장방형 압전세라믹변압기의 전극형상이 전기적특성에 미치는 영향 (Effect of Electrodes on the Electrical Properties of Piezoelectric Ceramic Transformer)

  • 정수태;최상수;조상희
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권6호
    • /
    • pp.562-569
    • /
    • 1997
  • The resonance characteristics on vibration mode of a transverse type ceramic resonator and the output voltage characteristics of a piezoelectric ceramic transformer are discussed in the effects of partial electrode arrangement (one sided, centered and both sided). A resonance characteristics of resonator depended strongly on both a vibration mode and a electrode structure because of a strain distribution. The maximum resonance current of a piezoelectric ceramic transformer [PCT] with partial centered electrode appeared in λ/2 mode, and that of a PCT with partial both sided electrode appeared in 3λ/2 mode. But the maximum output voltage of those samples appeared in λ/2 mode. In the PCT with partial both sided electrode, the ration of output voltage to input current was highest out of all samples and the poling voltage was a half times of 깬두 type transformer.

  • PDF

음향파 공명 산란의 새로운 해석방법 (A New Method for Extracting Resonance Information in Acoustic Wave Resonance Scattering)

  • 이희남;박영진
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.409-417
    • /
    • 1999
  • A new method is proposed for the isolation of resonances from scattered waves for the isolaton of resonances from scattered waves for acoustic wave resonance scattering problems. The resonance scattering function consisting purely of resonance information is defined. Acoustic wave scattering from a variety of submerged bodies is numerically analyzed. The classical resonance scattering theory (RST) and the new method compute identical magnitudes of the resonances from each partial wave, however, the phases are significantly different. The exact $\pi$-radians phase shifts through the resonance and anti-resonance frequencies show that the proposed method properly extracts the vibrational resonance information of the scatterer. Due to the differences in phases of the resonances from each partial wave, the new method and RST generate different total resonance spectra.

  • PDF

음향파 공명 산란의 새로운 해석방법 (A new method for extracting resonance information in acoustic wave resonance scattering)

  • 이희남;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.504-509
    • /
    • 1998
  • A new method is proposed for the isolation of resonances from scattered waves for acoustic wave resonance scattering problems. The resonance scattering function consisting purely of resonance information is defined. Acoustic wave scattering from a variety of submerged bodies is numerically analyzed. The classical resonance scattering theory (RST) and the new method compute identical magnitude of the resonance from each scattered partial wave, however, the phases are significantly different. The exact .pi.-radians phase shifts through the resonance and anti-resonance show that the proposed method properly extracts the vibrational resonance information of the scatterer. Due to the difference in the phase of each, partial wave, the new method and RST generate different total resonance spectra.

  • PDF

Seeding Metastasis of Chromophobe Renal Cell Carcinoma after Robot-Assisted Laparoscopic Partial Nephrectomy

  • Lee, Kanghun;Choi, Moon Hyung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.119-124
    • /
    • 2017
  • Chromophobe renal cell carcinoma (RCC) is an uncommon subtype of RCC having a better prognosis than clear cell RCC. Although there are several reports of seeding metastasis of RCC after biopsy, seeding metastasis of chromophobe RCC after surgical resection has seldom been reported. Here, we describe a case of multiple seeding metastases in the abdomen and pelvis 78 months after robot-assisted laparoscopic partial nephrectomy, without prior history of biopsy for chromophobe RCC in the right kidney. As magnetic resonance imaging (MRI) of the pelvic mass showed a similar appearance to the primary renal mass and displayed separate margins with the rectum and prostate gland, we were able to make a diagnosis before pathologic confirmation.

Classification system for partial distal biceps tendon tears: a descriptive 3-Tesla magnetic resonance imaging study of tear morphology

  • Alex B Boyle;Simon BM MacLean
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.366-372
    • /
    • 2023
  • Background: There is minimal literature on the morphology of partial distal biceps tendon (DBT) tears. We sought to investigate tear morphology by retrospectively reviewing 3-Tesla magnetic resonance imaging (3T MRI) scans of elbows with partial DBT tears and to propose a basic classification system. Methods: 3T MRI scans of elbows with partial DBT tears were retrospectively reviewed by two experienced observers. Basic demographic data were collected. Tear morphology was recorded including type, presence of retraction (>5 mm), and presence of discrete long-head and short-head tendons at the DBT insertion. Results: For analysis, 44 3T MRI scans of 44 elbows with partial DBT tears were included. There were 9 isolated long-head tears (20%), 13 isolated short-head tears (30%), 2 complete long-head tears with a partial short-head tear (5%), 5 complete short-head tears with a partial long-head tear (11%), and 15 peel-off tears (34%). Retraction was seen in 5 or 44 partial tears (11%), and 13 of the 44 DBTs were bifid tendons at the insertion (30%). Conclusions: Partial DBT tears can be classified into five sub-types: long-head isolated tears, short-head isolated tears, complete long-head tears with partial short-head involvement, complete short-head tears with partial long-head involvement, and peel-off tears. Classification of tears may have implications for operative and non-operative management. Level of evidence: III.

