• Title/Summary/Keyword: Partial Discharge(PD)

Search Result 502, Processing Time 0.03 seconds

Dismantled PD diagnosis on 6.6kV Stator Winding by Using Spiral Patch Antenna Sensor (분리된 6.6kV급 고정자 권선의 부분방전 측정을 위한 Spiral 패치 안테나 센서 적용 연구)

  • Lwin, Kyaw Soe;Shin, Dong-Hoon;Lim, Kwang-Jin;Yang, Hoon;Kong, Tae-Sik;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.211-212
    • /
    • 2007
  • There have three kinds of partial discharge diagnosis testing: online, offline and dismantled testing on high voltage rotating machine. Our lab testing is dismantled testing, taking off pieces into individual parts of stator coil of high voltage rotating machine in laboratory. We investigate internal discharge, slot discharge, corona discharge and normal state on pre-made stator winding by using spiral patch antenna sensor. In this lab test we compare the experimental results of our spiral patch antenna sensor and reference commercial HFCT sensor.

  • PDF

Development of External UHF PD Sensor for the Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear (가스절연 개폐장치의 PD검출용 UHF 대역 외장형 센서 제작 및 감도 특성)

  • Lee, Chang-R.;Hong, C.Y.;Choi, B.H.;Yoon, J.H.;Nam, G.C.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1799-1801
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the electromagnetic waves up to ultra high frequency (UHF) bands, propagating in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the external PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

A Study on Pattern Characteristics of Multi-Defect Partial Discharge (다중결함 부분방전의 패턴특성 연구)

  • Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.970-972
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produces from these defect simultaneously. Regarding these situations, we have to discriminate the type of defect as well as to determine whether the PD occurs or not. In our research. some analysis results of the PD signals from multi-defects insulating system will be presented. We measure the PD signals using three kind of electrode system: IEC(b). Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combine two electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods will be tested, and the possibilities and limitations of each method will be clarified.

  • PDF

A study on the correlation between the PD pattern and the formation of electrical trees by use of XLPE insulation for the underground power transmission cable (송전 XLPE 케이블 절연층을 이용한 전기트리 형성과 부분방전 양상의 상관관계)

  • Lee, J.S.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2051-2053
    • /
    • 1999
  • In this work, PD patterns and electrical trees are observed by use of the XLPE cable insulation. and the tree initiation voltage related to the contamination are also measured in order to calculate the electric stress necessary for the design of cable insulation. Throughout these works, correlation between the PD pattern and the shape of electrical tree has been observed that there may exist three distinct pattern of PD dependence on the stage of tree propagation, Such correlation could bring a basic information in connection with the partial discharge of cable system. It was also found that the electrical stress necessary for the initiation of electrical tree was measured to the 290kV/mm for the 154kV XLPE cables manufactured in KOREA.

  • PDF

Analysis PD Pattern in PET film with semiconductor particle (반도전 입자를 갖는 PET film내에서의 PD Pattern 분석)

  • Choi, Pil-Moon;Jeong, Byung-Sun;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2399-2401
    • /
    • 1999
  • This paper indicate that phase resolved partial discharge pattern are investigated on PET films with semiconductor particle. In this study, we measured phase-resolved PD pattern and statistical parameter from PET specimens according to containing semiconductor particle. Measurement system is the conventional PD detector using digital signal processing technique. The relationship of semiconductor particle in PET film was discussed through the difference of $\psi$-q-n distribution and statistical analysis.

  • PDF

A Study on the Partial Discharge Patterns from Multi-Defect Insulating Systems

  • Lee, June-Ho;Tatsuki Okamoto
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.170-173
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produced from these defects simultaneously. Regarding these situations, we have to discriminate the type of defect as well as determine whether the PD occurs or not. In this paper, some analysis results of the PD signals from multi-defects insulating system were presented. We measure the PD signals by using three kind of electrode system, IEC(b), Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combined to electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods were tried, and the possibilities and limitations of each method were clarified.

  • PDF

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear Using External UHF PD sensors (가스절연기기에서 외장형 PD 센서를 이용한 부분방전 검출)

  • Lee, Chang-R.;Hong, C.Y.;Choi, B.H.;Yoon, J.H.;Nam, G.C.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.125-127
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the ultra high frequency (UHF) signals in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • Yang, Sang-Hyeon;Park, No-Jun;Kim, Chung-Sik;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Insulation Characteristics of High Temperature Superconducting Cable (고온 초전도 레이블의 절연 특성)

  • Kim, H.J.;Kim, J.H.;Sim, K.D.;Kim, H.J.;Cho, J.W.;Seong, K.C.;Kwag, D.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF