배전변압기용 절연지의 전기적 특성 (Electrical Characteristics of Insulation Paper for Distribution Transformers)

  • 정종욱;송일근;이병성;한재홍;권동진;김찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.1-5
    • /
    • 2001
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material of distribution transformers. The relative permittivities(dielectric constants) and $tan{\delta}$(dielectric dissipation factors) were measured as a dielectric characteristic and the partial discharge inception voltages(PDIVs) and breakdown voltages were also measured as an electrical strength characteristic of Nomex paper. As a result, the permittivity and $tan{\delta}$ of Nomex paper showed temperature and frequency dependency. Especially, the permittivity of 0.18mm Nomex paper was 2.4 according to the ASTM condition. And the PDIVs and breakdown voltages were, almost linearly increased with the thickness of Nomex paper and its electrical strength was better than conventional kraft paper.

  • PDF

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

다중해상도 분해에 의한 부분방전 신호의 특징에 관한 연구 (A Study on the Characteristics of Partial Discharge Signal by Multiresolution Decomposition)

  • 이현동;김충년;이광식;이동인;최상태;이동헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1924-1926
    • /
    • 2000
  • This paper deals with the multiresolution analysis of wavelet transform for partial discharge(PD).PD is an electrical discharge that only partically bridges the insulation performance of electrical equipment in high voltage. PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise. In recently, wavelet transform has become a powerful tool to analysis and process signals in various science and technology fields. In this paper, daubechies family is adopted for the research of the characteristics of PD signals. The results show that the kurtosis is increased with discharge process and skewness is decreased with discharge process, but when PD occured positive range then skewness is increased. Segment 7, 8, 9, 10, 11 values is increased with discharge process, so phase distribution is characterized by 210$\sim$330 ranges.

  • PDF

고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구 (A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD))

  • 김지홍;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

전력용 케이블 시편에서 전기트리 발생원에 따른 부분방전 분포 특성 및 발생원 분류기법 비교 (Analysis of PD Distribution Characteristics and Comparison of Classification Methods according to Electrical Tree Source in Power Cable)

  • 박성희;정해은;임기조;강성화
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.57-64
    • /
    • 2007
  • One of the cause of insulation failure in power cable is well known by electrical treeing discharge. This is occurred for imposed continuous stress at cable. And this event is related to safety, reliability and maintenance. In this paper, throughout analysis of partial discharge(PD) distribution when occurring the electrical tree, is studied for the purpose of knowing of electrical treeing discharge characteristics according to defects. Own characteristic of tree will be differently processed in each defect and this reason is the first purpose of this paper. To acquire PD data, three defective tree models were made. And their own data is shown by the phase-resolved partial discharge method (PRPD). As a result of PRPD, tree discharge sources have their own characteristics. And if other defects (void, metal particle) exist internal power cable then their characteristics are shown very different. This result Is related to the time of breakdown and this is importance of cable diagnosis. And classification method of PD sources was studied in this paper. It needs select the most useful method to apply PD data classification one of the proposed method. To meet the requirement, we select methods of different type. That is, neural network(NN-BP), adaptive neuro-fuzzy inference system and PCA-LDA were applied to result. As a result of, ANFIS shows the highest rate which value is 98 %. Generally, PCA-LDA and ANFIS are better than BP. Finally, we performed classification of tree progress using ANFIS and that result is 92 %.

SF6 가스 중 직류 고전압 하에서 부분방전 특성 (Characteristics of Partial Discharge Under HVDC in SF6 Gas)

  • 김민수;김선재;정기우;조향은;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.238-243
    • /
    • 2014
  • This paper dealt with the measurement and analysis of partial discharge (PD) under high voltage direct current (HVDC) in SF6 gas. Electrode systems such as a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack on epoxy plate and a free particle (FP) were fabricated to simulate the insulation defects. The analysis system was designed with a Time-Frequency (T-F) map algorithm programed based on LabVIEW. This can arrange the acquired PD pulses into frequency and time domain. A HVDC power source is composed of a transformer (220 V/50 kV), a diode (100 kV) and a capacitor (50 kV, 0.5 ${\mu}F$). The gap between the electrodes is 3 mm, and the $SF_6$ gas was set at 5 bar. PD pulses were detected by a 50 ${\Omega}$ non-inductive resistor. In the analysis, PD pulses were distributed below 0.5 MHz and 20 ns ~ 35 ns for the POC, 0.7 MHz ~ 1.7 MHz, below 0.6 MHz and 10 ns ~ 40 ns and 60 ns ~125 ns for the POE, below 0.1 MHz and 135 ns ~ 215 ns for the crack, and below 1.6 MHz and 250 ns for the FP.