고압회전기 고정자 권선에서 발생하는 부분방전 진단을 위한 Sierpinski 정삼각형 프랙탈 센서 (The Design of a Regular Triangle Fractal Sensor for Partial Discharge diagnosis in High Voltage Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;공태식;김희동;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1486-1487
    • /
    • 2007
  • In case of stator windings in 6.6 kV high voltage rotary machine, the pulse resonance shows in 1.1 MHz - 2 MHz and 20 MHz - 200 MHz as the range of low frequency. Actually, the peak of partial discharge appears the range which generated resonance frequency, and is confirmed in the range of 1.1 MHz -2 MHz. In this paper, the Sierpinski triangle fractal sensor have designed by using the CST MWS for confirming the partial discharge in 20 MHz - 200 MHz. As a result, we have obtained the result that the resonance pulse freqency is correlated with the partial discharge freqency in 20 MHz - 200 MHz.

  • PDF

부분기여도함수를 이용한 전술차량 소음원 분석 (Noise-source Analysis of Tactical Vehicle Using Partial Coherence Function)

  • 박성호;이경현;한형석;전수홍
    • 한국소음진동공학회논문집
    • /
    • 제26권7호
    • /
    • pp.774-780
    • /
    • 2016
  • In this paper noise source and transfer path of tactical vehicle are analyzed with partial coherence function and spectrum analysis. Engine, transmission, structure panel and aerodynamic are main source of cabin noise. To reduce cabin noise, identifying transfer path of sources and analyzing their contribution is important. With modeling of transfer path and partial coherence function, transfer path and principal noise source can be identified. Engine/transmission and structural resonance are principal source of low frequency noise and by adding stiffener and sound absorbing material, resonance of vibration and inflow air problem can be solved.

유체가 채워진 실린더형 공동에 의한 탄성파 공명 산란 해석 (Elastic Wave Resonance Scattering from a Fluid-filled Cylindrical Cavity)

  • Huinam Rhee;Park, Youngjin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.208-213
    • /
    • 2002
  • A new method is presented for the isolation of resonances from scattered waves for elastic wave resonance scattering problems. The resonance scattering function consisting purely of resonance information is defined. Elastic wave resonance scattering from a water-filled cylindrical cavity imbedded in an aluminum matrix is numerically analyzed. The classical resonance scattering theory and the new method compute different magnitudes and phases of the resonances from each partial wave, and therefore. their total resonance spectra are quite different. The exact $\pi$ - radians phase shifts through the resonance and anti-resonance frequencies show that the proposed method properly extracts the vibrational resonance information of the scatterer compared to resonance scattering theory.

  • PDF

부분적인 상태궤환과 공진비제어를 이용한 2관성계의 H제어 (H control of 2-mass system using partial state feedback and resonance ratio control)

  • 김진수;유상봉
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.36-44
    • /
    • 2003
  • 전동기와 부하가 강성이 작은 축으로 연결되는 산업용 전동기 구동시스템에 있어서 전동기의 관성과 부하의 관성에 의해 축에 비틀림 진동이 발생한다. 이러한 문제를 해결하기 위하여 기존에 2자유도 H$_{\infty}$제어기가 제안되었다. 그러나 이 제어기는 구현하는데 어려움이 있다. 본 논문에서는 부분적인 상태궤환과 공진비제어를 이용한 2관성계의 H$_{\infty}$제어가 제안되었다. 제안된 제어기는 간단하면서도 외란 및 진동억제 성능을 만족한다.어기는 간단하면서도 외란 및 진동억제 성능을 만족한다.

원통형 유체 산란체에 의한 공명 산란 탄성파의 진폭 및 위상 해석 (Analysis of Modulus and Phase of Resonance Scattered Elastic Waves from Cylindrical Fluid Scatterers)

  • 임현준;홍기석;김정태
    • 한국음향학회지
    • /
    • 제20권4호
    • /
    • pp.62-70
    • /
    • 2001
  • 최근 개발된 탄성파 공명산란이론에 기초하여, 원통형 유체산란체, 원통형 구멍 및 공명산란체의 문제에서 초음파탐촉자로 측정할 수 있는 응력 성분간 관계식을 유도하였다. 계산된 공명산란 응력부분파는 산란계수와 유사한 주파수 거동을 보이는데, 특히 공명주파수 근처에서 180°의 급격한 위상변화를 보인다. 유체 매질내 압력의 주파수 거동도 고찰함으로써, 탄성파 공명산란이론에 대한 이해를 증진하였다. 본 논문에서 연구되고 개발된 방법을 사용하면, 탄성매질 내의 유체개재물에 대한 비파괴평가의 신뢰성이 더욱 향상될 것이다.