• Title/Summary/Keyword: Partial discharge source

Search Result 98, Processing Time 0.034 seconds

On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring (UHF 기술을 이용한 온라인 부분방전 모니터링)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

Effects of the ESD Protection Performance on GPNS(Gate to Primary N+ diffusion Space) Variation in the NSCR_PPS Device (NSCR_PPS 소자에서 게이트와 N+ 확산층 간격의 변화가 정전기 보호성능에 미치는 영향)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.6-11
    • /
    • 2015
  • The ESD(electrostatic discharge) protection performance of PPS(PMOS pass structure) embedded N-type silicon controlled rectifier(NSCR_PPS) device with different GPNS(Gate to Primary $N^+$ Diffusion Space) structure was discussed for high voltage I/O applications. A conventional NSCR_PPS standard device with FPW(Full P-Well) structure and non-CPS(Counter Pocket Source) implant shows typical SCR-like characteristics with low on-resistance(Ron), low snapback holding voltage(Vh) and low thermal breakdown voltage(Vtb), which may cause latch-up problem during normal operation. However, our proposed NSCR_PPS devices with modified PPW(Partial P-Well) structure and optimal CPS implant demonstrate the improved ESD protection performance as a function of GPNS variation. GPNS was a important parameter, which is satisfied design window of ESD protection device.

Partial Discharges Detection for MV Cables using Non-conventional Sensors (Non-conventional 센서를 이용한 MV급 전력케이블의 부분방전 측정)

  • Kim, Jong-Yeol;Lee, Young-Jo;Cho, Sung-Joo;Nam, Jung-Hak;Koo, Ja-Yoon;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1604-1605
    • /
    • 2011
  • This paper deals with the partial discharge detection in order to recognize with three different nature of artificial defects using non-conventional HF-VHF PD sensor of which two measuring position are chosen along the 22.9kV XLPE power cable specimen. The response of the sensor under investigation has been observed be significantly affected by the cable length from the PD sources. As a result, it seems that the detecting sensor position is very important for the analysis of the nature of PD source. Moreover, it could be suggested that any standardized calibration method should be established replacing IEC 60270 as far as any type of non-conventional sensors are concerned.

  • PDF

A Study on Characteristics of Sagnac Interferometric Optical Fiber Sensor to Pulsed Ultrasonic Signal in Underwater (수중에서 펄스초음파 신호에 대한 Sagnac 간섭형 광섬유센서의 특성 연구)

  • 이준호;신대용
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • In this paper, we present the fabrication and characteristic analysis of Sagnac interferometric optical fiber senior(OFS) system for detecting pulsed ultrasonic signal in underwater. The hollow cylindrical mandrel wound round by single mode optical fiber is used as sensing component. The ultrasonic signal source is simulated by the PZT actuator operated by an function generator. The distance dependency of the OFS's sensitivity was measured. The sensitivity has been shown to be inversely propotional to the square-root of distance between ultrasonic source and sensing component. It has also been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor. and accurate location of ultrasonic signal could be carried out using two OFSs.

Analysis of ultrasonic signals through media in transformer (변압기의 전달 매질에 따른 초음파 신호의 특성 분석)

  • Chin, Sang-Bum;Park, Hyun-Soo;Shin, Dong-Seok;Kwak, Hee-Ro;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2057-2059
    • /
    • 1999
  • This paper describes the phenomena of the refraction and reflection when the ultrasonic signals generated by PD(Partial Discharge) in a transformer propagate through the boundary between insulating oil and the tank of the transformer. In this paper, considering the characteristic of the ultrasonic signal and the velocity of the propagation in medium, propagation time from PD source to sensor for incidence angle was calculated. As a result, it was found that the shortest time at specific angle exists. Taking into account the velocity of the propagation in medium, the shortest time with a computer was simulated. It was shown that the simulation was same as experimental result at a real PD source in the transformer.

  • PDF

Investigation Between Gas in Oil Analysis and the Source of Trouble in Transformer (변압기 절연유 가스분석과 고장원인 검토)

  • Kweon Dong-Jin;Kwak Joo-Sik;Eun Jong-Young;Min Byeong-Moon;Yu Dong-Gyon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.343-349
    • /
    • 2005
  • The gas in oil analysis of transformer is the most widely used technology for diagnosis of transformer in the world. It has brought excellent results to prevention of transformer failure. The criteria for maintenance and judgement, however, is still required continuous supplement to improve the accuracy of the diagnosis on the basis of accumulated data of gas analysis and investigations in the transformer In this study, the relationship between the detection rate of the defects and the source of troubles are analyzed according to the investigation in the transformer, which was conducted by KEPCO in 2004. As a result, the validity of the criteria being used at present was examined thoroughly.

