter Counter. The presence of coal particle inside the impressions of droplets on magnesium oxide layer are investigated by photo technique. There are quite many droplets which do not have any coal particles. Those are just water droplets, not CWM droplets. The population ratio of droplets without coal particles to toal number of droplets is strongly affected by the mean size of coal particle distribution in slurry and this ration becomes bigger number as the mean size of coal particles be larger. The size distribution of coal particles inside CWM droplets is not even and depends on the size of droplet. Experimental results show that the larger CWM droplets has droplets has bigger mean value of particle size distribution. This trend becomes more evident as the atomizing air pressure is raised and the mean size of coal particles in CWM slurry is bigger. That is, the distribution of coal particles inside CWM dropolets is very much affected by the atomizing air pressure and the mean size of pulverized coal particles in CWM slurry.

Preliminary Study on the Cloud Condensation Nuclei (CCN) Activation of Soot Particles by a Laboratory-scale Model Experiments

  • Ma, Chang-Jin;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.175-183
    • /
    • 2014
  • To visually and chemically verify the rainout of soot particles, a model experiment was carried out with the cylindrical chamber (0.2 m (D) and 4 m (H)) installing a cloud drop generator, a hydrotherometer, a particle counter, a drop collector, a diffusing drier, and an artificial soot particle distributer. The processes of the model experiment were as follows; generating artificial cloud droplets (major drop size : $12-14{\mu}m$) until supersaturation reach at 0.52%-nebulizing of soot particles (JIS Z 8901) with an average size of $0.5{\mu}m$-counting cloud condensation nuclei (CCN) particles and droplets by OPC and the fixation method (Ma et al., 2011; Carter and Hasegawa, 1975), respectively - collecting of individual cloud drops - observation of individual cloud drops by SEM - chemical identifying of residual particle in each individual droplet by SEM-EDX. After 10 minutes of the completion of soot particle inject, the number concentrations of PM of all sizes (> $0.3{\mu}m$) dramatically decreased. The time required to return to the initial conditions, i.e., the time needed to CCN activation for the fed soot particles was about 40 minutes for the PM sized from $0.3-2.0{\mu}m$. The EDX spectra of residual particles left at the center of individual droplet after evaporation suggest that the soot particles seeded into our experimental chamber obviously acted as CCN. The coexistence of soot and mineral particle in single droplet was probably due to the coalescence of droplets (i.e., two droplets embodying different particles (in here, soot and background mineral particles) were coalesced) or the particle capture by a droplet in our CCN chamber.

Characteristics of Size Resolved Atmospheric Aerosol in Seoul, 2001 using OPC measurement (광학적 입자계수기를 이용한 2001년 서울 에어로졸의 크기별 물리 특성)

  • 정창훈;전영신;최병철
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.434-435
    • /
    • 2002
  • 에어로졸 입자의 크기 분포를 측정하는: 방법은 여러 가지가 있다. 이중 광학 입자계수기(Optical Particle Counter)는 직경 0.3-25$\mu\textrm{m}$의 입자의 산란광의 강도를 측정하여 입자의 크기별 개수를 측정하는 기기로 청정지역의 대기 중 부유하는 입자의 측정에 널리 사용되고 있다 (전영신 등, 1999). 본 연구에서는 기상청 기상연구소에서 측정한 광i부 입자계수기(HYAC/ROYCO 5230)의 측정자료를 이용하여 2001년도 1년간 서울의 대기 에어로졸의 특성과 경향을 분석하였다. 측정결과는 대기환경월보(환경부, 2001) (중략)

  • PDF

Nature of Surface and Bulk Defects Induced by Epitaxial Growth in Epitaxial Layer Transfer Wafers

  • Kim, Suk-Goo;Park, Jea-Gun;Paik, Un-Gyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.143-147
    • /
    • 2004
  • Surface defects and bulk defects on SOI wafers are studied. Two new metrologies have been proposed to characterize surface and bulk defects in epitaxial layer transfer (ELTRAN) wafers. They included the following: i) laser scattering particle counter and coordinated atomic force microscopy (AFM) and Cu-decoration for defect isolation and ii) cross-sectional transmission electron microscope (TEM) foil preparation using focused ion beam (FIB) and TEM investigation for defect morphology observation. The size of defect is 7.29 urn by AFM analysis, the density of defect is 0.36 /cm$^2$ at as-direct surface oxide defect (DSOD), 2.52 /cm$^2$ at ox-DSOD. A hole was formed locally without either the silicon or the buried oxide layer (Square Defect) in surface defect. Most of surface defects in ELTRAN wafers originate from particle on the porous silicon.

Identification of the three-dimensional topology of hairpin packet structures in turbulent boundary layers (난류경계층의 헤어핀 다발구조에 대한 3차원 토폴로지 규명)

  • Kwon, Seong-Hoon;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.610-615
    • /
    • 2003
  • This experiment has been carried out to find the structure of turbulent boundary layer with instantaneous velocity fields obtained in stream-wall-normal planes using a stereo-PIV (Particle Image Velocimetry) method. And it has been measured perpendicular plane and horizontal plane with hairpin vortex structure by Reynolds number change and made third dimension shape for section of horizontal plane through stereo-PIV. In the outer layer hairpin vortices occur in streamwise-aligned packets that propagate with small velocity dispersion. A streaky structure is composed of counter-rotating vortex. According as y+ increases, streaky structure's interval space decrease, and it shows that hairpin shape of prior research is vertified. The objective of the present research is to gain a better understanding of coherent structures in the outer of wall turbulence by experimentally examining coherent structures.

  • PDF

An Experimental Study for the Structure of Conical Vortex at the Low-Rise Building Roof by using a PIV Technique (PIV기법을 이용한 저층 건물 지붕에서 발생되는 원추형 와의 구조에 대한 실험적 연구)

  • Ji, Ho-Seong;Jeong, Eun-Ho;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.667-672
    • /
    • 2000
  • The Characteristics of the conical vortices on the roof surface of a low-rise building has been investigated by using a PIV(Particle Image Velocimerty) technique. The scaled model of TTU building with 1:92 scaling ratio was used. The Reynolds number based on the free stream velocity and the length of the model was $1.96{\times}10^5$. When the angle of attack for the building model is $45^{\circ}$, the conical vortices are occurred symmetrically and the center of vortices are changed with respect to the angle of the approaching flow. The rotating direction of the conical vortices found to be counter-rotating. The secondary vortex motions are investigated using the instantaneous flow field data.

  • PDF

Fluid Flow and Heat Transfer in the Fluidized Bed Heat Exchanger (순환 유동층 열교환기내 유체유동과 열전달)

  • 김원철;배성택;이병창;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the fouling increases the pressure loss and degrades the thermal Performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The Present work showed that the flow velocity range for Possible collision between the tube wall and the particles was higher with heavier density solid particles. in audition. the solid particle periodically hitting the tube wall broke the thermal boundary laver. and increased the rate of heat transfer.