• Title/Summary/Keyword: ParkingLot

Search Result 432, Processing Time 0.023 seconds

Smart Parking Guidance System based on IoT Car-stoppers (IoT 카스토퍼 기반 스마트 주차안내 시스템)

  • Shim, Dongha;Yang, Ji-Hoon;Son, Jeungki;Han, Seung-Han;Lee, Hyounmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • This paper presents a smart parking guidance system based on IoT car-stoppers. The car-stopper embedding an IoT sensor module has the advantage of easy installation compared to conventional parking sensors buried in ground. The parking status data are transferred to the IoT gateway by the sequential point-to-point communication between the car-stoppers. The data transferred from the IoT gateway are stored in the web server, and parking spaces can be monitored remotely through the Android app in a smart device. An active/sleep cycle method using a watch dog timer is employed to reduce the power consumption of the battery powered car-stopper. The power consumption of the car-stopper is measured to be 80 and 25 mW at the active and sleep mode, respectively. A configuration of ultra-low-power IoT sensor module is proposed to minimize the power consumption in the sleep mode. The operation of the implemented system has been verified in a real-world parking lot.

Detection of Car Accidents in Parking Lots (주차장 환경에서의 차량 사고 검출)

  • Jeong, Woo Jin;Lee, Jong Min;Park, Ki Tae;Moon, Young Shik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.147-153
    • /
    • 2015
  • We propose a detecting method for a car accident in parking lots. The proposed method consists of 3 parts : car detection, car tracking, and accident detection. In the car detection part, we detect the car using the pixel based foreground extraction method and the motion map. From the result of the car detection, the moving car is tracked. In the accident detection part, we set the accident detecting region in front of car, and then the car accident is detected using the difference of the motion. Experimental results show that the proposed method effectively detects the car accident in the parking lots.

Optimum Location Choice for Bike Parking Lots Using Heuristic P-Median Algorithm (휴리스틱 P-Median 알고리즘을 이용한 자전거주차장 최적입지선정)

  • Park, Bora;Lee, Kyu Jin;Choi, Keechoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1989-1998
    • /
    • 2013
  • As the importance of 'bike revitalization' has been emphasized in our society, many cities around the world put enormous efforts to create a bike-oriented transportation system. None the less, the results were not much productive and effective. In this study, to decide the location and number of the bike-parking facilities, the heuristic P-median algorithm has been applied with and without budget constraints. A test network with 30 candidate locations (centroids) were employed. The results show that the optimum number of bike parking lots with and without the budget limits are 9 and 20, respectively. Since the optimum locations determined in this study were congruous with the actual bike parking lots with high utilization rates, it is expected that the proposed methods can be applied for determining the optimum locations of the bike parking facilities elsewhere. Some limitations and future research agenda have also been discussed.

A Study on the Change of Architecture Density and Residential Environment according to Reconstruction (재건축에 따른 건축밀도 및 주거환경의 변화 연구)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

A Study on the Loss Reduction Method of Reinforcing Bar through Case Study

  • Park, U-Yeol;Jung, Hyeon-Ok;Kang, Tai-Kyung;Cho, Hun-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.123-132
    • /
    • 2010
  • Rebar work accounts for approximately 30% of the total construction costs for rebars and concrete. Recently, the high rising prices of rebars have become one of the principle factors of rising construction costs. Therefore, construction companies are putting much effort into loss reduction of rebars. Consequently, in this study, we wished to present loss reduction methods of rebars before the preparation of the placing drawings. To devise such methods, we collected previous case studies and analyzed methods that were applied for loss reduction. As a result of the analysis, we were able to find the following methods for loss reduction of rebars: method of reducing the number of splices at the mat foundation, method of reducing splice length at the internal columns or walls of the underground parking lot, method of reducing cap-ties of internal beams of basement floors excluding perimeter beams, and method of reducing anchorage length at the internal column or wall of the underground parking lot. Based on those analysis results, we presented our own loss reduction methods of rebars. Applying our methods resulted in considerable loss reduction.

Fuzzy Logic Based Sound Source Localization System Using Sound Strength in the Underground Parking Lot (지하주차장에서 음의 세기를 이용한 퍼지로직 기반 음원 위치추정 시스템)

  • Choi, Chang Yong;Lee, Dong Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.434-439
    • /
    • 2013
  • It is very difficult to monitor the blind spots that are not recognized by traditional surveillance camera (CCTV) systems, and the surveillance efficiencies are very low though many accidents/events can be solved by the systems. In this paper, the fuzzy logic based sound source localization system using sound strength in the underground parking lot is suggested and the performance of the system is analyzed in order to enhance the stabilization and the accuracy of the localization algorithm in the suggested system. It is confirmed that the localization stabilization of the localization algorithm (SLA_fuzzy) using the fuzzy logic in the suggested system is 4 times higher than that of the conventional localization algorithm (SLA). In addition to this, the localization accuracy of the SLA_fuzzy in the suggested system is 29% higher than that of the SLA.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.