Main-stream Partial Nitritation - Anammox (PN/A) Processes for Energy-efficient Short-cut Nitrogen Removal (주공정에서 아질산화-혐기성 암모늄 산화법에 의한 단축질소제거공정 연구동향)

  • Park, Hongkeun;Rhu, Daehwan
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.96-108
    • /
    • 2018
  • Large efforts have recently been made on research and development of sustainable and energy-efficient short-cut nitrogen removal processes owing to strong attention to the energy neutral/positive wastewater treatment system. Anaerobic ammonium oxidizing bacteria (anammox bacteria) have been highlighted since 1990's due to their unique advantages including 60% less energy consumption, nearly 100% reduction for carbon source requirement, and 80% less sludge production. Side-stream short-cut nitrogen removal using anammox bacteria and partial nitritation anammox (PN/A) has been well established, whereas substantial challenges remain to be addressed mainly due to undesired main-stream conditions for anammox bacteria. These include low temperature, low concentrations of ammonia, nitrite, free ammonia, free nitrous acid or a combination of those. In addition, an anammox side-stream nitrogen management is insufficient to reduce overall energy consumption for energy-neutral or energy positive water resource recovery facility (WRRF) and at the same time to comply with nitrogen discharge regulation. This implies the development of the successful main-stream anammox based technology will accelerate a conversion of current wastewater treatment plants to sustainable water and energy recovery facility. This study discusses the status of the research, key mechanisms & interactions of the protagonists in the main-stream PN/A, and control parameters and major challenges in process development.

Partial Purification of Antioxidative Peptides from Gelatin Hydrolysates of Alaska Pollock Surimi Refiner Discharge

  • Heu, Min-Soo;Park, Chan-Ho;Kim, Hyung-Jun;Park, Jae-W.;Kim, Jin-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.249-257
    • /
    • 2009
  • This study is conducted to partially purify an antioxidative peptide in a two-step gelatin hydrolysate from Alaska pollock surimi refiner discharge, which was obtained by sequential treatment with Pronase E and Flavourzyme. The two-step gelatin hydrolysate was fractionated using chromatographic methods. Based on the same protein concentration of each fraction, the antioxidative activities (85.1-95.4%) of positive fractions fractionated by ion-exchange chromatography were higher than those (27.2-87.8%) from gel filtration. Then, further purification of the positive fractions was performed. Among them, the partially purified A1C1L2G1 and A1C1L2G2 fractions showed 96.2% and 85.1% inhibition, respectively, of linoleic acid peroxidation. The A1C1L2G1 fraction was composed of 15 kinds of amino acids and the predominant amino acids were proline, glycine and alanine. The results obtained in this study suggested that the fraction partially purified through chromatographic methods from the two-step gelatin hydrolysate of Alaska pollock surimi refiner discharge could be useful as a supplementary source for improving health functionality.

A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery (고압 전기설비 부분방전시험을 위한 노이즈 저감방안)

  • Lee, Young-Jun;Park, Kwang-Ha;Choi, Hyung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF

Production of Hydrogen from Methane Using a 3 Phase AC Glidarc Discharge (3상 교류 부채꼴 방전을 이용한 메탄으로부터 수소 생산)

  • Kim, Seong-Cheon;Chun, Young-Nam
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • Popular techniques for producing synthesis gas by converting methane include steam reforming and catalyst reforming. However, these are high temperature and high pressure processes limited by equipment, cost and difficulty of operation. Low temperature plasma is projected to be a technique that can be used to produce high concentration hydrogen from methane. It is suitable for miniaturization and for application in other technologies. In this research, the effect of changing each of the following variables was studied using an AC Glidarc system that was conceived by the research team: the gas components ratio, the gas flow rate, the catalyst reactor temperature and voltage. Glidarc plasma reformer was consisted of 3 electrodes and an AC power source. And air was added for the partial oxidation reaction of methane. The result showed that as the gas flow rate, the catalyst reactor temperature and the electric power increased, the methane conversion rate and the hydrogen concentration also increased. With $O_2/C$ ratio of 0.45, input flow rate of 4.9 l/min and power supply of 1 kW as the reference condition, the methane conversion rate, the high hydrogen selectivity and the reformer energy density were 69.2%, 36.2% and 35.2% respectively.