점화코일용 에폭시의 부분방전 특성 (Partial Discharge Characteristics of Epoxy for Ignition Coil)

  • 신종열;홍진웅
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.141-149
    • /
    • 2004
  • 가솔린 엔진을 장착한 자동차는 고전압발생장치인 점화코일을 이용하여 고전압을 발생 연소실 내의 혼합기를 점화 및 연소시킴으로써 동력을 얻고 엔진을 구동하게 된다. 점화코일은 1차측 낮은 전압을 스위칭 작용으로 2차측 높은 전압을 발생시키고, 이를 전극으로 보내는데, 점화코일에 작은 결함이 발생하게 되면 제 성능을 발휘하지 못한다. 본 연구에서는 현재 사용하고 있는 에폭시 성형 점화코일과 절연재료인 에폭시수지를 시료로 선택하여 시료에 전압이 인가될 때 발생하는 부분방전 특성을 측정하여 전압변화에 따른 위상각, 방전전하량 및 발생빈도 수 등의 분포를 연구하고 검토한 결과를 실제 자동차점화장치에 접목시켜 점화코일의 성능향상과 전기장치의 신뢰성 확보에 기여하고자 한다.

SF6 가스절연에서 부분방전의 특성분석 (Analysis of Partial Discharge Characteristics in SF6 Gas Insulation)

  • 김선재;왕국명;박서준;길경석;안창환
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

침 전극 기울기에 따른 XLPE의 부분 방전 특성 (The Partial Discharge Characteristics of the XLPE According to the Tilt of the Needle Electrode)

  • 신종열;안병철;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.28-33
    • /
    • 2015
  • The needle electrode is inserted into the cross-linked polyethylene(XLPE) which is the ultra high voltage cable for electric power. By changing the tilt of the needle electrode, we investigated how the void and the thickness of the insulating layer influence the partial discharge(PD) characteristics and the insulating breakdown. In order to investigate the PD characteristics, The XLPE cable was used to the specimens and the tungsten electrode was used with the needle electrode. And the inner semi-conductive layer material of XLPE cable was used with the negative electrode by bonding with the use of conduction tape. The size of the specimens was manufactured to be $16{\times}40{\times}30[mm^3]$. We confirmed the effect on changing the PD characteristics according to the changing voltage and the tilt of the electrode after applying the voltage on the electrode from 1[kV] to 40[kV] at room temperature. In the PD characteristics, it was confirmed that the PD current of air void specimens with tilt was unstable more than that of no void specimens with tilt. It was also confirmed that the breakdown voltage was decreased because the effect of air void is more active than the change of the needle electrode tilt in the specimen with air void inside the insulation.

AE(Acoustic Emission) 센서를 이용한 오차에 강인한 부분방전 위치추정 알고리즘에 관한 연구 (A Study on Algorithm Robust to Error for Estimating partial Discharge Location using Acoustic Emission Sensors)

  • 조성민;신희상;김재철;이양진;김광화
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.69-75
    • /
    • 2008
  • 본 논문에서는 오차에 강인하게 초음파센서를 이용한 부분방전 위치를 추정하는 알고리즘을 제시하였다. 변압기 내부는 유온이 균일하지 않기 때문에 초음파의 절연유에서 전달 속도를 정확하게 산정하기 힘들다. 그렇기 때문에 처리 과정에서 일정 오차가 발생하게 된다. 따라서 점검자에게 유용한 정보를 제공하기 위해 부분방전의 위치추정 알고리즘은 이런 오차를 충분히 반영하여야 한다. 기존의 위치추정 기법은 좌표로 부분방전 발생 위치를 나타내었지만 본 논문에서 제시하는 Lookup-Table(LUT)를 이용한 기법은 부분방전 발생 위치를 지도형태로 나타내도록하여 점검자에게 충분히 유용한 정보를 제공할 수 있도록 하였다. 또한 임의로 데이터에 오차를 일으켜 기존 기법과 제시한 기법의 성능을 비교하였다.