• Title/Summary/Keyword: Partial Repair

Search Result 214, Processing Time 0.029 seconds

Atypically Large Calcific Tendinitis of the Shoulder: A Case Report

  • Kim, Jin Wan;Moon, Kyu Pill;Kim, Kyung Taek;Hwang, Youn Soo;Park, Won Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.241-244
    • /
    • 2016
  • Calcific tendinitis of the shoulder joint is common disease causing acute pain, mainly involving the supraspinatus or infraspinatus muscle, and less frequently the teres minor or subscapularis muscle. This study reports on the satisfactory arthroscopic removal of calcium deposits as well as infraspinatus and supraspinatus muscle repair without relapse via minimal incision using suture anchors. This was a case of atypically extensive calcific tendinitis involving the infraspinatus muscle, with a bursal side partial rupture of the supraspinatus muscle in a 61-year-old female whose chief complaint was chronic pain of the right shoulder exacerbated by limited movement.

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Mirror Image Gerbode or Partial Atrioventricular Canal Defect?

  • Ariturk, Cem;Gullu, Ahmet Umit;Senay, Sahin;Okten, Eyup Murat;Toraman, Fevzi;Karabulut, E. Hasan;Melengic, Letisya;Alhan, Cem
    • Journal of Chest Surgery
    • /
    • v.48 no.6
    • /
    • pp.404-406
    • /
    • 2015
  • Gebode defect, that can accurately be treated surgical repair, is defined as a true communication between left ventricle and right atrium. A 74-year-old woman with a worsening history of ortophnea and peripheral edema was hospitalised. A communication between right atrium and left ventricle was diagnosed using transeusophageal echocardiography. The defect was repaired and mitral valve was replaced with a biologic valve. It would be beter to tailor surgical strategy for each case with atrioventricular canal defect after preoperative transeusophageal echocardiography and peroperative direct sight.

A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer (가스분석을 이용한 전력용 변압기 이상진단 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

Implant Restorations Using Fiber Reinforced Framework (Fiber Reinforced Framework를 이용한 Implant 수복증례)

  • Song, Ho-Yong;Lee, Yang-Jin;Jo, Ri-Ra
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.10 no.2
    • /
    • pp.21-30
    • /
    • 2001
  • Fiber reinforced materials have favorable mechanical properties. Moreover, the strength to weight ratios of this material is superior to those of most alloys. Comparing to the metals, it showed many other advantages as well, including non-corrosiveness, translucency and easy repair characteristic. Since, it has the potential for the chair-side and laboratory fabrication, it is not surprising that fiber reinforced composites offer the potential for use in various applications in dentistry. To make the well-fitted restorations, Fiber reinforced composite (FRC) has been suggested as an alternative framework material for the implant supported fixed prosthesis. Two fixed partial denture fabrication procedures were tried. Vectris fiber was pressed to the EsthetiCone gold cylinder on the implant positioned cast. And then, Targis were added on it. In the other method, we used the customized component using UCLA abutment. The beads for retaining the Vectris fiber were added on the abutment. If careful laboratory and clinical techniques were done, these two techniques would fulfill the demands of the esthetics and strength.

  • PDF

The development of the Switchgear Insulation Deterioration Condition Monitoring Equipment by using RFCT (RFCT를 이용한 개폐기 절연열화 상태감시 진단 장치 개발)

  • Choi, Jae-Ok;Kim, Young-Noh;Hwang, Kyung-Jun;Jung, In-Song;Park, Hak-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.404-405
    • /
    • 2008
  • This paper is analyzed that the development of intelligent terminal unit for the switchgear partial discharge diagnosis. It is the core technology for supplying with stable and trust electric as a technology that be economic of the high efficient, the maintain, the confidence and the repair. So the condition diagnosis of the switchgear is necessary by developing inteligent terminal unit.

  • PDF

Partial Mandibulectomy for Oral Cavity and Oropharyngeal Carcinoma (구강 및 구인두암의 수술에 있어서 하악골 부분절제술에 대한 고찰)

  • Choi Eun-Chang;Hong Won-Pyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.10 no.2
    • /
    • pp.163-170
    • /
    • 1994
  • Segmental mandibulectomy causes severe functional disability and cosmetic problem. Many methods of reconstruction have been used but none of these procedures provides the ideal solution. There has been increased interest in the possibility of preserving a portion of the mandible and still carrying out a adequate tumor resection. We experienced four cases of marginal with sagittal mandibulectomy in patients with floor of mouth. buccal. and soft palate carcinoma, and sagittal mandibulectomy in 8 patients with tonsillar carcinoma and a case of marginal mandibulectomy in tonsillar cancer patient. In all cases mandible facing the tumor were successfully resected and repair of the mandible. postoperative facial contour were satisfactory. We think. that these sagittal procedures are oncologically sound in its removal of tumor. biomechanically secure and maximize postoperative rehabilitation while maintaining the normal contour of the face.

  • PDF

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

The Standardized Methods for Improvement of Maintenance and Performance Construction of Deterioration caused by Fire damage (화재피해 콘크리트의 유지관리 및 시공성능 향상을 위한 표준화방안)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.16-18
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement (회전자 고정자권선의 절연보수후 절연특성변화 연구)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF